Skip to content

Fluke

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.

Electricians, HVAC/R technicians, plant engineers and power quality consultants involved in the maintenance, service and design of every type of residential, industrial, plant and commercial building use Fluke professional test tools. 


  • $347.70

    Fluke Multimeter For Electricians, Model 117

    Fluke
    Description The Fluke 117 Electricians Multimeter is a compact, CAT III 600 V, True-rms meter that includes an easy-to-use interface with a bright backlight for darker worksites. It saves you time and enables you to move from job to job more quickly. With a quick turn of the dial you can get measurements for: Resistance Continuity Frequency Capacitance Min/Max/Average A digital multimeter designed to be hauled everywhere with you, part of your everyday tools. The 117 is built for demanding applications like: Commercial buildings Hospitals Schools Keep yourself safer with integrated VoltAlert™ technology. Fast, go/no go non-contact voltage detection built into your multimeter saves you from having to carry around or find an extra tool to get the work started. Set the dial and get your measurement quickly with AutoVolt. This automatic AC/DC voltage selector makes it easier for you to get the measurement you need and move on quicker. What's in the box: Fluke 117 Digital Multimeter (1 pair) 4 mm silicone test lead set Holster Quick reference guide Features Compact, true-rms digital multimeter for electricians Includes multimeter, 4mm silicone test leads, holster and manual Integrated non-contact voltage detection keeps you safe Prevent false readings from ghost voltage with selectable low-impedance mode Technical Information Specifications Maximum voltage between any terminal and earth ground 600 V Safety IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293) Display Digital: 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Battery type 9 volt Alkaline, IEC 6LR61 Battery life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range/resolution 600.0 mV / 0.1 mV Accuracy ±([% of reading] + [counts]): 0.5% + 2 DC volts Range/resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V Accuracy ±([% of reading] + [counts]): 0.5% + 2 Auto volts Range/resolution 600.0 V / 0.1 V Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) AC millivolts¹ True RMS Range/resolution 600.0 mV / 0.1 mV Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) AC volts¹ True RMS Range/resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) Continuity Range/resolution 600 Ω / 1 Ω Accuracy Beeper on 250 Ω detects opens or shorts of 500 μs or longer. Ohms Range/resolution 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ Accuracy 0.9% + 1 Range/resolution 40.00 MΩ / 0.01 MΩ Accuracy 5% + 2 Diode test Range/resolution 2.00 V / 0.001 V Accuracy 0.9% + 2 Capacitance Range/resolution 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF Accuracy 1.9% + 2 Range/resolution > 1000 μF Accuracy 5% + 20% Lo-Z capacitance Range 1 nF to 500 μF Accuracy 10% + 2 typical AC amps True RMS (45 Hz to 500 Hz) Range/resolution 6.000 A / 0.001 A 10.00 A / 0.01 A Accuracy 1.5% + 3 20 A continuous overload for 30 seconds max DC amps Range/resolution 6.000 A / 0.001 A 10.00 A / 0.01 A Accuracy 1.0% + 3 20 A continuous overload for 30 seconds max Hz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz Accuracy 0.1% + 2 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. Mechanical and General Specifications Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) Weight 550 g Warranty 3 years Document User's Manual
    • In stock
    • Free shipping