Description Klein Tools CL800 is an automatically ranging true root mean squared (TRMS) digital clamp meter that measures AC/DC voltage, resistance, continuity, frequency, capacitance, and test diodes via test-leads, and temperature via a thermocouple probe. It also features a Low Impedance (LoZ) mode for identifying and eliminating ghost or stray voltages. Benefits Automatically ranging true mean squared (TRMS) technology for increased accuracy Test leads measure AC/DC voltage, resistance, continuity, frequency and capacitance and tests diodes Thermocouple probe measures temperature Low Impedance (LoZ) mode for identifying and eliminating ghost or stray voltages CAT IV 600V, CAT III 1000V, Class 2, Double insulation safety rating Built to withstand a 6.6-foot (2m) drop Low battery indicator and easily accessible battery compartment Operating temp: 32-degree F to 104-degree F (0-degree C to 40-degree C) Operating altitude to 6562-Foot (2000m) Meets requirements for use in basic and controlled electromagnetic environments like residential, office and light-industrial locations Included: Carrying Case, 41'' (1041.4 mm) Test Leads, Thermocouple with Adapter, and Batteries Technical Information Application: Measures Current Features: Features Low Battery Indicator and Auto Shut Off Batteries: 2 x AAA Jaw Size: 1.38'' (3.5 cm) Drop Protection: 6.6' (2 m) Display: 6000 Count LCD Functions: Test leads measure AC/DC voltage, resistance, continuity, frequency and capacitance, and test diodes. Thermocouple probe measures temperature. Voltage: 1000V AC; 1000V DC Frequency: 1Hz - 500 KHz Current: 600A AC; 600A DC Capacitance: 6000µF Ohms (Resistance): 60MO Temperature Range: -14° - 1000°F (-26° - 538°C) Ingress Protection: IP40 Standard: CAT IV 600V; CE Certified Overall Length: 9.09'' (23.1 cm) Overall Height: 1.55'' (3.9 cm) Overall Width: 3.81'' (9.7 cm) Weight: 12.5 oz (354 g) Documents CL800 - Digital Clamp Meter Instruction Manual Klein Tools CL800 Catalog
Description The CL120VP Electrical Test Kit from Klein Tools is designed with optimum reliability and safety in mind. Kit comes with 1 meter and 3 testers for a variety of applications and all stored within a convenient padded pouch. The CL120 is an AC auto-ranging 400 Amp AC/DC digital clamp meter. The RT210 Receptacle Tester detects common wiring problems for Standard and GFCI AC electrical outlets. The NCVT-3P is a dual range non-contact tester with flashlight for a broad variety of voltage applications from 12 to 1000V AC or 70 to 1000V AC. Test AC and DC voltage at four commonly used ranges with the ET40 Voltage Tester. Features CL120 Clamp Meter measure AC current via the clamp, and AC/DC voltage, resistance and continuity via test leads Meter has backlit LCD for ease of viewing in low light and is CAT III 600V, Class 2 Double Insulated RT210 detects the most common wiring problems in standard and GFCI receptacles A convenient chart on RT210 helps determine wiring conditions: open ground, reverse polarity, open hot, open neutral, and hot/ground reversed NCVT-3P has dual-range capabilities to detect from 12 to 1000V AC or 70 to 1000V AC for a broad variety of low-voltage or standard voltage applications Bright flashlight illuminates work area and may be used independent of NCVT-3P voltage detection function ET40 tests AC voltages from 12V to 240V AC at four useful levels aligned with commonly used residential voltages ET40 also tests DC voltages from 1.5V to greater than 17V to 24V at four common levels Technical Information Type: Auto Ranging Clamp Application: Testing and Measuring Voltage Special Features: Clamp Meter is Automatic Ranging for Measurement and has NCVT feature Overall Length: 8.5'' (21.5 cm) Overall Height: 1.5'' (3.8 cm) Overall Width: 3.5'' (8.9 cm) Material: ABS/Electronics Batteries: CL120: 3 x AAA; NCVT3-P: 2 x AAA; ET40: 2 x AAA Jaw Size: 1.6'' (4.1 cm) Drop Protection: 6.6' (2 m) Display: 2000 Count Backlit LCD Functions: AC Current, NCVT, AC/DC Voltage, Resistance and Continuity Voltage: 600V AC/DC Pollution Degree: 2 Standard: CATIII 600V, Class 2, Double Insulation Safety Rating, CE Certified Included: CL120 Digital Clamp Meter with Test Leads; NCVT3P Dual Range Non-Contact Voltage Tester with Flashlight; ET40 Electronic AC/DC Voltage Tester; RT210 GFCI Receptacle Tester; Carrying Case; Instructions; and All Required Batteries Weight: 11 oz (314 g) Document CL120VP Brochure NCVT-3P Brochure Clamp Meter Selection Guide CL120 Manual NCVT-3P Manual ET40 and RT210 Manual
Description The CL900 is an auto-ranging, true root mean square (TRMS) digital clamp meter that measures AC/DC current via the clamp and measures AC/DC voltage, resistance, continuity, frequency, duty-cycle, capacitance, and tests diodes via test-leads. It features a Low Impedance (LoZ) mode for identifying and eliminating ghost or stray voltages and has a dedicated mode for capturing Inrush Current. Benefits Digital Clamp Meter measures 2000A AC/DC, 1000V AC/DC, 60 Milliohm Rugged Klein ''TOUGH METER'' industrial design stands up to job site demands; built to withstand a 6.6-foot (2m) drop Automatically ranging True Root Mean Squared (TRMS) measurement technology for accuracy CAT IV 600V, CAT III 1000V, Class 2, double insulation safety rating Backlit display for clear visibility in environments with low ambient lighting Dedicated mode for capturing Inrush Current Non-contact voltage tester integrated into the clamp Low impedance (LoZ) mode for identifying and eliminating ghost or stray voltages Audible continuity, capacitance, diode test, frequency and duty cycle, min/max feature, data hold capability Test leads measure AC/DC voltage, resistance, continuity, frequency, duty-cycle, capacitance, and diodes Clamp measures AC and DC current Powers off automatically after 30 minutes of non-use to conserve battery life Low battery indicator and easily accessible battery compartment Includes carrying case, instruction manual, straight input test leads, and 2 x AAA batteries Technical Information Brand: Klein Tools Application: Measures Current to 2000A AC/DC Material: Plastic/ Electronics Batteries: 2 x AAA Auto Power-off: Yes Jaw Size: 2" (5 cm) Drop Protection: 6.6' (2 m) Display: 6000 Count LCD Functions: Audible Continuity, Capacitance, Diode Test, Frequency & Duty Cycle, Min/Max feature, Data Hold capability, Inrush Current, Low Impedance AC/DC Voltage: 1000V Frequency: 500kHz Current: 2000A AC/DC Capacitance: 6000 µF Ohms (Resistance): 60MΩ DC Polarity Indicator: Yes DC Micro-Amp: No Ingress Protection: IP40 Standard: CAT IV 600V, CAT III 1000V Overall Length: 10.39'' (26.4 cm) Overall Height: 1.70'' (4.3 cm) Overall Width: 3.90'' (9.9 cm) Documents CL900 Digital Clamp Meter Specification sheet CL900 Instruction Manual Safety Data sheet
Description Klein Tools CL320 is an automatically ranging true root mean square (TRMS) digital clamp meter that measures AC current via the clamp, AC/DC voltage, DC microamps, resistance, continuity, frequency, capacitance, and tests diodes via test-leads, and temperature via a thermocouple probe. Benefits Clamp Meter with automatically ranging true mean squared (TRMS) technology for increased accuracy Measures AC current via the clamp and AC/DC voltage, DC microamps, resistance, continuity, frequency, capacitance and test diodes via the test leads Thermocouple probe measures temperature Built to withstand a 6.6-foot (2 m) drop CAT III 600V, Class 2, Double insulation safety rating Backlit display for clear readings Powers off automatically after 15 minutes of non-use to conserve battery life Includes a carrying case, test leads, and 3 x AAA batteries Low battery indicator and easily accessible battery compartment Meets requirements for use in basic and controlled electromagnetic environments like residential, office and light-industrial locations Included: Carrying Case, 41'' (1041.4 mm) Test Leads, Thermocouple with Adapter, and Batteries Technical Information Application: Measures AC Current, DC micro-Amp current Functions: AC current, AC/DC voltage, DC micro-Amps, resistance, continuity, frequency, capacitance and test diodes. Material: ABS Batteries: 3 x AAA Auto-Power Off: Yes Jaw Size: 1.12'' (2.9 cm) Drop Protection: 3.3' (1 m) Display: 4000 Count LCD Voltage: 600V AC; 600V DC Frequency: 10Hz - 1 MHz Current: 400A AC Capacitance: 4000µF Ohms (Resistance): 40MΩ AC Voltage: 600 DC Voltage: 600 DC Polarity Indicator: Yes DC Micro-Amp: 200 μA Temperature Range: -40° to 1832°F (-40° to 1000°C) Standard: CAT III 600V; CE Certified Overall Length: 8.7'' (22.1 cm) Overall Height: 1.61'' (4.1 cm) Overall Width: 3.02'' (7.7 cm) Weight: 10.1 oz (286 g) Documents Brochure Instruction Manual
Description Klein Tools CL700 Electrical Tester is an automatically ranging true root mean squared (TRMS) digital clamp meter that measures AC current via the clamp, and measures AC/DC voltage, resistance, continuity, frequency, capacitance, and tests diodes via test-leads, and temperature via a thermocouple probe. It also features a Low Impedance (LoZ) mode for identifying and eliminating ghost or stray voltages. Klein Tools’ Test and Measurement product line was exclusively designed from the ground up by electricians for electricians. Years of field research, combined with extensive input from electricians across America, inspired the development of meters loaded with innovative, time-saving features. Benefits Clamp Meter with automatically ranging true mean squared (TRMS) technology for increased accuracy Electronic Tester's clamp measures AC current and its thermocouple probe measures temperature Test leads measure AC/DC voltage, resistance, continuity, frequency and capacitance and tests diodes Low Impedance (LoZ) mode for identifying and eliminating ghost or stray voltages CAT IV 600V, CAT III 1000V, Class 2, Double insulation safety rating Built to withstand a 6.6-Foot (2 m) drop Low battery indicator and easily accessible battery compartment Includes a carrying pouch, test leads, thermocouple with adapter and batteries Meets requirements for use in basic and controlled electromagnetic environments like residential, office and light-industrial locations Operating Temperature: 32-degrees F to 104-degrees F (0-degrees C to 40-degrees C) Operating altitude to 6562-Foot (2000 m) Technical Information Application: Measures AC Current Special Features: Features Low Battery Indicator Batteries: 2 x AAA Jaw Size: 1.38'' (3.5 cm) Drop Protection: 6.6' (2 m) Display: 6000 Count LCD Functions: Clamp measures AC current and thermocouple probe measures temperature. Test leads measure AC/DC voltage, resistance, continuity, frequency and capacitance and tests diodes Voltage: 1000V AC; 1000V DC Frequency: 1Hz - 500 KHz Current: 600A Capacitance: 6000µF Ohms (Resistance): 60MO Temperature Range: -14° - 1000°F (-26° - 538°C) Ingress Protection: IP40 Standard: CAT IV 600V; CE Certified Included: Carrying Case, Test Leads, Thermocouple with Adapter, and Batteries Overall Length: 9.09'' (23.1 cm) Overall Height: 1.55'' (3.9 cm) Overall Width: 3.81'' (9.7 cm) Weight: 11.8 oz (336 g) Document Clamp Meter Selection Guide Instructions Safety Data Sheet
Description Klein Tools CL445 Clamp Meter is an advanced HVAC clamp meter with automatically ranging true root mean square (TRMS) for maximum accuracy. The meter measures AC current, inrush current, AC/DC voltage, DC microamps, resistance, continuity, frequency, capacitance, temperature, diodes, and more. This Digital Clamp Meter can simultaneously measure current and voltage, has a built-in worklight and comes with right-angle input test leads, push-on alligator clips, K-Type thermocouple, storage pouch, instructional manual, and 3 x AAA batteries. Features CL445 HVAC Clamp Meter is an automatically ranging true root mean square (TRMS) digital clamp meter Digital clamp measures 600 A AC current and inrush current Test leads measure 750V AC/600V DC voltage, DC micro amp, resistance, continuity, frequency, duty-cycle, capacitance, and diode tests K-Type thermocouple port for measuring temperature from -148 to 1832-Degree Fahrenheit (-100 to 1000-Degree Celsius) Detect AC current with non-contact voltage tester integrated into the clamp jaw Backlit LCD with dual V + A function allows simultaneous viewing of voltage and current measurements Dedicated mode for capturing DC micro amp and inrush current Meter has a built-in worklight to illuminate in low light areas CAT IV 600V, CAT III 750V, Class 2, Double insulation safety rating Includes right-angle input test leads, push-on alligator clips, K-type thermocouple, storage pouch, instruction manual, and 3 x AAA batteries Can be used with Magnetic Hanger (Cat. No. 69417, sold separately) for hands free operation Technical Information Type: HVAC TRMS Clamp Meter Application: Measures AC Current, Inrush Current, AC/DC Voltage, DC Microamps, Resistance, Continuity, Frequency, Capacitance, Temperature, Diodes, and More Special Features: Automatically Ranging True Root Mean Squared (TRMS) Measurement Technology for Accuracy; NCVT; V + A Simultaneously Displayed; Built-in Worklight Material: ABS/Electronics Batteries: 3 x AAA Auto-Power Off: Yes Jaw Size: 1.25'' (3.2 cm) Drop Protection: 6.6' (2 m) Display: 6000 Count LCD Functions: TRMS, AC Current, Inrush Current, AC/DC Voltage, DC Microamps, Resistance, Audible Continuity, Frequency, AC Voltage + AC Amperage, Capacitance, Temperature, Non-Contact Voltage Testing, Diodes, Min/Max, Data Hold Capability Voltage: 750V AC; 600V DC Frequency: 60 kHz Current: 600A Capacitance: 6.000mF Ohms (Resistance): 60MΩ AC Voltage: 750V DC Voltage: 600V DC Polarity Indicator: Yes DC Micro-Amp: 600µA Temperature Range: -148° to 1832°F (-100° to 1000°C) Standard: CAT IV 600V, CAT III 750V, Class 2, Double Insulation Safety Rating Included: Clamp Meter; Right-Angle Input Test Leads; Push-On Alligator Clips; K-Type Thermocouple; Storage Pouch; Instruction Manual; and 3 x AAA Batteries Overall Length: 9.24'' (23.5 cm) Overall Height: 1.59'' (4 cm) Overall Width: 3.77'' (9.6 cm) Weight: 12.5 oz (355 g) Document Brochure User's Manual
Description The Fluke 378 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display. It includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, the 378 FC will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem. The included iFlex flexible current probe lets you measure ac current as high as 2500 A. Crowded wiring cabinets and large conductors are easily measured with the iFlex probe. Your job will get easier when you use the 378 FC clamp meter. The display turns green when a stable FieldSense measurement is detected. Visual Continuity also provides a bright green screen for easy detection of continuity in noisy work areas. Features Measure voltage and current with your clamp jaw Faster, safer testing - all without touching a live wire - using FieldSense™ technology Power quality indicator shows whether equipment or power line is faulty Complete 3-phase voltage and current tests in 3 quick steps Values are displayed on your smart phone and saved to the cloud via Fluke Connect software Phase rotation auto-calculated and shown on the Fluke Connect software No more hand-written notes or complicated math. Technical Information General specifications General Maximum Voltage between any Terminal and Earth Ground 1000 V Battery Type 2 AA IEC LR6 alkaline Life 200 hour Display Dual readout Automatic Power Off 20 minutes Electrical AC Current: Jaw Range 999.9 A Resolution 0.1 A Accuracy 2 % ±5 digits (45 Hz to 66 Hz) Crest Factor (50/60 Hz) 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2 % for C.F. >2 AC Current: Flexible Current Probe Range 2500 A Resolution 1 A (≤2500 A) 0.1 A (≤999.9 A) Accuracy 3 % ±5 digits (5 Hz to 500 Hz) Crest Factor (50/60Hz) 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2 % for C.F. >2 Position Sensitivity Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5 % B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0 % C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 999.9 A Resolution 0.1 A Accuracy 2 % ±5 digits 1 [1] When using the ZERO function to compensate for offsets AC Voltage: Field Sense Range 1000 V Resolution 1 V (≤1000V) Accuracy ≤4/0 AWG 3 % ±5 digits (45 Hz to 66 Hz) ≥4/0 AWG 5 % ±5 digits (45 Hz to 66 Hz) Position wire as close as possible to jaw opening (see illustration). AC Voltage: Test Leads Range 600.0 V 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1 % ±5 digits (20 Hz to 500 Hz) DC Voltage Range 600.0 V 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1 % ±5 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1 % ±5 digits Amps Frequency: Jaw Range 45 Hz to 66 Hz Resolution 0.1 Hz Accuracy 0.5 % ±5 digits Trigger Level 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥ 5 A 100 Hz to 500 Hz, ≥ 10 A Amps Frequency: Flexible Current Probe Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5 % ±5 digits Trigger Level 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz,≥25 A Resistance Range 60.00 kΩ 6000 Ω 600.0 Ω Resolution 0.1 Ω (≤600.0 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60.00 kΩ) Accuracy 1 % ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤100.0 μF) 1 μF (≤1000 μF) Accuracy 1 % ±4 digits Mechanical Size (L x W x H) 274 mm x 86 mm x 47 mm Weight (with Batteries) 463 g Jaw Opening 34 mm Flexible Current Probe Diameter 7.5 mm Flexible Current Probe Cable Length (head to electronics connector) 1.8 m Rogowski Coil Length 450 mm Environmental Operating Temperature -10 °C to 50 °C Storage Temperature -40 °C to 60 °C Operating Humidity (without condensation) Non condensing (28 °C or <18 °C Ingress Protection IEC 60529: IP30 (jaw closed) Operating Altitude 2000 m Storage Altitude 12 000 m Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2, CISPR 11: Group 1, Class B Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Safety General IEC 61010-1: Pollution degree 2 Measurement IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V Current Clamp for Leakage Current Measurements IEC 61557-13: Class 2, ≤30 A/m Wireless Radio Radio Frequency Certification FCC ID: T68-FBLE IC:6627A-FBLE Frequency Range 2405 MHz to 2480 MHz Output Power <100 mW Radio Frequency Data Radio Frequency Data For Class A Devices SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU. The full text of the EU declaration is available at the following internet address: https://dam-assets.fluke.com/s3fs-public/FLK_RED_1aeng0900.pdf . Document User's manual Quick Reference
Description The Fluke 323 clamp meter is a good basic troubleshooting tool for commercial and residential electricians. It includes True RMS measurements, optimized ergonomics, and large display for efficient troubleshooting. It's designed to perform in the toughest environments and provide noise-free, reliable results, so you can trust it to help you confidently diagnose problems almost anywhere. Use it to verify the presence of load current, AC voltage, and continuity of circuits, switches, fuses and contacts. Its slim, compact size and rugged design make it well suited for measuring current up to 400 A in tight cable compartments. The Fluke 323 comes with a two-year warranty and a soft carrying case. Features Rugged, reliable basic True-RMS clamp meter for measuring current up to 400 A Measures AC current to 400 A Measures AC voltage and DC voltage to 600 V Provides True RMS AC voltage and current for accurate measurements on non-linear signals Measures resistance to 4 kΩ with continuity detection Features slim, ergonomic design for measuring in tight cable compartments Presents measurements on a large, easy-to-read display Hold function captures a reading on the display Features a CAT III 600 V, CAT IV 300 V safety rating Comes with a two-year warranty and soft carrying case Technical Information Specifications AC current Range 400.0 A Accuracy 2% ± 5 digits (45 Hz to 65 Hz) 2.5% ± 5 digits (65 Hz to 400 Hz) DC current Range - Accuracy - AC voltage Range 600.0 V Accuracy 1.5% ± 5 digits DC voltage Range 600.0 V Accuracy 1.0% ± 5 digits Resistance Range 400.0 Ω/ 4000 Ω Accuracy 1.0% ± 5 digits Continuity ≤ 70 Ω Capacitance - Frequency - AC response True-RMS Backlight - Data hold Yes Contact temperature - Min/Max - Size H x W x D (mm) 207 x 75 x 34 Max wire diameter 30 mm (600 MCM) Weight 265 g Category rating CAT III 600 V CAT IV 300 V Warranty Two-year Document User's Manual Quick Reference Brochure
Description Klein Tools CL390 is an automatically ranging true root mean squared (TRMS) digital clamp meter. It measures AC/DC current and NCVT via the clamp, AC/DC voltage, DC microamps, resistance, continuity, frequency, capacitance, and diodes via test leads, and temperature via a thermocouple probe. It features a high visibility, reverse contrast LCD display that optimizes view ability both in dark or bright ambient lighting. Features Test lead holder on side of clamp and optional magnetic hanger for meter (Cat. Nos. 69445 or 69417) for hands free operation Non-contact voltage tester integrated into the clamp jaw High-visibility reverse contrast LCD display for improved view ability in all ambient lighting conditions Automatically ranging True Root Mean Squared (TRMS) measurement technology for accuracy Measures AC/DC current and NCVT via clamp and AC/DC voltage, resistance, frequency, DC microamps, capacitance, duty cycle, diode test, and continuity via test-leads, and temperature with thermocouple Measures temperature with a K-Type thermocouple probe Max/Min, Rel/Zero and Data Hold capability Auto-power off after 10 minutes to conserve battery life Includes a carrying case, test leads with CAT III/CAT IV safety caps, thermocouple, instructions, and 3 x AAA batteries Low battery indicator and easily accessible battery compartment Built to withstand a 6.6-Foot (2 m) drop CAT III 600V, Class 2, Double insulation safety rating Meets requirements for use in basic and controlled electromagnetic environments like residential, office and light-industrial locations Technical Information Type: AC/DC Current TRMS Clamp Application: Measures both AC/DC current and NCVT via the clamp and AC/DC voltage, DC microamp current, resistance, continuity, frequency, duty-cycle, capacitance and tests diodes via the test leads, and temperature with thermocouple Special Features: Automatically Ranging True Root Mean Squared (TRMS) Measurement Technology for Accuracy; AC/DC Current Measurement; High Visibility Reverse Contrast LCD; NCVT Material: ABS/Electronics Batteries: 3 x AAA Auto-Power Off: Yes Jaw Size: 1.6'' (4.1 cm) Drop Protection: 6.6' (2 m) Display: 4000 Count Reverse Contrast LCD Functions: TRMS, AC/DC Current, NCVT, AC/DC Voltage, Resistance, DC microamp, Frequency, Capacitance, Continuity, Duty Cycle, Diode Test, and Temperature Voltage: 600 V AC/DC Frequency: 10 Hz to 60 kHz for 8 V to 220 V AC RMS Current: 400 A AC/DC Capacitance: 4000 µF Ohms (Resistance): 40 MΩ AC Voltage: 600 V DC Voltage: 600 V DC Polarity Indicator: Yes DC Micro-Amp: 200 µA Temperature Range: -40° - 1832°F (-40° - 1000°C) Standard: CATIII 600V, Class 2, Double Insulation Safety Rating, CE Certified Included: Clamp Meter; Carrying Case; Instructions; Test Leads; Thermocouple; Batteries Overall Length: 8.45'' (21.5 cm) Overall Height: 1.5'' (3.8 cm) Overall Width: 3.5'' (8.9 cm) Weight: 11 oz (314 g) Document Brochure Instruction Clamp Meter Selection Guide
Description The Fluke 902 FC Clamp Meter, with Fluke Connect wireless connectivity, can help HVAC technicians improve productivity in the field. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to perform many essential HVAC system measurements: microamps for testing pilot light sensors; resistance up to 60 kΩ; AC current and AC/DC voltage; capacitance; and contact temperature, all with just one tool. Plus its small form factor makes it easy to hang on to and navigate in tight work spaces. As part of the Fluke Connect family, the 902 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. No need to write down the results. Trend and monitor measurements live on your phone screen, and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email, and collaborate in real time with other colleagues with ShareLive™ video calls or email. The 902 FC can also decrease the frequency of wearing personal protective equipment (PPE) when working on high voltage/current panels. Simply turn off the panel. Verify that it is de-energized using standard safety procedures. Place the clamp and synch it to a smartphone. Close the panel, reenergize it, and take measurements from a safe distance. What's in the box: 902 FC Clamp Meter (1 pair) TL75 test leads 80BK integrated DMM temperature probe 2 AA Alkaline Batteries (Installed) Soft carrying case Quick Reference Guide Features A wireless Fluke Connect®-enabled clamp meter designed specifically for the needs of HVAC technicians Offers 200 µA DC current measurements to measure flame rod Extends resistance range to measure thermistors up to 60kΩ Captures flue gas temperature Measures start and run motor capacitors Measures variable frequency drive performance Ergonomic design fits in your hand and can be used while wearing personal protective equipment Large, easy-to-read backlit display improves readings in low light settings Connects to your smartphone via Fluke Connect so you can read measurements at a safer distance Measures AC current to 600 A and AC and DC voltage to 600 V Measures capacitance to 1000 µF and DC current to 200 µA Measures temperature from -10 °C to 400 °C (14 °F to 752 °F) Offers True-RMS voltage and current measurements to accurately measure non-linear signals Measures resistance to 60 kΩ Offers Min/Max recording to capture variations automatically Runs on two AA alkaline batteries Technical Information Function A ac (via Jaw) Resolution 0.1 A Accuracy 2.0% ±5 digit (45-65 Hz) 2.5% ±5 digit (65-400 Hz) Range 600.0 A Crest Factor (50Hz or 60Hz) 2.5 MIN@220 A > 1.4 MIN@600 A Add 2% for CF>400 A V ac Resolution 0.1 V Accuracy 1.5% ±5 digits Range 600.0 V V dc Resolution 0.1 V Accuracy 1.5% ±5 digits Range 600.0 V Ohms Resolution 0.1/1/10 Accuracy 1% ±5 digits Range 600/6000/60.00 kΩ Capacitance Resolution 0.1/1 µF Accuracy 1% ±4 digits Range 100.0/1000 µF µA Resolution 0.1 µA Accuracy 1% ±5 digits Range 200 µA Contact temperature Resolution 0.1 C/F Accuracy 1% ±8 digits Range -40 to 400 °C (-40 °F to 752 °F) Continuity beeper Beeper volume 75 dBA nom. 15 cm. from case front On threshold <=30 Ω Mechanical and General Specifications Maximum voltage between any terminal and earth ground 1000 V Battery type 2 AA alkaline batteries, NEDA 15A, IEC LR6 Temperature Operating: -10 °C to +50 °C (14 °F to +122 °F) Storage: -40 °C to +60 °C (-40 °F to +140 °F) Operating humidity Non condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) Altitude Operating: 3,000 m (9,842 ft) Storage: 12,000 m (39,370 ft) Dimensions 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in) Weight (meter only) 419 g (15 oz) Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V IP Rating IEC 60529: IP30, non-operating Radio Frequency Certification FCC ID:T68-FBLE IC:6627A-FBLE Electromagnetic Compatibility (EMC) International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Temperature coefficients Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C Document User's Manual
Description The CL220VP Premium Meter Electrical Test Kit from Klein Tools is designed with optimum reliability and safety in mind. Kit comes with 1 clamp meter and 3 testers for a variety of applications and all stored within a convenient padded pouch. The CL220 is an auto-ranging 400 Amp clamp meter that measures AC current, AC/DC voltage, and temperature. The NCVT3P is a dual range non-contact tester with an integrated flashlight for a broad variety of voltage applications from 12 to 1000V AC or 70 to 1000V AC. Test AC and DC voltage at four commonly used ranges with the ET40 Voltage Tester. The RT210 Receptacle Tester detects common wiring problems for Standard and GFCI AC electrical outlets. Features CL220 Clamp Meter measures AC current and AC/DC voltage, resistance, and continuity via test leads, and temperature with thermocouple Auto-ranging TRMS meter has a backlit LCD on clamp to provide better viewing in low light and is CAT III 600V, Class 2 Double Insulated NCVT3P has dual-range capabilities to detect from 12 to 1000V AC or 70 to 1000V AC for a broad variety of low-voltage or standard voltage applications Bright flashlight illuminates work area and may be used independent of NCVT-3P voltage detection function ET40 tests AC voltages from 12V to 240V and DC voltages from 1.5V to >17V to 24V at four useful levels aligned with commonly used residential voltages ET40 also has built-in test lead holders spaced for testing tamper-resistant US-style outlets and convenient for storage RT210 detects common wiring problems in standard and GFCI receptacles: open ground, reverse polarity, open hot, open neutral, and hot/ground reversed Technical Information Type: Electrical Test Kit Application: Testing and Measuring AC/DC Voltage, Resistance, Continuity, Temperature, Non-contact Voltage Detection, and Determining Wiring Conditions in Outlets Special Features: CL220: Automatically Ranging True Root Mean Squared (TRMS) Measurement Technology for Accuracy; NCVT; Added Temperature Overall Length: 8.45'' (21.5 cm) Overall Height: 1.5'' (3.8 cm) Overall Width: 3.5'' (8.9 cm) Material: ABS/Electronics Batteries: CL220: 3 x AAA; NCVT3P: 2 x AAA; ET40: 2 x AAA Jaw Size: CL220: 1.6'' (4.1 cm) Drop Protection: 6.6' (2 m) Display: CL220: 2000 Count Backlit LCD Functions: Clamp Meter: TRMS, AC Current, NCVT, AC/DC Voltage, Resistance, Continuity and Temperature Voltage: CL220: 600 V AC/DC; NCVT3P: Range 1: 12 -1000V AC; Range 2: 70 - 1000V AC; ET40: AC Level Indicators: 12V, 24V, 120V, 240V and DC Indicators: 1.5V, 9V, 12V, >17-24V; RT310: 120V AC in 3-Wire Grounded Electrical Outlet Pollution Degree: CL220: 2 Standard: CL220: CATIII 600V, Class 2, Double Insulation Safety Rating, CE and UKCA Certified Included: CL220 Digital Clamp Meter with Test Leads; NCVT3P Dual Range Non-Contact Voltage Tester with Flashlight; ET40 Electronic AC/DC Voltage Tester; RT210 GFCI Receptacle Tester; Carrying Case; Instructions; and All Required Batteries Weight: 11 oz (314 g) Document CL220 Manual NCVT-3P Manual ET40 & RT210 Manual
Description Klein Tools CL120 Clamp Meter is an automatically ranging digital clamp-meter that measures AC current and NCVT via the clamp, and AC/DC voltage, resistance and continuity via test-leads. Klein Tools’ Test and Measurement product line was exclusively designed from the ground up by electricians for electricians. Years of field research, combined with extensive input from electricians across America, inspired the development of meters and electrical testers loaded with time-saving features. Features Clamp Meter measures AC current and NCVT via clamp and AC/DC voltage, resistance and continuity via test-leads Non-contact voltage tester integrated into the clamp jaw Backlit LCD for ease of viewing in low light Auto ranging measurements Test lead holder on side of clamp and optional magnetic hanger for meter (Cat. Nos. 69445 or 69417) for hands-free operation Durable, multifunction meter Auto-Range, Hold, Data Hold, and Max value Auto-power off after 10 minutes to conserve battery life Includes a carrying case, test leads with CAT III/CAT IV safety caps, Instructions, and 3 x AAA batteries Low battery indicator and easily accessible battery compartment Built to withstand a 6.6-Foot (2 m) drop CAT III 600V, Class 2, Double insulation safety rating Meets requirements for use in basic and controlled electromagnetic environments like residential, office and light-industrial locations Technical Information Type: Auto Ranging Clamp Application: Measures AC Current and NCVT via Clamp and AC/DC Voltage, Resistance, and Continuity via Test-Leads Special Features: Automatic Ranging for Measurement; NCVT Material: ABS/Electronics Batteries: 3 x AAA Auto-Power Off: Yes Jaw Size: 1.6'' (4.1 cm) Drop Protection: 6.6' (2 m) Display: 2000 Count Backlit LCD Functions: AC Current, NCVT, AC/DC Voltage, Resistance and Continuity Voltage: 600V AC/DC Current: 400 A AC Ohms (Resistance): 20MO AC Voltage: 600V DC Voltage: 600V DC Polarity Indicator: Yes Accuracy: +/-1.0 + 3 digits Standard: CATIII 600V, Class 2, Double Insulation Safety Rating, CE Certified Included: Clamp Meter; Carrying Case; Instructions; Test Leads; and Batteries Overall Length: 8.45'' (21.5 cm) Overall Height: 1.5'' (3.8 cm) Overall Width: 3.5'' (8.9 cm) Weight: 11 oz (314 g) Document Brochure Instructions Clamp Meter Selection Guide
Description The IDEAL 61-757 TightSight ™ Clamp Meter is a CAT IV 600 CAT III 1000 V rated auto ranging true root mean square (TRMS) digital clamp meter that measures up to 600 Amps AC and DC current via the clamp head. It measures up to 1000V AC and DC, Low Impedance AC Voltage (Lo Z) (to reduce the possibility of false readings due to ghost voltages) , frequency, resistance, continuity, capacitance, and diodes via test-leads (included) and measures temperature (⁰F/⁰C) via a K-Type thermocouple (included). It's capable of detecting the presence of voltage between 40V to 600V via a non-contact sensor in the right tip of the clamp. The patented TightSight LCD Display, located on the bottom of the unit, enhances safety and productivity by displaying a secondary reading at the end of the meter, eliminating the need to bend or twist conductors or place you head near the panel in order to see the main meter display. Both displays can be backlit, and a built-in flashlight can be illuminated when working in poor or zero lighting conditions. The unit uses an illuminated red LED in the center of the meter and emits audible tones to notify when voltage is above 30 volts, when continuity is detected and when the NCV senses voltage within its set range. The clamp head has a built-in probe tip holder on the backside of the right clamp to allow measurements holding the clamp in one hand and the second lead in the other hand. The meter has a hanging strap mount (compatible with all other IDEAL meters with this feature) that allows for a hanging strap (sold separately) to be attached to the meter so it can be hung from a nail, screw or magnetic surface. An industrial grade over molding enhances grip and drop protection. This meter features HOLD, MIN/MAX, Relative, Zero, Range, and selectable Auto Power Off functions. The meter comes with 3 1.5V AAA Batteries and an easy open, fully accessible storage pouch with a belt loop that allows for meter, probe and thermocouple storage. Features UL Certified CAT IV 600 CAT III 1000V, measures 0-600 Amps AC/DC and 0-1000 Volts AC/DC Patented TightSight Display eliminates the need to bend or twist conductors or place your head near or in the panel and allows you to easily read the bottom display when taking measurements Provides True RMS AC voltage and current for accurate measurements on non-linear signals Measures AC/DC Current, AC/DC Voltage, frequency, resistance, continuity, capacitance, diodes, temperature, Low Impedance AC Voltage (Lo Z) (to reduce the possibility of false readings due to ghost voltages), and senses AC voltage. Built-in probe tip holder and hanging strap clip allows safer, easier measurement Built-in Flashlight and dual backlit displays, allow for safer/faster work in poorly lit environments Over molded Industrial design enhances gripping and allows the meter to withstand a 6.6-foot (2 m) drop Includes soft case, test leads, batteries, and K-Type Thermocouple Technical Information Certification: CAT IV 600V - CAT III 1000V Listing: cULs, CE, RCM Drop Protection: 6.6 ft (2m) Claw/Jaw Opening: 1.4 in (35.5mm) AC Voltage: 600V DC Voltage: 1000V AC Current: 600A DC Current: 600A Ohms: 60MΩ AC Millivolts: 6000 DC Millivolts: 6000 True RMS: Yes High Voltage Alarm: ACV/DCV | >30V Audible Continuity: Yes Visual Continuity: Yes Backlight: Yes Temperature: -40°F - 1835°F ( -40°C - 1000°C) Low Impedance (LoZ): Yes NCV: 40-600V Auto Ranging: Yes Range Hold: Yes Data Hold: Yes Relative: Yes Diode Test: Yes Capacitance Test: 6.000mF Frequency / Duty Cycle: 10Hz-9.999KHz Max/Min: Yes Magnetic Strap Mount: Yes Test Probe Holder: Yes Flashlight: Yes Auto-Power Off (APO): Yes APO Disable: Yes Low Battery Indication: Yes Battery Type: 3x 1.5V AAA (Included) Bottom LCD Display: Yes LCD Display Count: 6000 Warranty: 2-Year* Accessory Included: TL-757 Leads & Alligator Clips Document Lead Selection Chart Catalogue Spec sheet Instruction Warranty
Description Klein Tools HVAC Electrical Test Kit features Cat. No. CL320 Auto-Ranging, TRMS (True Root Mean Square), 400A HVAC Clamp Meter; Cat. No. IR07 Dual IR and Probe Thermometer, for both surface and air temperature measurements; and Cat. No. NCVT3P Dual Range Non-Contact Voltage Tester With Flashlight, for detection of AC voltage from 12 to 1000V with visual and audible indicators. Included is a convenient carrying pouch, test leads with CAT III/CAT IV safety caps, thermocouple, and all batteries. Features HVAC Kit with testers for the HVAC Professional: HVAC Digital Clamp Meter, Dual IR/Probe Thermometer, and Dual Range Non-Contact Voltage Tester with Flashlight Cat. No. CL320 HVAC Clamp Meter with TRMS technology measures AC current, NCVT, AC/DC voltage, resistance, frequency, DC microamps, capacitance, duty cycle, diode test, continuity, and temperature Cat. No. IR07 Dual IR Probe and Thermometer measures temperature from -40 to 572 Degrees Fahrenheit (-40 to 300 Degrees Celsius); measure surface temperature with Infrared Thermometer (DS ratio 8:1) Measure air vents and duct temperature using temperature probe with hands-free hanging hook; calculate differential temperature (T1-T2) for both IR and probe temperatures Cat. No. NCVT3P is dual-range and detects from 12 to 1000 V AC or 70 to 1000V AC for a broad variety of low-voltage or standard voltage applications Non-Contact Voltage Tester detects voltage with simultaneous visual and audible voltage indicators Bright flashlight illuminates work area and may be used independent of voltage detection function; CAT IV 1000V rating provides expanded operation and protection IR07 Thermometer is not a medical device and is NOT intended for use on people or animals Technical Information Type: HVAC Testers Application: HVAC Electrical and Temperature Testing Special Features: Cat. No. CL320: Automatically Ranging True Root Mean Squared (TRMS) Measurement Technology; CAT. No. NCVT3P: NCVT with flashlight; Cat.No. IR07 Both IR and Probe Temperature Material: ABS/Electronics Batteries: 7 x AAA Auto-Power Off: Yes Jaw Size: 1.6'' (4.1 cm) Drop Protection: 6.6' (2 m) Display: 4000 Count Backlit LCD Functions: TRMS, AC Current, NCVT, AC/DC Voltage, Resistance, DC microamp, Frequency, Capacitance, Duty Cycle, Diode Test, Continuity, and Temperature Voltage: Cat. No. CL320: 600V AC/DC; Cat. No. NCVT3P: 1000V AC Frequency: 10 Hz to1 MHz Current: 400 A AC Capacitance: 4000 µF Ohms (Resistance): 40MO AC Voltage: 600V DC Voltage: 600V DC Polarity Indicator: Yes DC Micro-Amp: 200 μA Temperature Range: -40° to 1832°F (-40° to 1000°C) Standard: Cat. No CL320: CATIII 600V, Class 2, Double Insulation Safety Rating, CE Certified; Cat. No. NCVT3P: CAT IV 1000 Included: CL320 Digital Clamp Meter with Test Leads and Thermocouple; IR07 Dual IR and Probe Thermometer; NCVT3P Dual Range Non-Contact Voltage Tester with Flashlight; Carrying Pouch; Instructions; and All Required Batteries Overall Length: 8.45'' (21.5 cm) Overall Height: 1.5'' (3.8 cm) Overall Width: 3.5'' (8.9 cm) Weight: 1.575 lb (0.7 kg) Document Brochure CL320 Instruction IR07 INstruction NCVT-3P Instruction
Description The CL220 measures AC current and NCVT via clamp and AC/DC voltage, resistance, and continuity via test-leads, and temperature with thermocouple. The meter features automatically ranging True Root Mean Squared (TRMS) measurement technology for accuracy. Additionally, a backlit LCD makes viewing in low light easy. Features Measures AC current and NCVT via clamp and AC/DC voltage, resistance, and continuity via test-leads, and temperature with thermocouple Non-contact voltage tester integrated into the clamp jaw Backlit LCD for ease of viewing in low light Automatically ranging True Root Mean Squared (TRMS) measurement technology for accuracy Test lead holder on side of clamp and optional magnetic hanger for meter (Cat. Nos. 69445 or 69417) for hands free operation Measures temperature with a K-Type thermocouple probe Auto-Range, Hold, Data Hold, and Max value Auto-power off after 10 minutes to conserve battery life Includes a carrying case, test leads with CAT III/CAT IV safety caps, thermocouple, instructions, and 3 x AAA batteries Low battery indicator and easily accessible battery compartment Built to withstand a 6.6-Foot (2 m) drop CAT III 600V, Class 2, Double insulation safety rating Meets requirements for use in basic and controlled electromagnetic environments like residential, office and light-industrial locations Technical Information Type: Auto Ranging TRMS Clamp with Temperature Application: Measures AC Current and NCVT via Clamp and AC/DC Voltage, Resistance, and Continuity via Test-leads, and Temperature with Thermocouple Special Features: Automatically Ranging True Root Mean Squared (TRMS) Measurement Technology for Accuracy; NCVT; Added Temperature Material: ABS/Electronics Batteries: 3 x AAA Auto-Power Off: Yes Jaw Size: 1.6'' (4.1 cm) Drop Protection: 6.6' (2 m) Display: 2000 Count Backlit LCD Functions: TRMS, AC Current, NCVT, AC/DC Voltage, Resistance, Continuity and Temperature Voltage: 600 V AC/DC Current: 400 A AC Ohms (Resistance): 20 MΩ AC Voltage: 600 V DC Voltage: 600 V DC Polarity Indicator: Yes Temperature Range: -40° - 1832°F (-40° - 1000°C) Standard: CATIII 600V, Class 2, Double Insulation Safety Rating, CE Certified Included: Digital Clamp Meter; Carrying Case; Instructions; Test Leads; Thermocouple; Batteries Overall Length: 8.45'' (21.5 cm) Overall Height: 1.5'' (3.8 cm) Overall Width: 3.5'' (8.9 cm) Weight: 11 oz (314 g) Document Brochure Instruction
Description Klein Tools Clamp Meter Electrical Test Kit includes the CL120 400A Auto-Ranging Digital Clamp Meter, RT210 GFCI Receptacle Tester and 69409 Line Splitter 10x. The Electrical Test Kit allows for easy testing of live circuits and measuring of current and voltage. Included is a carrying pouch, test leads and batteries. Features Measure AC current via the clamp, and AC/DC voltage, resistance and continuity via test leads Detects the most common wiring problems in standard and GFCI receptacles including open ground, reverse polarity, open hot, open neutral and hot/ground reversed Line splitter allows the measuring of current draw up to 15A without splitting the load's power cord CAT III 600V, Class 2, Double insulation safety rating AC Auto-Ranging 400 amp digital clamp meter Backlit display for clear readings Includes a case, test leads and batteries Technical Information Type: Clamp Meter Kit Application: Testing and Measuring Voltage Special Features: Backlit Display For Clear Readings Overall Length: 3.02'' (7.7 cm) Overall Height: 8.7'' (22.1 cm) Overall Width: 1.61'' (4.1 cm) Material: ABS/Electronics Batteries: 3 x AAA Jaw Size: 1.61'' (4.1 cm) Drop Protection: 6.6' (2 m) Display: 2000 Count Reverse Contrast LCD Functions: TRMS, AC Current, NCVT, AC/DC Voltage, Resistance, and Continuity Voltage: 600 V AC/DC Pollution Degree: 8.7'' (22.1 cm) Standard: CAT III 600V Included: CL120 Digital Clamp Meter with Test Leads; 69409 Line Splitter 10x; RT210 GFCI Receptacle Tester; Carrying Pouch; Instructions; and All Required Batteries Weight: 15 oz (426 g) Document Brochure Instruction
Description The Fluke 325 True-rms Clamp Meter is a reliable, versatile troubleshooting tool for commercial and residential electricians. Featuring a slim design for easy transport and use, and a large display for efficient troubleshooting. In addition to true-rms AC current and voltage on non-linear loads, the 325 measures: DC current DC voltage Temperature Frequency You’ll carry fewer tools in your bag and get more work done. The 325 gives you a strong combination of measurement functions, in a tool that is reliable, easy-to-use and affordable. This clamp meter offers True-rms AC voltage and current measurements on non-linear signals. Paired with the CAT III 600 V, CAT IV 300 V safety rating the clamp meter can also measure: Measures AC/DC current up to 400 A through jaw AC/DC voltage to 600 V using test leads Measures frequency from 5 Hz to 500 Hz; resistance to 40 kΩ Measures temperature from -10 °C to 400 °C with included K-type thermocouple Min/Max function records important values Comes with a two-year warranty Features True-rms AC/DC current, voltage, temperature, frequency Clamp meter, test leads, K-type thermocouple and soft case Versatile tool performs most front-line measurement tasks Technical Information Specifications AC current Range 40.00 A / 400.0 A Accuracy 2% ± 5 digits (45 Hz to 65 Hz) 2.5% ± 5 digits (65 Hz to 400 Hz) DC current Range 40.00 A / 400.0 A Accuracy 2% ± 5 digits AC voltage Range 600.0 V Accuracy 1.5% ± 5 digits DC voltage Range 600.0 V Accuracy 1.0% ± 5 digits Resistance Range 400.0 Ω / 4000 Ω / 40.00 kΩ Accuracy 1.0% ± 5 digits Continuity ≤ 30 Ω Capacitance 0 to 100.0 μF / 100μF to 1000 μF Frequency 5.0 Hz to 500.0 Hz AC response True-RMS Backlight Yes Data hold Yes Contact temperature -10.0°C to 400.0°C (14.0°F to 752.0°F) Min/Max Yes Size H x W x D (mm) 207 x 75 x 34 Max wire diameter 30 mm (600 MCM) Weight 283 g Category rating CAT III 600 V CAT IV 300 V Warranty Two-year Document User's Manual Quick Reference Brochure
Description Klein Tools CL600 Electrical Tester is an automatically ranging true mean squared (TRMS) digital clamp meter measures AC current via the clamp, and measures AC/DC voltage, resistance, continuity, and tests diodes via test-leads. Exclusively designed from the ground up by electricians for electricians. Years of field research, combined with extensive input from electricians across America, inspired the development of meters loaded with innovative, time-saving features. Benefits Clamp Meter with automatically ranging true mean squared (TRMS) technology for increased accuracy Amp Clamp measures AC current Test leads measure AC/DC voltage, resistance, continuity and tests diodes CAT IV 600V, CAT III 1000V, Class 2, Double insulation safety rating Built to withstand a 6.6-foot (2 m) drop Low battery indicator and easily accessible battery compartment Includes carrying pouch, test leads and batteries Operating altitude to 6,562-Foot (2,000 m) Meets requirements for use in basic and controlled electromagnetic environments like residential, office and light-industrial locations Technical Information Application: Measures AC Current Special Features: Features Low Battery Indicator Batteries: 2 x AAA Jaw Size: 1.38'' (3.5 cm) Drop Protection: 6.6' (2 m) Display: 6000 Count LCD Functions: Clamp measures AC current; Test leads measure AC/DC voltage, resistance, continuity and tests diodes Voltage: 1000V AC; 1000V DC Current: 600A Ohms (Resistance): 60MO Ingress Protection: IP40 Standard: CAT IV 600V; CE Certified Included: Carrying Case, 41'' (1041.4 mm) Test Leads and Batteries Overall Length: 9.09'' (23.1 cm) Overall Height: 1.55'' (3.9 cm) Overall Width: 3.81'' (9.7 cm) Weight: 11.8 oz (336 g) Document Clamp Meter Selection Guide Instructions Safety Data Sheet
Description Allows you to speed through startups and troubleshoot a wide range of issues, including AC+DC current and voltage, along with a three-terminal phase sequence and motor rotation testing, eliminating the need for separate testers. The AmpTip feature increases accuracy on small wires and low current, along with peak-RMS for measurement of motor in rush current. Benefits Speed through startups and troubleshoot a wide range of issues including AC+DC current and voltage Measures AC+DC current and DC microamps AC and AC+DC voltage measurements with digital filter low pass for accurate readings on variable frequency drives Also measures DC voltage, resistance, capacitance, temperature and frequency Tests continuity and diodes Three-terminal phase sequence and motor rotation testing. No need for separate testers Peak-RMS measures motor in rush current Backlight & relative mode for added versatility AmpTip increases accuracy on small wires and low current Two voltage detection modes - non-contact or using a single test lead Data hold Recording of Maximum, Minimum, and Average readings Compatible with a wide range of electrical equipment Includes: (1) Clamp Meter, (2) 1.5V AAA batteries, (1) Set of test leads and clips, (1) Carrying case Technical Information Brand: Greenlee Amperage Measurement : 60, 600 Amps AC+DC Display : LCD, 6000 Count Frequency Rating : Voltage and AmpTip™ current: 50/60 Hz. High current: 50 to 400 Hz Jaw Opening : 1.18" (30 mm) Measurement Category : CAT III 600V, CAT IV 300V Replacement Part : 02714 test leads and clips, TC-10 carrying case Resistance Measurement : 600, 6k, 60k Ohms Standard : CAT III, C/US UL Listed, CE True Power : AC+DC True RMS Voltage Measurement : 600 Volts AC+DC Documents Instruction Manual
Description Featuring simple controls and a convenient jaw clamp, this Greenlee CM-660 Digital Clamp Meter makes it easy to get accurate readings. It's designed for measuring AC current, plus AC/DC voltage, resistance and frequency. A data hold function is included. Benefits Measures AC current AC voltage measurement with digital low pass filter for accurate readings on variable frequency drives Also measures DC voltage, resistance and frequency Tests continuity and diodes AmpTip™ increases accuracy on small wires and low current Two voltage detection modes - non-contact or using a single test lead Data hold Recording of Maximum, Minimum, and Average readings Technical Information Brand: Greenlee Amperage Measurement: 60, 600 Amps AC Display: LCD, 6000 Count Frequency Rating: Voltage and AmpTip™ current: 50/60 Hz. High current: 50 to400 Hz Includes: (2) 1.5V AAA batteries, test leads, carrying case Jaw Opening: 1.18'' (30 mm) Measurement Category: CAT III 600V, CAT IV 300V Replacement Part: TSG-3 test leads, TC-10 carrying case Resistance Measurement: 600, 6k, 60k Ω Standard: CAT III, C/US UL Listed, CE True Power: AC True RMS Voltage Measurement: 600 Volts AC/DC Documents Brochure Instruction Manual
Description This clamp meter is easy to use, stand-alone, and features an 18-Inch flexible clamp that allows access into panels and hard to reach areas (bundled wires, awkward conductors, and PLC cabinets). True RMS readings with CATIV 600V or CATIII 1000V safety rating. Features backlit LCD display, auto-power off after 15 minutes, Max/Min, Hold, Auto-Ranging and Low Battery icons. Benefits Clamp meter for measuring AC current 18-Inch flexible clamp on meter enables measurements in areas that are difficult to access True RMS CAT IV 600V, CAT III 1000V meter Backlit LCD display for clear readings with 3000 count Durable, with drop protection to 6.6-feet (2 m) Auto-power off after 15 minutes of non-usage conserves battery life Low battery indicator and easily accessible battery compartment Includes Flexible AC Current Clamp Meter, instruction manual, storage pouch, 2 x AAA batteries Technical Information Type: Flexible AC Current Clamp Application: Measures AC Current Special Features: Auto-power Off, Max/Min, Hold, Auto-Ranging and Low Battery Icons Material: ABS Batteries: 2 x AAA Auto-Power Off: Yes Jaw Size: 18'' (45.7 cm) Drop Protection: 6.6' (2 m) Display: Backlit 3000 Count Functions: Auto-range, Hold, Max/Min Value, Auto-power Off Current: 0.01 to 3000A AC Standard: CATIV 600V, CATIII 1000V, Class 2 Included: Carrying Case, Instruction Manual, and 2 x AAA Batteries Overall Length: 10.50'' (26.7 cm) Overall Height: 1.06'' (2.7 cm) Overall Width: 4.12'' (10.5 cm) Weight: 5.90 oz (167.0 g) Document Brochure Instruction Manual Safety Data Sheet
Description The CL360 Electrical Tester is an automatically ranging true root mean squared (TRMS) digital open jaw fork meter that measures AC current via the fork, AC/DC voltage, continuity, and resistance via test leads. It can detect the presence of voltage via the integrated non-contact voltage (NCV) tester. It includes a carrying case, test leads and 2 x AAA batteries. Features Open Fork Meter with automatically ranging True Root Mean Squared (TRMS) measurement technology for accuracy Tester measures AC current via the clamp, and AC/DC voltage, resistance, and continuity via test leads Wide jaw for measuring current in cables up to 3/0 sizes; accommodates cables of diameter up to 0.58-Inch (1.5 cm) Non-contact voltage tester integrated into the jaw Includes a carrying case, test leads and 2 x AAA batteries Jaw and Housing: CATIV 600V/CATIII 1000V; Electrical: CATIII 600V/CATII 1000V; Class 2, Double Insulation Backlit display for clear readings Powers off automatically after 15 minutes of non-use to conserve battery life Rugged Klein TOUGH METER is built to withstand a 9.9-Foot (3m) drop Low battery indicator and easily accessible battery compartment Meets requirements for use in basic and controlled electromagnetic environments like residential, office and light-industrial locations Technical Information Type: Open Jaw Fork Current Meter Application: Measures AC Current, AC/DC Voltage, Continuity, Resistance Special Features: Low Battery Indicator, Built-in Test Lead Holders, Backlit Display Material: Plastic/Electronics Batteries: 2 x AAA Auto-Power Off: Y Jaw Size: 0.58'' (1.5 cm) Opening Drop Protection: 9.9' (3m) Display: 6000 Count LCD Functions: AC Current, AC/DC Voltage, Continuity, Resistance Voltage: 600V AC, 1000V DC Current: 200A AC Ohms (Resistance): 60MΩ AC Voltage: 600V DC Voltage: 1000V DC Polarity Indicator: Yes Ingress Protection: IP40 Standard: Jaw and Housing: CATIV 600V/CATIII 1000V; Electrical: CATIII 600V/CATII 1000V Included: Electrical Tester; Carrying Case; Instruction Manual; Straight Input Test Leads; and 2 x 1.5V AAA Batteries Overall Length: 8.39'' (21.3 cm) Overall Height: 1.38'' (3.5 cm) Overall Width: 2.12'' (5.4 cm) Weight: 6.40 oz (180.0g) Document Brochure Instruction
Description The IDEAL 61-415 TightSight Split Jaw Meter is a CAT IV 600V, CAT III 1000V auto ranging true root mean square (TRMS) digital fork meter that measures up to 200 Amps AC or DC between the forks. It measures up to 1000V AC and DC, continuity, resistance, capacitance, and diodes via test-leads (included) and detects the presence of voltage between 40V to 600V via a non-contact sensor in the tip of the right fork. The Dual large displays can be backlit, and a built-in flashlight can be illuminated when working in poor or zero lighting conditions. The unit uses an illuminated red LED in the center of the meter and emits audible tones to notify when voltage is above 30 volts, when continuity is detected and when the NCV senses voltage within its set range. The back of the meter has a built-in two position dual probe holder; the lower position allows for probe storage, the higher position allows for testing or measurement holding the meter and secured probe in one hand and the second probe in the other hand, or for both probes to be secured in the tip while conducting measurements. The meter has a hanging strap mount (compatible with all other IDEAL meters with this feature) that allows for a hanging strap (sold separately) to be attached to the meter so it can be hung from a nail, screw or magnetic surface. This meter features HOLD, MIN/MAX, Relative, Range, and selectable Auto Power Off functions. The meter comes with 3 1.5V AAA Batteries and an easy open, fully accessible storage pouch with a belt loop that allows for storage. Features UL Certified CAT IV 600V & CAT III 1000V, measures 0-200 Amps AC/DC and 0-1000 Volts AC/DC Provides True RMS AC voltage and current for accurate measurements on non-linear signals Measures AC/DC Current, AC/DC Voltage, continuity, resistance, capacitance, diodes, and senses AC voltage Built-in probe tip holder and hanging strap clip allows safer, easier measurement and probe storage Built-in Flashlight and Dual backlit displays allow for safer/faster work in poorly lit environments Includes soft case, test leads, and batteries Technical Information CAT Rating (Safety): CAT IV 600V - CAT III 1000V Listing: cULus, CE, RCM Drop Protection: 6.6 ft (2m) Clamp/Jaw Opening: 0.75 in (19mm) AC Voltage: 1000V DC Voltage: 1000V AC Current: 200A DC Current: 200A Ohms: 60MΩ AC Millivolts: Yes DC Millivolts: Yes True RMS: Yes High Voltage Alarm: ACV/DCV | >30V Audible Continuity: Yes Visual Continuity: Yes Backlight: Yes NCV: 40-600V Auto Ranging: Yes Range Hold: Yes Data Hold: Yes Relative: Yes Diode Test: Yes Capacitance Test: 6.000mF Max / Min: Yes Magnetic Strap Mount: Yes (Strap Non Included) Test Probe Holder: Yes Flashlight: Yes Auto-Power Off (APO): Yes APO Disable: Yes Battery Type: 2 x 1.5V AAA (Included) Bottom LCD Display: Yes LCD Display Count: 6000 Warranty: 2-Year Included Accessories: Leads, Case & Batteries Document Spec Sheet Instruction Catalogue Test Lead Selection Chart Warranty
Description The Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display. Use the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces. Your job will get easier when you use the 377 FC clamp meter. The display turns green when a stable FieldSense measurement is detected. Visual Continuity also provides a bright green screen for easy detection of continuity in noisy work areas. With Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows you to gather data as the basis for a preventive maintenance program. Features Complete 3-phase voltage and current tests in 3 easy steps Full set of phase-to-ground and phase-to-phase values calculated and shown on the meter Values are also displayed on your smart phone and saved to the cloud via Fluke Connect software Phase rotation auto-calculated and shown on the Fluke Connect software No more hand-written notes or complicated math. Measure voltage and current with your clamp jaw Faster, safer testing - all without touching a live wire - using FieldSense™ technology Technical Information General specifications General Maximum Voltage between any Terminal and Earth Ground 1000 V Battery Type 2 AA IEC LR6 alkaline Life 200 hour Display Dual readout Automatic Power Off 20 minutes Electrical AC Current: Jaw Range 999.9 A Resolution 0.1 A Accuracy 2 % ±5 digits (45 Hz to 66 Hz) Crest Factor (50/60 Hz) 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2 % for C.F. >2 AC Current: Flexible Current Probe Range 2500 A Resolution 1 A (≤2500 A) 0.1 A (≤999.9 A) Accuracy 3 % ±5 digits (5 Hz to 500 Hz) Crest Factor (50/60Hz) 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2 % for C.F. >2 Position Sensitivity Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5 % B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0 % C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 999.9 A Resolution 0.1 A Accuracy 2 % ±5 digits 1 [1] When using the ZERO function to compensate for offsets AC Voltage: Field Sense Range 1000 V Resolution 1 V (≤1000V) Accuracy ≤4/0 AWG 3 % ±5 digits (45 Hz to 66 Hz) ≥4/0 AWG 5 % ±5 digits (45 Hz to 66 Hz) Position wire as close as possible to jaw opening (see illustration). AC Voltage: Test Leads Range 600.0 V 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1 % ±5 digits (20 Hz to 500 Hz) DC Voltage Range 600.0 V 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1 % ±5 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1 % ±5 digits Amps Frequency: Jaw Range 45 Hz to 66 Hz Resolution 0.1 Hz Accuracy 0.5 % ±5 digits Trigger Level 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥ 5 A 100 Hz to 500 Hz, ≥ 10 A Amps Frequency: Flexible Current Probe Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5 % ±5 digits Trigger Level 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz,≥25 A Resistance Range 60.00 kΩ 6000 Ω 600.0 Ω Resolution 0.1 Ω (≤600.0 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60.00 kΩ) Accuracy 1 % ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤100.0 μF) 1 μF (≤1000 μF) Accuracy 1 % ±4 digits Mechanical Size (L x W x H) 274 mm x 86 mm x 47 mm Weight (with Batteries) 463 g Jaw Opening 34 mm Flexible Current Probe Diameter 7.5 mm Flexible Current Probe Cable Length (head to electronics connector) 1.8 m Rogowski Coil Length 450 mm Environmental Operating Temperature -10 °C to 50 °C Storage Temperature -40 °C to 60 °C Operating Humidity (without condensation) Non condensing (28 °C or <18 °C Ingress Protection IEC 60529: IP30 (jaw closed) Operating Altitude 2000 m Storage Altitude 12 000 m Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2, CISPR 11: Group 1, Class B Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Safety General IEC 61010-1: Pollution degree 2 Measurement IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V Current Clamp for Leakage Current Measurements IEC 61557-13: Class 2, ≤30 A/m Wireless Radio Radio Frequency Certification FCC ID: T68-FBLE IC:6627A-FBLE Frequency Range 2405 MHz to 2480 MHz Output Power <100 mW Radio Frequency Data Radio Frequency Data For Class A Devices SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU. The full text of the EU declaration is available at the following internet address: https://dam-assets.fluke.com/s3fs-public/FLK_RED_1aeng0900.pdf . Document User's manual Quick Reference
Description The Fluke 374 FC, part of the Fluke Connect family of wireless test tools, delivers the standard features you need for everyday troubleshooting. Measure AC and DC current to 600 A with the fixed jaw clamp or add an optional iFlex® flexible current probe to measure all the way to 2500 A. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access tightly packed wires. You can also use the 374 FC to measure AC and DC voltage to 1000 V and resistance to 6000 Ω. The 374 FC is Fluke Connect-enabled to wirelessly transmit results via Bluetooth to Apple and Android devices. That means you can read the results out of the arc flash zone, wearing less PPE. You can even save results to the cloud and create and send reports in email right from the field. Or converse in real-time with ShareLive™ video calls. With True-RMS AC voltage and current measurements, the 374 FC enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 374 FC Clamp Meter is the direct replacement for the Fluke 374 Clamp Meter. What's in the box: 374 FC AC/DC Clamp Meter (1 pair) TL75 test leads Two AA Alkaline batteries (Installed) Soft carrying case Quick Reference Guide Features Advanced clamp meter that transmits measurements to your smartphone via Fluke Connect® for viewing at a safer distance Performs AC and DC current measurements to 600 A, and AC and DC voltage measurements to 1000 V Measures AC current to 2500 A AC with optional iFlex flexible current probe Measures resistance to 6000 Ω with continuity detection Compatible with optional TPAK magnetic hanging strap Comes with soft carrying case, batteries, and three-year warranty Measures capacitance to 1000 µF Features CAT III 1000 V, CAT IV 600 V safety rating Provides True-RMS voltage and current measurements to accurately measure non-linear signals Includes Min/Max/Avg and inrush recording to capture variations automatically Runs on two AA alkaline batteries Technical Information General Specifications AC Current via Jaw Range 600.0 A Resolution 0.1 A Accuracy 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100-500 Hz) Crest Factor (50 Hz/60 Hz) 2.5 @ 600 A Add 2% for C.F. >2 AC Current via Flexible Current Probe Range 2500 A Resolution 0.1 A (≤ 600 A) 1 A (≤ 2500 A) Accuracy 3% ±5 digits (5 – 500 Hz) Crest Factor (50/60Hz) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 Position Sensitivity Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5 % B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0 % C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 600.0 A Resolution 0.1 A Accuracy 2% ±5 digits AC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1.5% ±5 digits (20 Hz to 500 Hz) DC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1% ±5 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1% ±5 digits Resistance Range 6000 Ω Resolution 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) Accuracy 1% ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) Accuracy 1% ±4 digits Mechanical Specifications Maximum voltage between any terminal and earth ground 1000 V Batteries 2 AA, NEDA 15A, IEC LR6 Operating temperature -10 °C to +50 °C Storage temperature -40 °C to +60 °C Operating humidity - non-condensing (< 10°C) ≤90% RH (at 10 °C to 30 °C) ≤75% RH (at 30 °C to 40 °C) ≤45% RH (at 40 °C to 50 °C) Operating altitude 3000 m Storage altitude 12,000 m Size (L x W x H) 249 x 85 x 45 mm Weight 395 g Jaw opening 34 mm Flexible current probe diameter 7.5 mm Flexible current probe cable length (head to electronics connector) 1.8 m Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V IP rating IEC 60529: IP30, non-operating Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C Document User's Manual Datasheet Brochure
Description Now one technician can do jobs that would otherwise require two people. Clamp the Fluke 381 around a conductor, remove the display and walk across the room to operate controls or remove protective equipment, all while watching real-time readings. The iFlex® Flexible Current Probe (included) expands the measurement range to 2500 A AC while providing increased display flexibility. With a cord that runs 6 feet, you can finally measure those tight spaces, awkward sized conductors and disorganized wires. Features Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement with measurement accuracy Removable magnetic display can be mounted where it is easily seen iFlex® Flexible Current Probe expands the measurement range to 2500 A AC CAT IV 600 V, CAT III 1000 V Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it Ergonomic design fits in your hand and can be used while wearing protective equipment Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement Three-year warranty Technical Information Electrical Specifications AC Current via Jaw Range 999.9 A Resolution 0.1 A Accuracy 2% ± 5 digits (10-100 Hz) 5% ± 5 digits (100-500 Hz) Crest Factor (50/60 Hz) 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2% for C.F. > 2 AC Current via Flexible Current Probe Range 999.9 A / 2500 A (45 Hz – 500 Hz) Resolution 0.1 A / 1 A Accuracy 3% ± 5 digits Crest Factor (50/60 Hz) 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 Position Sensitivity Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5% B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0% C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0% Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 999.9 A Resolution 0.1 A Accuracy 2% ± 5 digits AC Voltage Range 600 V /1000 V Resolution 0.1 V / 1 V Accuracy 1.5% ± 5 digits (20 – 500 Hz) DC Voltage Range 600.0 V /1000 V Resolution 0.1 V / 1 V Accuracy 1% ± 5 digits Frequency – Via Jaw Range 5.0 – 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ± 5 digits Trigger Level 5 – 10 Hz, ≥ 10 A 10 – 100 Hz, ≥ 5 A 100 – 500 Hz, ≥ 10 A Frequency via Flexible Current Probe Range 5.0 to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ± 5 digits Trigger Level 5 to 20 Hz, ≥ 25 A 20 to 100 Hz, ≥ 20 A 100 to 500 Hz, ≥ 25 A Resistance Range 600 Ω/6 kΩ/60 kΩ Resolution 0.1 Ω/1 Ω/10 Ω Accuracy 1% ± 5 digits Mechanical Specifications Size (L x W x H) 277 x 88 x 43 mm (55 mm for remote unit) Weight 350 g Jaw Opening 34 mm Flexible Current Probe Diameter 7.5 mm Flexible Current Probe Cable Length (head to electronics connector) 1.8 m Environmental Specifications Operating Temperature -10°C to +50°C Storage Temperature -40°C to +60°C Operating Humidity Non condensing (< 10°C) ≤ 90% RH (at 10°C to 30°C) ≤ 75% RH (at 30°C to 40°C) ≤ 45% RH (at 40°C to 50°C) (Without Condensation) Operating Altitude 2,000 meters Storage Altitude 12,000 meters EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID: T68-F381 RSS-210 IC: 6627A-F381 Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C Wireless Frequency 2.4 GHz ISM Band 10 meter range Safety Compliance ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV. Double Insulation Clearance Per IEC 61010-2-032 Double Insulation Creepage Per IEC 61010-1 Agency Approvals Document User's Manual Quick Reference
Description “The Fluke 1630 is a MUST HAVE for those who are intent on improving the reliability of their systems and making it impervious to impulse damage. The Fluke 1630 is easy to use, highly accurate and an industry standard”- verified purchaser The 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes. Features Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. AC Leakage Current Measurement: Identify AC leakage without disconnecting your earth ground stake from the grounding system Rugged: Heavy-duty clamp jaw stays in alignment and calibration on tough jobsites Logging measurement: Saves up to 32,760 measurements in memory Technical Information Electrical Specifications Maximum voltage to earth ground 1000 V Battery type AA alkaline IEC/EN LR6 (x4) Battery life More than 15 hours* * In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off Frequency range 40 Hz to 1 kHz Ingress protection IEC/EN 60529: IP30 with jaw closed LCD Digital reading 9999 counts Refresh rate 4 per second Operating temperature -10 °C to + 50 °C Storage temperature -20 °C to + 60 °C Operating humidity Non condensing (28 °C [82.4 °F]) Overload indication OL Data logging capacity Minimum of 32,760 measurements Data logging interval 1 second to 59 minutes and 59 seconds Display reading specification with standard loop resistance Input (Ω) Minimum Maximum 0.474 0.417 0.531 0.5 0.443 0.558 10 9.55 10.45 100 96 104 Safety General IEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1 Measurement IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V Current clamp for leakage current measurements IEC/EN 61557-13: Class 2, ≤30 A/m Resistance to earth IEC/EN 61557-5 Effectiveness of thepProtective measures IEC/EN 61557-16 Electromagnetic compatibility (EMC) International IEC/EN 61326-1: Portable Electromagnetic Environment CISPR 11: Group 1, Class B, IEC/EN 61326-2-2 Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment) USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 Wireless Radio Frequency range 2412 MHz to 2462 MHz Output power <10 mW Radio frequency certification FCC ID:T68-FBLE IC:6627A-FBLE General Specifications Conductor size 40 mm (1.57 in) approximately Dimensions (L x W x H) 283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in) Weight 880g (31 oz) Warranty One year Earth Ground Loop Resistance Range Accuracy 1 ± (% of reading + Ω) 0.025 Ω to 0.249 Ω 1.5% + 0.02 Ω 0.250 Ω to 0.999 Ω 1.5% + 0.05 Ω 1.000 Ω to 9.999 Ω 1.5% + 0.10 Ω 10.00 Ω to 49.99 Ω 1.5% + 0.30 Ω 50.00 Ω to 99.99 Ω 1.5% + 0.50 Ω 100.0 Ω to 199.9 Ω 3.0% + 1.0 Ω 200.0 Ω to 399.9 Ω 5.0% + 5.0 Ω 400 Ω to 599 Ω 10.0% + 10 Ω 600 Ω to 1500 Ω 20.00% 1 Loop resistance with no inductance, conductor centered and perpendicular to jaw Earth ground leakage current mA Autorange 50/60 Hz, True rms, crest factor CF ≤3 Range Resolution Accuracy 1 ± (% of reading + mA) 0.200 mA to 3.999 mA 1 μA 2.0% + 0.05 mA 4.00 mA to 39.99 mA 10 μA 2.0% + 0.03 mA 40.0 mA to 399.9 mA 100 μA 2.0% + 0.3 mA 0.400 A to 3.999 A 1 mA 2.0% + 3 mA 4.00 A to 39.99 A 10 mA 2.0% + 30 mA 1 Applies to signal frequency 40 Hz to 1 kHz with filter set to OFF 40 Hz to 70 Hz with filter se to ON Document User's Manual Quick Reference Brochure
Description The Fluke 771 delivers all the basic functionality you would expect in a milliamp clamp meter. It measures 4-20 mA signals without "breaking the loop," allowing you to measure low level DC current without having to take systems offline for troubleshooting, saving downtime and money. You can also use it to measure output signals from transmitters without breaking the loop when maintaining and troubleshooting process and automation equipment. This saves time and avoids disrupting critical processes so you can avoid expensive downtime. You can also measure 10 to 50 mA signals in older control systems using the 99.9 mA range. Designed to make troubleshooting easier, the Fluke 771 includes a detachable clamp that can be attached to the wire you're testing while you move the meter—connected by the extension cable—to a better viewing position. This is especially helpful for taking readings in tight locations. With the dual backlit display showing both the mA measurement and the percent of a 4 to 20 mA span you can quickly understand what your system is doing, and a built-in LED spotlight lets you illuminate hard to see wire in dark enclosures. You can also capture and display changing measurements using the Hold function making it easier to verify and record measurements. Features Measures 4 to 20 mA signals without breaking the loop Best in class 0.2% accuracy Delivers 0.01 mA resolution and sensitivity Measures mA signals for PLC and control system analog I/O Detachable clamp for measurements in tight locations Technical Information Specifications Diameter of measurable conductor 0.177 in or 4.5 mm max Operating temperature -10 to 50°C Storage temperature -25 to 60°C Operating humidity 28°C) Power, battery life (2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical Warranty Three years for electronics One year for cable and clamp assembly Functional Specifications mA measurement (measured by clamp) Resolution / range 0 to 20.99 mA Accuracy 0.2% + 2 counts Resolution / range 21.0mA to 100.0 mA Accuracy 1% + 5 counts Document Datasheet
Description The Fluke 375 FC, part of the Fluke Connect family of wireless test tools, delivers high performance features and ease of use. It features a VFD low-pass filter for accurate motor drive measurements and wireless communications to transmit results to a smartphone via Fluke Connect The 375 FC offers most of the features of the Fluke 376 FC including compatibility with the iFlex flexible current probe but, unlike the 376 FC, it does not include the iFlex® probe in the package. You can measure AC and DC current to 600 A and voltage up to 1000 V with the fixed jaw clamp. Or connect an optional iFlex® flexible current probe to expand your measurement range to 2500 A AC. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access individual wires. Using its Bluetooth connectivity to Apple and Android devices, you can read the 375 FC results a safe distance away on your smartphone, wearing less PPE. You can create and send reports in email right from the field and save results to the cloud. You can also converse with colleagues in real-time with ShareLive™ video calls. With True-RMS AC voltage and current measurements, the 375 enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 375 FC Clamp Meter is the direct replacement for the Fluke 375 Clamp Meter. Features High performance clamp meter that measures very low voltage and high resistance Transmits measurements to your smartphone via Fluke Connect® so you can view them at a safer distance Measures AC and DC current to 600 A, and AC and DC voltage to 1000 V Measures AC current to 2500 A AC with optional iFlex flexible current probe Compatible with optional TPAK magnetic hanging strap Comes with batteries, soft carrying case, and three-year warranty Features CAT III 1000 V, CAT IV 600 V safety rating Measures capacitance to 1000 µF Includes True-RMS voltage and current measurements to accurately measure non-linear signals Measures frequency to 500 Hz and resistance to 60 kΩ with continuity detection Includes Min/Max/Avg and inrush recording to capture variations automatically Offers 500 mV DC measurement range to interface with other accessories Runs on two AA alkaline batteries Technical Information General Specifications AC Current via Jaw Range 600.0 A Resolution 0.1 A Accuracy 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100-500 Hz) Crest Factor (50 Hz/60 Hz) 3 @ 500 A 2.5 @ 600 A Add 2% for C.F. >2 AC Current via Flexible Current Probe Range 2500 A Resolution 0.1 A (≤ 600 A) 1 A (≤ 2500 A) Accuracy 3% ±5 digits (5 – 500 Hz) Crest Factor (50/60Hz) 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 Position Sensitivity i2500-10 Flex i2500-18 Flex A Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm) Error ±0.5 % ±0.5 % B Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm) Error ±1.0 % ±1.0 % C Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm) Error ±2.0 % ±2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 600.0 A Resolution 0.1 A Accuracy 2% ±5 digits AC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1.5% ±5 digits (20 Hz to 500 Hz) DC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1% ±5 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1% ±5 digits Frequency via Jaw Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ±5 digits Trigger level 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥5 A Frequency via Flexible Current Probe Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ±5 digits Trigger level 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A Resistance Range 60 kΩ Resolution 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60 kΩ) Accuracy 1% ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) Accuracy 1% ±4 digits Mechanical Specifications Maximum voltage between any terminal and earth ground 1000 V Batteries 2 AA, NEDA 15A, IEC LR6 Operating temperature -10 °C to +50 °C Storage temperature -40 °C to +60 °C Operating humidity - non-condensing (< 10°C) ≤90% RH (at 10 °C to 30 °C) ≤75% RH (at 30 °C to 40 °C) Operating altitude 3000 m Storage altitude 12,000 m Size (L x W x H) 249 x 85 x 45 mm Weight 395 g Jaw opening 34 mm Flexible current probe diameter 7.5 mm Flexible current probe cable length (head to electronics connector) 1.8 m Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IP rating IEC 60529: IP30, non-operating Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C Document User's Manual Datasheet Brochure
Description The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity. Find the cause of difficult problems The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it. Measure: Voltage to 1000 V AC or DC Resistance to 60 kΩ with continuity detection Min, max, average, and inrush recording to capture variations automatically 500 mV DC measurement range to interface with other accessories 1000 μF capacitance measurement Work safely and conveniently The 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool. The included 18-inch or 36-inch iFlex flexible current probe provides easier access to large conductors in tight spaces. The flexible probe: Expands the measurement range to 2500 A AC Allows frequency measurement to 500 Hz with body jaw and iFlex Features Measures AC/DC current with included 18-inch or 36-inch iFlex current probe VFD low pass filter for accurate measurements of non-linear signals Remotely log, trend and monitor to pinpoint intermittent faults Inrush measurement to filter out noise and capture starting current Technical Information General Specifications AC Current via Jaw Range 999.9 A Resolution 0.1 A Accuracy 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100-500 Hz) Crest Factor (50 Hz/60 Hz) 3 @ 500 A 2.5 @ 600 A Add 2% for C.F. >2 AC Current via Flexible Current Probe Range 2500 A Resolution 0.1 A (≤ 600 A) 1 A (≤ 2500 A) Accuracy 3% ±5 digits (5 – 500 Hz) Crest Factor (50/60Hz) 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 i2500-10 Flex i2500-18 Flex i2500-36 Flex A Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm) 4.8 in (122.2 mm) Error ±0.5 % ±0.5 % ±0.5 % B Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm) 5.3 in (133.6 mm) Error ±1.0 % ±1.0 % ±1.0 % C Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm) 5.8 in (147.6 mm) Error ±2.0 % ±2.0 % ±2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 999.9 A Resolution 0.1 A Accuracy 2% ±5 digits AC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1% ±5 digits (20 Hz to 500 Hz) DC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1% ±5 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1% ±5 digits Frequency via Jaw Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ±5 digits Trigger level 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥5 A 100 Hz to 500 Hz, ≥10 A Frequency via Flexible Current Probe Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ±5 digits Trigger level 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A Resistance Range 60 kΩ Resolution 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60 kΩ) Accuracy 1% ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) Accuracy 1% ±4 digits Mechanical Specifications Maximum voltage between any terminal and earth ground 1000 V Batteries 2 AA, NEDA 15A, IEC LR6 Operating temperature -10 °C to +50 °C Storage temperature -40 °C to +60 °C Operating humidity - non-condensing (< 10°C) ≤90% RH (at 10 °C to 30 °C) ≤75% RH (at 30 °C to 40 °C) ≤45% RH (at 40 °C to 50 °C) Operating altitude 2000 m Storage altitude 12,000 m Size (L x W x H) 249 x 85 x 45 mm Weight 395 g Jaw opening 34 mm Flexible current probe diameter 7.5 mm Flexible current probe cable length (head to electronics connector) 1.8 m Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V IP rating IEC 60529: IP30, non-operating Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C Document User's Manual Datasheet Brochure
Description Includes IDEAL 61-744 Clamp Meter features a compact jaw design for reaching into tight spaces. Convenient low battery indicator and auto power off so that you can ensure your clamp meter is always charged and ready to use. To extend the life of your battery, the meter shuts of after approximately 10 minutes of non-use. IDEAL Electrical has been committed to craft and its craftsmen for more than 100 years. Whether you’re the electrical contractor or datacomm technician, production engineer or plant manager, we know the job the way you know the job. Features Measures up to 600A AC Non-contact voltage indicator (70V-600VAC) Continuity Tapered jaws with hook tip Auto/manual ranging Data hold Auto power off Low battery indicator Document Instruction
Description Use the Greenlee CSJ-100 Open-Jaw Clamp Meter anytime you need to measure amperage or voltage. It's easy to use with its slim, compact profile and bright LED. It offers a data hold function to capture the readings, and comes with test leads and a carrying case. Benefits AC amperage, AC/DC voltage measurement Open jaw design eases AC current measurement Slim profile with build-in probe storage on back Measures resistance up to 20MΩ Audible continuity and diode test Bright LED and audible alarm for non-contact voltage detection Auto power off for longer battery life Data hold to capture measurements 2000 count LCD Accessories included: (2)1.5V AAA batteries, test leads and carrying case Technical Information Brand: Greenlee Amperage: 200 Voltage Measurement: 200, 1000V Resistance Measurement: 200 Ω; 2, 20, 200 kΩ; 2, 20 MΩ Display: LCD, 4000 Count Jaw Opening: 1.02" (26 mm) Measurement Category: CAT III, 600 V Per UL 61010-1 Standard: CAT IV, C/US UL Listed, CAT III, CE Listed Documents Instruction Manual
Description Whether you need to measure amperage or voltage, this Greenlee CM-450 Digital Clamp-On Meter has you covered. It measures up to 600 A and 600 VAC/VDC with true RMS for accuracy. The LCD makes it easy to see the readings, and the data hold function can be used to capture the screen in place. Benefits AC amperage, AC/DC voltage measurement True RMS for the most accurate measurement where harmonics are present Quick, easy operation Auto power off for longer battery life Resistance measurement Audible continuity and diode tests Frequency measurement Data hold to capture measurement 4000 count LCD Accessories included: Test leads, 3V Standard button battery (IEC-CR 2032; ANSI-NEDA 54004LC) Technical Information Brand: Greenlee Amperage Measurement: 40, 400, 600 A AC Jaw Opening: 1.02" (26 mm) Display: LCD, 4000 count Voltage AC: 4, 40, 400, 600 V AC Voltage DC: 400 mV, 4, 40, 400, 600V DC Resistance: 400Ω; 4, 40, 400Ω; 4, 40MΩ Measurement Category: CAT III, 600V per UL 61010-1 Documents Instruction Manual
Description Use this Greenlee CM-330 Clamp-On Ammeter to easily measure AC currents. It's capable of reading up to 400 A and displays the information on the 2,000-count LCD. Thanks to its compact size, you can stow the meter inside any tool pouch whenever you're not using it. Benefits AC current measuring capability up to 400 amps Compact size, fits easily into tool pouch Data hold and Max hold to capture important readings 2000-Count LCD Lifetime Limited Warranty Accessories included: (1) 9V battery, carrying case Lifetime Limited Warranty Technical Information Brand: Greenlee Weight: 1 lb. (45 g) Amperage measurement 20.00, 200.0, 400 A AC Jaw Opening 1.18" (30 mm) Display 2000-count LCD Measurement Category CAT III, 600 V per UL 61010B-1 Documents Instruction Manual