Skip to content

Roof & Pipe Heating

  • $337.99

    nVent Raychem Frostguard Freeze Protection Plug-In Kit 50 FT, FG150P

    nVent Raychem
    Description nVent Raychem FrostGuard pre-assembled self-regulating heating cables are designed for freeze protection of pipes and roof and gutter de-icing applications. Available as 120V, in various lengths with a 6 ft power cord. Benefits Simple to design: 120 V version in 6, 12, 18, 24, 36, 50, 75 and 100 ft lengths each with a 6 ft power cord and 3-prong, grounded, lighted plug to show the system is on. Easy to install: pre-assembled with a plug and cold lead to avoid the need for connection by an electrician Energy efficient and safe: self-regulating cable, no overheating possible even when overlapped or closely spaced Reliable during long life: 2 year product warranty available, maintenance free. Technical Information Brand: NVent RAYCHEM Lenght: 50 FT Heating Cable Technology: Self-Regulating Nominal Voltage: 120V Color: Black Ground Path Type: Braid Min Installation Temperature: -15 °C Nominal Width: 11.4 mm Nominal Height: 6.1 mm Max Continuous Exposure Temperature, Power On: 65 °C Cold Lead Length: 1.83 m Documents Installation Manual Datasheet
    • Temporarily out of stock
    • Notify me when back in stock
  • $192.70

    nVent Raychem Frostguard Freeze Protection Plug-In Kit 24 FT, Model FG124P

    nVent Raychem
    Description nVent Raychem FrostGuard pre-assembled self-regulating heating cables are designed for freeze protection of pipes and roof and gutter de-icing applications. Available as 120V, in various lengths with a 6 ft power cord. Benefits Simple to design: 120 V version in 6, 12, 18, 24, 36, 50, 75 and 100 ft lengths each with a 6 ft power cord and 3-prong, grounded, lighted plug to show the system is on. Easy to install: pre-assembled with a plug and cold lead to avoid the need for connection by an electrician Energy efficient and safe: self-regulating cable, no overheating possible even when overlapped or closely spaced Reliable during long life: 2 year product warranty available, maintenance free. Technical Information Brand: NVent RAYCHEM Lenght: 24 FT Heating Cable Technology: Self-Regulating Nominal Voltage: 120V Color: Black Ground Path Type: Braid Min Installation Temperature: -15 °C Nominal Width: 11.4 mm Nominal Height: 6.1 mm Max Continuous Exposure Temperature, Power On: 65 °C Cold Lead Length: 1.83 m Documents Installation Manual Datasheet
    • In stock
    • Free shipping
  • $161.26

    nVent Raychem Frostguard Freeze Protection Plug-In Kit 18 FT, Model FG118P

    nVent Raychem
    Description nVent Raychem FrostGuard pre-assembled self-regulating heating cables are designed for freeze protection of pipes and roof and gutter de-icing applications. Available as 120V, in various lengths with a 6 ft power cord. Benefits Simple to design: 120 V version in 6, 12, 18, 24, 36, 50, 75 and 100 ft lengths each with a 6 ft power cord and 3-prong, grounded, lighted plug to show the system is on. Easy to install: pre-assembled with a plug and cold lead to avoid the need for connection by an electrician Energy efficient and safe: self-regulating cable, no overheating possible even when overlapped or closely spaced Reliable during long life: 2 year product warranty available, maintenance free. Technical Information Brand: NVent RAYCHEM Lenght: 18 FT Heating Cable Technology: Self-Regulating Nominal Voltage: 120V Color: Black Ground Path Type: Braid Min Installation Temperature: -15 °C Nominal Width: 11.4 mm Nominal Height: 6.1 mm Max Continuous Exposure Temperature, Power On: 65 °C Cold Lead Length: 1.83 m Documents Installation Manual Datasheet
    • Temporarily out of stock
    • Notify me when back in stock
  • $263.11

    nVent Raychem Frostguard Freeze Protection Plug-In Kit 36 FT, Model FG136P

    nVent Raychem
    Description nVent Raychem FrostGuard pre-assembled self-regulating heating cables are designed for freeze protection of pipes and roof and gutter de-icing applications. Available as 120V, in various lengths with a 6 ft power cord. Benefits Simple to design: 120 V version in 6, 12, 18, 24, 36, 50, 75 and 100 ft lengths each with a 6 ft power cord and 3-prong, grounded, lighted plug to show the system is on. Easy to install: pre-assembled with a plug and cold lead to avoid the need for connection by an electrician Energy efficient and safe: self-regulating cable, no overheating possible even when overlapped or closely spaced Reliable during long life: 2 year product warranty available, maintenance free. Technical Information Brand: NVent RAYCHEM Lenght: 36 FT Heating Cable Technology: Self-Regulating Nominal Voltage: 120V Color: Black Ground Path Type: Braid Min Installation Temperature: -15 °C Nominal Width: 11.4 mm Nominal Height: 6.1 mm Max Continuous Exposure Temperature, Power On: 65 °C Cold Lead Length: 1.83 m Documents Installation Manual Datasheet
    • Temporarily out of stock
    • Notify me when back in stock
  • $609.94

    nVent Raychem Frostguard Freeze Protection Plug-In Kit 100 FT, Model FG1100P

    nVent Raychem
    Description nVent Raychem FrostGuard pre-assembled self-regulating heating cables are designed for freeze protection of pipes and roof and gutter de-icing applications. Available as 120V, in various lengths with a 6 ft power cord. Benefits Simple to design: 120 V version in 6, 12, 18, 24, 36, 50, 75 and 100 ft lengths each with a 6 ft power cord and 3-prong, grounded, lighted plug to show the system is on. Easy to install: pre-assembled with a plug and cold lead to avoid the need for connection by an electrician Energy efficient and safe: self-regulating cable, no overheating possible even when overlapped or closely spaced Reliable during long life: 2 year product warranty available, maintenance free. Technical Information Brand: NVent RAYCHEM Lenght: 100 FT Heating Cable Technology: Self-Regulating Nominal Voltage: 120V Color: Black Ground Path Type: Braid Min Installation Temperature: -15 °C Nominal Width: 11.4 mm Nominal Height: 6.1 mm Max Continuous Exposure Temperature, Power On: 65 °C Cold Lead Length: 1.83 m Documents Installation Manual Datasheet
    • Temporarily out of stock
    • Notify me when back in stock
  • $101.41

    nVent Raychem Frostguard Freeze Protection Plug-In Kit 6 FT, Model FG16P*

    nVent Raychem
    Description nVent Raychem FrostGuard pre-assembled self-regulating heating cables are designed for freeze protection of pipes and roof and gutter de-icing applications. Available as 120V, in various lengths with a 6 ft power cord. Benefits Simple to design: 120 V version in 6, 12, 18, 24, 36, 50, 75 and 100 ft lengths each with a 6 ft power cord and 3-prong, grounded, lighted plug to show the system is on. Easy to install: pre-assembled with a plug and cold lead to avoid the need for connection by an electrician Energy efficient and safe: self-regulating cable, no overheating possible even when overlapped or closely spaced Reliable during long life: 2 year product warranty available, maintenance free. Technical Information Brand: NVent RAYCHEM Lenght: 6 FT Heating Cable Technology: Self-Regulating Nominal Voltage: 120V Color: Black Ground Path Type: Braid Min Installation Temperature: -15 °C Nominal Width: 11.4 mm Nominal Height: 6.1 mm Max Continuous Exposure Temperature, Power On: 65 °C Cold Lead Length: 1.83 m Documents Installation Manual Datasheet
    • Available for special order
  • $474.05

    nVent Raychem Frostguard Freeze Protection Plug-In Kit 75 FT, Model FG175P

    nVent Raychem
    Description nVent Raychem FrostGuard pre-assembled self-regulating heating cables are designed for freeze protection of pipes and roof and gutter de-icing applications. Available as 120V, in various lengths with a 6 ft power cord. Benefits Simple to design: 120 V version in 6, 12, 18, 24, 36, 50, 75 and 100 ft lengths each with a 6 ft power cord and 3-prong, grounded, lighted plug to show the system is on. Easy to install: pre-assembled with a plug and cold lead to avoid the need for connection by an electrician Energy efficient and safe: self-regulating cable, no overheating possible even when overlapped or closely spaced Reliable during long life: 2 year product warranty available, maintenance free. Technical Information Brand: NVent RAYCHEM Lenght: 75 FT Heating Cable Technology: Self-Regulating Nominal Voltage: 120V Color: Black Ground Path Type: Braid Min Installation Temperature: -15 °C Nominal Width: 11.4 mm Nominal Height: 6.1 mm Max Continuous Exposure Temperature, Power On: 65 °C Cold Lead Length: 1.83 m Documents Installation Manual Datasheet
    • In stock
    • Free shipping
  • $128.44

    nVent Raychem Frostguard Freeze Protection Plug-In Kit 12 FT, Model FG112P

    nVent Raychem
    Description nVent Raychem FrostGuard pre-assembled self-regulating heating cables are designed for freeze protection of pipes and roof and gutter de-icing applications. Available as 120V, in various lengths with a 6 ft power cord. Benefits Simple to design: 120 V version in 6, 12, 18, 24, 36, 50, 75 and 100 ft lengths each with a 6 ft power cord and 3-prong, grounded, lighted plug to show the system is on. Easy to install: pre-assembled with a plug and cold lead to avoid the need for connection by an electrician Energy efficient and safe: self-regulating cable, no overheating possible even when overlapped or closely spaced Reliable during long life: 2 year product warranty available, maintenance free. Technical Information Brand: NVent RAYCHEM Lenght: 12 FT Heating Cable Technology: Self-Regulating Nominal Voltage: 120V Color: Black Ground Path Type: Braid Min Installation Temperature: -15 °C Nominal Width: 11.4 mm Nominal Height: 6.1 mm Max Continuous Exposure Temperature, Power On: 65 °C Cold Lead Length: 1.83 m Documents Installation Manual Datasheet
    • Temporarily out of stock
    • Notify me when back in stock
  • $28.59

    nVent Raychem WinterGard Hanger Bracket Kit Downspout, Model H915

    nVent Raychem
    Description The nVent RAYCHEM WinterGard H915 Hanger Bracket Kit provides mechanical protection and strain relief for WinterGard Wet heating cables when entering downspouts and over sharp edges. Benefits Hanger Bracket kit for WinterGard Wet heating cables Mechanical protection and strain relif for WinterGard Wet cables for downspouts and sharp edges UL and CSA listed Technical Information Brand: nVent Raychem Material: Aluminum Height: 298.5 mm Width: 25.4 mm Depth: 1.5 mm Documents Spec Sheet Installation Instructions
    • Low stock
    • Eligible for free shipping
  • Original price$104.80
    Current price$73.36

    nVent Raychem WinterGard Roof Clips (Pack of 50), Model H914

    nVent Raychem
    Description The nVent RAYCHEM WinterGard H913 and H914 are roof clip bracket kits that are used to secure WinterGard Wet heating cables to roofs and gutters. The clips may be attached with mechanical fasteners (screws or nails) on shake roofs or using adhesive on metal, slate or composite roofing. The H913 and H914 kits are approved for use with UL Listed and CSA Certified WinterGard Wet heating cable systems or FrostGuard pre-terminated heating cables. The H914 includes 50 roof clips. Benefits Simple to install Maintenance free Reliable during long life: 2 year product warranty available Technical Information Brand: n Vent R aychem Clips: 50 per bag Material: Anodized Aluminum Height: 19.3 mm Width: 38 mm Length: 53.3 mm Documents Spec Sheet Installation Instructions
    • Low stock
    • Eligible for free shipping
  • Original price$31.16
    Current price$15.58

    nVent Raychem WinterGard Roof Clips (Pack of 10), Model H913

    nVent Raychem
    Description The nVent RAYCHEM WinterGard H913 and H914 are roof clip bracket kits that are used to secure WinterGard Wet heating cables to roofs and gutters. The clips may be attached with mechanical fasteners (screws or nails) on shake roofs or using adhesive on metal, slate or composite roofing. The H913 and H914 kits are approved for use with UL Listed and CSA Certified WinterGard Wet heating cable systems or FrostGuard pre-terminated heating cables. The H913 includes 10 roof clips. Benefits Simple to install Maintenance free Reliable during long life: 2 year product warranty available Technical Information Brand: n Vent R aychem Clips: 10 per bag Material: Anodized Aluminum Height: 19.3 mm Width: 38 mm Length: 53.3 mm Documents Spec Sheet Installation Instructions
    • In stock
    • Eligible for free shipping
  • Original price$26.05
    Current price$13.03

    nVent Raychem WinterGard Warning Label & Tape, Model H903

    nVent Raychem
    Description The nVent Raychem WinterGard H903 Application Tape and Electric Traced Labels Kit enables application of nVent RAYCHEM electric heat tracing cable to pipes for residential and light commercial pipe freeze protection applications. Each kit includes one ½" wide, 66-foot (20-meter) roll of fiberglass-reinforced adhesive tape and ten “Electric Traced” safety labels. Labels should be affixed to thermal pipe insulation every 10 feet (3 m), alternating on either side of the pipe where required. Benefits Enables easy installation of nVent RAYCHEM heat tracing cable for pipe freeze protection Not for use with stainless steel pipes Technical Information Brand: NVent RAYCHEM Package Type Poly bag Package Size (LxWxD) 10" x 6" x 2" Package Weight 0.3 lb Documents Spec Sheet
    • Low stock
    • Eligible for free shipping
  • $122.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 700W 120V 140 ft. Model BGDC1-1A140*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 140 FT Watts: 700 W Amp: 5.8 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $93.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 500W 120V 100 ft. Model BGDC1-1A100*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 100 FT Watts: 500 W Amp: 4.2 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $78.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 280W 120V 40 ft. Model BFPC1-1A040*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 40 FT Watts: 280 W Amp: 2.34 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $42.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 126W 120V 18 ft. Model BFPC1-1A018*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 18 FT Watts: 126 W Amp: 1.05 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $124.99

    Global Commander Roof and Gutter Sentry for Automatic De-Icong Control with Humidity Probe, Model RCR-U*

    Global Commander
    Description Global Commander's roof heating cable control is intended to be used with their roof and gutter de-icing cable. It only energizes your roof and gutter de-icing cable when necessary by sensing temperature and moisture. it prevents excess electrical waste while helping to protect your roof from ice dams. When the weather is warm, the meltwater will continue to drain to the ground, so there is no reason for the roof heating cable to be energized. Also, when the ambient temperature is cold enough that the heat dissipated from the roof does not melt snow, there is no need for the roof heating cable to be energized. De-icing cables only need to operate when there is a possibility of meltwater refreezing and causing ice dams. Document Brochure Instruction
    • Available for special order
  • $66.99

    Global Commander 30 Feet 120V Preassembled Heating Cables for Roof and Gutter De-Icing, 5W/FT, Model ORF-R030*

    Global Commander
    Description Global Commander's preassembled heating cables for roof and gutter de-icing. Comes with a 3-pronged plug and roof clips for cable and spacers. Easy and quick to install. Available in multiple length. Features 120V Preassembled Cable 5 Watts per foot For outdoor applications only Roof clips for cable and spacers included Grounded 3-pronged plug with indicator light to show when the cable is powered on Technical Information Voltage: 120v Linear Density: 5w per Ft Cold Lead Length: 30 in (0.76m) Cable length: 30 FT (9.1m) Watts: 150w Outer Jacket: PVC Bus Wire: Nickel Plated Copper Minimum Bend Radius: 1/2 in (12mm) Warranty: 1-yar basic warranty on heating cable Application: Roof and Gutter De-Icing Document Brochure Instruction
    • Available for special order
  • $95.99

    Global Commander 100 Feet 120V Preassembled Heating Cables for Roof and Gutter De-Icing, 5W/FT, Model ORF-R100*

    Global Commander
    Description Global Commander's preassembled heating cables for roof and gutter de-icing. Comes with a 3-pronged plug and roof clips for cable and spacers. Easy and quick to install. Available in multiple length. Features 120V Preassembled Cable 5 Watts per foot For outdoor applications only Roof clips for cable and spacers included Grounded 3-pronged plug with indicator light to show when the cable is powered on Technical Information Voltage: 120v Linear Density: 5w per Ft Cold Lead Length: 30 in (0.76m) Cable length: 100 FT (30.5m) Watts: 500w Outer Jacket: PVC Bus Wire: Nickel Plated Copper Minimum Bend Radius: 1/2 in (12mm) Warranty: 1-yar basic warranty on heating cable Application: Roof and Gutter De-Icing Document Brochure Instruction
    • Available for special order
  • $73.99

    Global Commander 60 Feet 120V Preassembled Heating Cables for Roof and Gutter De-Icing, 5W/FT, Model ORF-R060*

    Global Commander
    Description Global Commander's preassembled heating cables for roof and gutter de-icing. Comes with a 3-pronged plug and roof clips for cable and spacers. Easy and quick to install. Available in multiple length. Features 120V Preassembled Cable 5 Watts per foot For outdoor applications only Roof clips for cable and spacers included Grounded 3-pronged plug with indicator light to show when the cable is powered on Technical Information Voltage: 120v Linear Density: 5w per Ft Cold Lead Length: 30 in (0.76m) Cable length: 60 FT (18.3m) Watts: 300w Outer Jacket: PVC Bus Wire: Nickel Plated Copper Minimum Bend Radius: 1/2 in (12mm) Warranty: 1-yar basic warranty on heating cable Application: Roof and Gutter De-Icing Document Brochure Instruction
    • Available for special order
  • $42.99

    Global Commander 18 Feet 120V Preassembled Heating Cables for Pipes, 7W/FT, Model ORF-P018*

    Global Commander
    Description Global Commander's preassembled p ipe tracing for freeze protection. Available in multiple length. Features • 7 Watts per foot. • For indoor and outdoor applications. • Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). • For metallic and non-metallic pipes. • Grounded 3-pronged plug with indicator light to show when the cable is powered on. Technical Information Voltage: 120v Linear Density: 7w per Ft Cold Lead Length: 30 in (0.76m) Cable length: 18 FT (5.5m) Watts: 126w Outer Jacket: PVC Bus Wire: Nickel Plated Copper Minimum Bend Radius: 5/16 in (8mm) Warranty: 1-year basic warranty on heating cable Application: Metal and Non-Metallic Pipes. Helps to prevent damage caused by frozen pipes. Document Brochure Instruction
    • Available for special order
  • $30.99

    Global Commander 6 Feet 120V Preassembled Heating Cables for Pipes, 7W/FT, Model ORF-P006*

    Global Commander
    Description Global Commander's preassembled p ipe tracing for freeze protection. Available in multiple length. Features • 7 Watts per foot. • For indoor and outdoor applications. • Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). • For metallic and non-metallic pipes. • Grounded 3-pronged plug with indicator light to show when the cable is powered on. Technical Information Voltage: 120v Linear Density: 7w per Ft Cold Lead Length: 30 in (0.76m) Cable length: 6 FT (1.8m) Watts: 42w Outer Jacket: PVC Bus Wire: Nickel Plated Copper Minimum Bend Radius: 5/16 in (8mm) Warranty: 1-year basic warranty on heating cable Application: Metal and Non-Metallic Pipes. Helps to prevent damage caused by frozen pipes. Document Brochure Instruction
    • Available for special order
  • $57.99

    Global Commander 30 Feet 120V Preassembled Heating Cables for Pipes, 7W/FT, Model ORF-P030*

    Global Commander
    Description Global Commander's preassembled p ipe tracing for freeze protection. Available in multiple length. Features • 7 Watts per foot. • For indoor and outdoor applications. • Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). • For metallic and non-metallic pipes. • Grounded 3-pronged plug with indicator light to show when the cable is powered on. Technical Information Voltage: 120v Linear Density: 7w per Ft Cold Lead Length: 30 in (0.76m) Cable length: 30 FT (9.1m) Watts: 210w Outer Jacket: PVC Bus Wire: Nickel Plated Copper Minimum Bend Radius: 5/16 in (8mm) Warranty: 1-year basic warranty on heating cable Application: Metal and Non-Metallic Pipes. Helps to prevent damage caused by frozen pipes. Document Brochure Instruction
    • Available for special order
  • $172.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 1200W 120V 240 ft. Model BGDC1-1A240*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 240 FT Watts: 1200 W Amp: 10.0 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $160.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 1000W 120V 200 ft. Model BGDC1-1A200*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 200 FT Watts: 1000 W Amp: 8.3 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $153.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 900W 120V 180 ft. Model BGDC1-1A180*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 180 FT Watts: 900 W Amp: 7.5 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $133.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 800W 120V 160 ft. Model BGDC1-1A160*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 160 FT Watts: 800 W Amp: 6.7 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $109.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 600W 120V 120 ft. Model BGDC1-1A120*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 120 FT Watts: 600 W Amp: 5.0 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $87.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 400W 120V 80 ft. Model BGDC1-1A080*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 80 FT Watts: 400 W Amp: 3.3 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $65.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 150W 120V 30 ft. Model BGDC1-1A030*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 30 FT Watts: 150 W Amp: 1.3 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $117.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 560W 120V 80 ft. Model BFPC1-1A080*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 80 FT Watts: 560 W Amp: 4.67 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $98.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 420W 120V 60 ft. Model BFPC1-1A060*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 60 FT Watts: 420 W Amp: 3.5 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $56.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 210W 120V 30 ft. Model BFPC1-1A030*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 30 FT Watts: 210 W Amp: 1.75 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $52.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 168W 120V 24 ft. Model BFPC1-1A024*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 24 FT Watts: 168 W Amp: 1.4 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $38.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 105W 120V 15 ft. Model BFPC1-1A015*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 15 FT Watts: 105 W Amp: 0.88 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $37.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 84W 120V 12 ft. Model BFPC1-1A012*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 12 FT Watts: 84 W Amp: 0.70 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order