Skip to content

Britech

  • $122.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 700W 120V 140 ft. Model BGDC1-1A140*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 140 FT Watts: 700 W Amp: 5.8 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $93.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 500W 120V 100 ft. Model BGDC1-1A100*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 100 FT Watts: 500 W Amp: 4.2 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $78.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 280W 120V 40 ft. Model BFPC1-1A040*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 40 FT Watts: 280 W Amp: 2.34 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $42.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 126W 120V 18 ft. Model BFPC1-1A018*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 18 FT Watts: 126 W Amp: 1.05 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $172.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 1200W 120V 240 ft. Model BGDC1-1A240*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 240 FT Watts: 1200 W Amp: 10.0 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $160.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 1000W 120V 200 ft. Model BGDC1-1A200*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 200 FT Watts: 1000 W Amp: 8.3 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $153.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 900W 120V 180 ft. Model BGDC1-1A180*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 180 FT Watts: 900 W Amp: 7.5 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $133.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 800W 120V 160 ft. Model BGDC1-1A160*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 160 FT Watts: 800 W Amp: 6.7 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $109.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 600W 120V 120 ft. Model BGDC1-1A120*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 120 FT Watts: 600 W Amp: 5.0 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $87.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 400W 120V 80 ft. Model BGDC1-1A080*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 80 FT Watts: 400 W Amp: 3.3 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $65.00

    Britech Therma-Roof Series Resistance Plug-In Heating Cable For Roof and Gutter De-Icing, 150W 120V 30 ft. Model BGDC1-1A030*

    Britech
    Description A Therma-Roof system can help prevent ice dams and icicles by maintaining a continuous path for melt water to drain from the roof. As long as a heated path from the roof to a safe discharge area is maintained, ice dams will not form. The system can be used on roofs and valleys and in downspouts and gutters made from many types of standard roofing materials, including metal, plastic, asphalt and fiberglass shingles. The Therma-Roof heating cable is laid in a "zigzag" fashion along the lower edge of the sloping rood. The heater should extend at least 12 in. (30 cm) above the level of the outer building wall, or 6in. (15cm) in above the snow fence, whichever is the higher, and extend down into the gutter. This will ensure a continuous run off path for melted water. Since this is not a self-regulating cable, it can not overlap at any point! Features 5 Watts per foot. For outdoor applications only. Do not use this product on wooden gutters or downspouts. Roof clips for cable and spacers included. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 30 FT Watts: 150 W Amp: 1.3 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.5" (12mm) Installation Temperature: Min. Installation Temperature: -18°C (0°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $117.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 560W 120V 80 ft. Model BFPC1-1A080*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 80 FT Watts: 560 W Amp: 4.67 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $98.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 420W 120V 60 ft. Model BFPC1-1A060*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 60 FT Watts: 420 W Amp: 3.5 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $56.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 210W 120V 30 ft. Model BFPC1-1A030*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 30 FT Watts: 210 W Amp: 1.75 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $52.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 168W 120V 24 ft. Model BFPC1-1A024*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 24 FT Watts: 168 W Amp: 1.4 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $38.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 105W 120V 15 ft. Model BFPC1-1A015*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 15 FT Watts: 105 W Amp: 0.88 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $37.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 84W 120V 12 ft. Model BFPC1-1A012*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 12 FT Watts: 84 W Amp: 0.70 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $36.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 63W 120V 9 ft. Model BFPC1-1A009*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 9 FT Watts: 63 W Amp: 0.51 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $30.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 42W 120V 6 ft. Model BFPC1-1A006*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 6 FT Watts: 42 W Amp: 0.35 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order
  • $28.00

    Britech Therma-Pipe Series Resistance Plug-In Heating Cable For Pipes, 21W 120V 3 ft. Model BFPC1-1A003*

    Britech
    Description The Therma-Pipe series resistance plug-in heating cable is an economical alternative to self-regulating cables for pipe tracing applications. However, since this is not a self-regulating cable, it can not overlap at any point. It is factory assembled with a 3-prong plug so each cable simply connects to any grounded 120V outlet. Make sure you look at the Product Sheet to choose the correct length of cable needed for your installation! Features 7 Watts per foot. For outdoor applications only. Built-in bi-metal thermostat energizes the cable when the temperature falls below 4 °C (40 °F). For metallic and non-metallic pipes up to 1.5 in (3.8 cm) in diameter. Grounded 3-pronged plug with indicator light to show when the cable is on. Technical Information Length: 3 FT Watts: 21 W Amp: 0.18 A Voltage: 120 V Cable Type: Series Resistance Usage: WS: Wet Test and Weather resistance Min. Bending Radius: 0.3" (8mm) Installation Temperature: Min. Installation Temperature: 0°C (32°F) Operating Temperature: Max. Continuous Operating temperature: 25°C (77°F) Document Product Sheet Installation Manual
    • Available for special order