Test equipment analyze measurements, evaluate electronic signals, trace faults and provide vital information to the installer. Our clamp meters, multimeters, testers, and temperature measurement tools assist in a safe installation for the installer and end user.
Description The IDEAL 61-415 TightSight Split Jaw Meter is a CAT IV 600V, CAT III 1000V auto ranging true root mean square (TRMS) digital fork meter that measures up to 200 Amps AC or DC between the forks. It measures up to 1000V AC and DC, continuity, resistance, capacitance, and diodes via test-leads (included) and detects the presence of voltage between 40V to 600V via a non-contact sensor in the tip of the right fork. The Dual large displays can be backlit, and a built-in flashlight can be illuminated when working in poor or zero lighting conditions. The unit uses an illuminated red LED in the center of the meter and emits audible tones to notify when voltage is above 30 volts, when continuity is detected and when the NCV senses voltage within its set range. The back of the meter has a built-in two position dual probe holder; the lower position allows for probe storage, the higher position allows for testing or measurement holding the meter and secured probe in one hand and the second probe in the other hand, or for both probes to be secured in the tip while conducting measurements. The meter has a hanging strap mount (compatible with all other IDEAL meters with this feature) that allows for a hanging strap (sold separately) to be attached to the meter so it can be hung from a nail, screw or magnetic surface. This meter features HOLD, MIN/MAX, Relative, Range, and selectable Auto Power Off functions. The meter comes with 3 1.5V AAA Batteries and an easy open, fully accessible storage pouch with a belt loop that allows for storage. Features UL Certified CAT IV 600V & CAT III 1000V, measures 0-200 Amps AC/DC and 0-1000 Volts AC/DC Provides True RMS AC voltage and current for accurate measurements on non-linear signals Measures AC/DC Current, AC/DC Voltage, continuity, resistance, capacitance, diodes, and senses AC voltage Built-in probe tip holder and hanging strap clip allows safer, easier measurement and probe storage Built-in Flashlight and Dual backlit displays allow for safer/faster work in poorly lit environments Includes soft case, test leads, and batteries Technical Information CAT Rating (Safety): CAT IV 600V - CAT III 1000V Listing: cULus, CE, RCM Drop Protection: 6.6 ft (2m) Clamp/Jaw Opening: 0.75 in (19mm) AC Voltage: 1000V DC Voltage: 1000V AC Current: 200A DC Current: 200A Ohms: 60MΩ AC Millivolts: Yes DC Millivolts: Yes True RMS: Yes High Voltage Alarm: ACV/DCV | >30V Audible Continuity: Yes Visual Continuity: Yes Backlight: Yes NCV: 40-600V Auto Ranging: Yes Range Hold: Yes Data Hold: Yes Relative: Yes Diode Test: Yes Capacitance Test: 6.000mF Max / Min: Yes Magnetic Strap Mount: Yes (Strap Non Included) Test Probe Holder: Yes Flashlight: Yes Auto-Power Off (APO): Yes APO Disable: Yes Battery Type: 2 x 1.5V AAA (Included) Bottom LCD Display: Yes LCD Display Count: 6000 Warranty: 2-Year Included Accessories: Leads, Case & Batteries Document Spec Sheet Instruction Catalogue Test Lead Selection Chart Warranty
Description The Fluke 233 Digital Multimeter with its removable display gives you the flexibility to take measurements in hard to reach places or in areas with restricted access. You can be in two places at once and reduce the risk of arc flash by separating yourself from hazardous measurement situations. Just connect the meter to the test point and then place the display in a location up to 10 meters (33 ft.) away where you can see it. No more having to stretch into tight spots or hard to reach locations to take measurements. No more having to hold both the meter and the test leads to make a measurement. The Fluke 233 is ideal for any application where the measurement point is separated from controls or where you can't stay close to the meter during measurements due to hazards, moving machinery or in clean rooms. Plus, it features True RMS AC voltage and current for accurate measurements on non-linear signals. Features True RMS Digital Multimeter with detachable display Measures up to 1000 VAC and DC Measures up to 10 A (20 A for 30 seconds) Provides a 10,000 μF capacitance range Measures frequency to 50 kHz Includes a built-in thermometer to measure temperature without a separate instrument Radio transmitter automatically turns off the when the display is connected to the meter so you can use it as a conventional multimeter Easy to read display with large digits and bright backlight Delivers approximately 400 hours of battery life Offers resistance, continuity, and diode test Features a removable magnetic display that can be conveniently mounted where it can be easily seen Low power wireless technology allows the display to be moved up to 10 meters (33 ft.) away from the point of measurement, without causing measurement interference Allows you to take measurements without holding the meter, to improve visual focus on probes and augment safe electrical measurements Provides auto power-off to maximize battery life Features Min/Max, and Average recording to capture variations automatically Technical Information Accuracy specifications DC voltage Range 0.1 mV to 1000 V Accuracy 0.25% + 2 AC voltage Range 0.1 mV to 1000 V Accuracy 1.0% + 3 DC current Range 1 mA to 10 A Accuracy 1.0% + 3 AC current Range 1 mA to 10 A Accuracy 1.5% + 3 Resistance Range 0.1 Ω to 40 MΩ Capacitance Range 1 nF to 9999 μF Resolution 1nF Frequency Range 5 Hz to 50 kHz Resolution 0.01 Hz Counts 6000 Temperature -40°C to +400°C Power AA batteries: Three for main body two for display Battery life 400 hours Wireless frequency 2.4 GHz ISM Band 10 meter range Safety rating CAT IV 600 V , CAT III 1000 V General specifications Basic features AC true-rms Yes Ranging Auto/manual Display Backlight Yes Data storage Min/Max/Avg Yes Other features Battery type AA alkaline Removable display Yes Warranty and protection Safety rating CAT IV 600 V/CAT III 1000 V External protection Rubber overmold Warranty Three-years Size (H x W x L) 5.3 x 9.3 x 19.3 cm (2.08 x 3.6 x 7.6 in) Weight 604 g (1.3 Ib) Document Datasheet User's Manual Quick Reference
Description The Fluke TL75 Hard Point™ Test Leads are a set of comfort grip, PVC-insulated probes. TL75s offer the convenience of a test lead and probe together in one unit with a variety of connections. This set of test leads are recommended for all general-purpose measurements and are compatible with a wide range of Fluke meters and tools. The Fluke TL75 Hard Point™ Test Lead Set is CAT II 1000 V, 10 A rated. When the protective caps are placed on the leads, the ratings jump up to CAT IV 600 V, CAT III 1000 V. Features Test lead and probe in one unit 48 inches (1.22 meter) long CAT II 1000 V, 10 A rated CAT IV 600 V, CAT III 1000 V rated with protective cap CSA Listed
Description The Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display. Use the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces. Your job will get easier when you use the 377 FC clamp meter. The display turns green when a stable FieldSense measurement is detected. Visual Continuity also provides a bright green screen for easy detection of continuity in noisy work areas. With Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows you to gather data as the basis for a preventive maintenance program. Features Complete 3-phase voltage and current tests in 3 easy steps Full set of phase-to-ground and phase-to-phase values calculated and shown on the meter Values are also displayed on your smart phone and saved to the cloud via Fluke Connect software Phase rotation auto-calculated and shown on the Fluke Connect software No more hand-written notes or complicated math. Measure voltage and current with your clamp jaw Faster, safer testing - all without touching a live wire - using FieldSense™ technology Technical Information General specifications General Maximum Voltage between any Terminal and Earth Ground 1000 V Battery Type 2 AA IEC LR6 alkaline Life 200 hour Display Dual readout Automatic Power Off 20 minutes Electrical AC Current: Jaw Range 999.9 A Resolution 0.1 A Accuracy 2 % ±5 digits (45 Hz to 66 Hz) Crest Factor (50/60 Hz) 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2 % for C.F. >2 AC Current: Flexible Current Probe Range 2500 A Resolution 1 A (≤2500 A) 0.1 A (≤999.9 A) Accuracy 3 % ±5 digits (5 Hz to 500 Hz) Crest Factor (50/60Hz) 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2 % for C.F. >2 Position Sensitivity Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5 % B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0 % C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 999.9 A Resolution 0.1 A Accuracy 2 % ±5 digits 1 [1] When using the ZERO function to compensate for offsets AC Voltage: Field Sense Range 1000 V Resolution 1 V (≤1000V) Accuracy ≤4/0 AWG 3 % ±5 digits (45 Hz to 66 Hz) ≥4/0 AWG 5 % ±5 digits (45 Hz to 66 Hz) Position wire as close as possible to jaw opening (see illustration). AC Voltage: Test Leads Range 600.0 V 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1 % ±5 digits (20 Hz to 500 Hz) DC Voltage Range 600.0 V 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1 % ±5 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1 % ±5 digits Amps Frequency: Jaw Range 45 Hz to 66 Hz Resolution 0.1 Hz Accuracy 0.5 % ±5 digits Trigger Level 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥ 5 A 100 Hz to 500 Hz, ≥ 10 A Amps Frequency: Flexible Current Probe Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5 % ±5 digits Trigger Level 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz,≥25 A Resistance Range 60.00 kΩ 6000 Ω 600.0 Ω Resolution 0.1 Ω (≤600.0 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60.00 kΩ) Accuracy 1 % ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤100.0 μF) 1 μF (≤1000 μF) Accuracy 1 % ±4 digits Mechanical Size (L x W x H) 274 mm x 86 mm x 47 mm Weight (with Batteries) 463 g Jaw Opening 34 mm Flexible Current Probe Diameter 7.5 mm Flexible Current Probe Cable Length (head to electronics connector) 1.8 m Rogowski Coil Length 450 mm Environmental Operating Temperature -10 °C to 50 °C Storage Temperature -40 °C to 60 °C Operating Humidity (without condensation) Non condensing (28 °C or <18 °C Ingress Protection IEC 60529: IP30 (jaw closed) Operating Altitude 2000 m Storage Altitude 12 000 m Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2, CISPR 11: Group 1, Class B Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Safety General IEC 61010-1: Pollution degree 2 Measurement IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V Current Clamp for Leakage Current Measurements IEC 61557-13: Class 2, ≤30 A/m Wireless Radio Radio Frequency Certification FCC ID: T68-FBLE IC:6627A-FBLE Frequency Range 2405 MHz to 2480 MHz Output Power <100 mW Radio Frequency Data Radio Frequency Data For Class A Devices SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU. The full text of the EU declaration is available at the following internet address: https://dam-assets.fluke.com/s3fs-public/FLK_RED_1aeng0900.pdf . Document User's manual Quick Reference
Description The Fluke 51 II single input digital thermometer delivers fast response with laboratory accuracy (0.05% + 0.3°C). You can use the 51 II to measure contact temperature on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or E-type thermocouple temperature sensors. The user friendly-front panel and large, backlit display make it easy to view results. And the sleep mode feature preserves battery life to give you a typical thousand hours of operation. Features Single Input digital thermometer for lab, QA, process calibration, food safety and HVAC Measures J, K, T, and E-type thermocouples Presents results in °C, °F, or Kelvin (K) on a large backlit display Includes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events Easy-to-access battery door that allows replacing the battery without breaking the calibration seal Comes with splash- and dust-resistant case protected by an impact-absorbing holster and a three-year warranty Powered by three, standard AA batteries -30- Includes an electronic offset function that compensates for thermocouple errors to maximize overall accuracy Handles temperatures up to 900°C (1600°F) Provides a user-friendly front panel that is easy to set up and operate Offers sleep mode to increase battery life; 1000-hour battery life typical Offers optional ToolPak accessory to hang the thermometer from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation Technical information Specifications Temperature accuracy Above -100°C J, K, T, E, and N-type: ±[0.05% + 0.3°C] 1 R and S-type: ±[0.05% + 0.4°C] 1 Below -100°C J, K, E, and N-types: ±[0.20% + 0.3°C] 1 T-type: ±[0.50% + 0.3°C] Temperature J-type -210°C to 1200°C K-type -200°C to 1372°C T-type -250°C to 400°C E-type -150°C to 1000°C N-type -200°C to 1300°C 1 R and S-type 0°C to 1767°C 1 Temperature scale ITS-90 Applicable standards NIST-175 Display resolution 0.1°C, 0.1 K < 1000 1°C, 1 K ≥ 1000 1. Only the Fluke Models 53 II B and 54 II Bthermometers are capable of measuring N, R, and S-type thermocouples. Environmental Specifications Operating temperature -10°C to 50°C Storage temperature -40°C to 60°C Humidity (without condensation) 0% to 90%; 0°C to 35°C 0% to 70%; 0°C to 50°C Safety Specifications Overvoltage category CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 Agency approvals CE, CSA, TÜV (pending) Mechanical and General Specifications Size (L x W x D) 173 x 86 x 38 mm Weight 400 g Batteries 3 AA batteries; typical 1000-hour life Document User's Manual
Description The Fluke 374 FC, part of the Fluke Connect family of wireless test tools, delivers the standard features you need for everyday troubleshooting. Measure AC and DC current to 600 A with the fixed jaw clamp or add an optional iFlex® flexible current probe to measure all the way to 2500 A. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access tightly packed wires. You can also use the 374 FC to measure AC and DC voltage to 1000 V and resistance to 6000 Ω. The 374 FC is Fluke Connect-enabled to wirelessly transmit results via Bluetooth to Apple and Android devices. That means you can read the results out of the arc flash zone, wearing less PPE. You can even save results to the cloud and create and send reports in email right from the field. Or converse in real-time with ShareLive™ video calls. With True-RMS AC voltage and current measurements, the 374 FC enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 374 FC Clamp Meter is the direct replacement for the Fluke 374 Clamp Meter. What's in the box: 374 FC AC/DC Clamp Meter (1 pair) TL75 test leads Two AA Alkaline batteries (Installed) Soft carrying case Quick Reference Guide Features Advanced clamp meter that transmits measurements to your smartphone via Fluke Connect® for viewing at a safer distance Performs AC and DC current measurements to 600 A, and AC and DC voltage measurements to 1000 V Measures AC current to 2500 A AC with optional iFlex flexible current probe Measures resistance to 6000 Ω with continuity detection Compatible with optional TPAK magnetic hanging strap Comes with soft carrying case, batteries, and three-year warranty Measures capacitance to 1000 µF Features CAT III 1000 V, CAT IV 600 V safety rating Provides True-RMS voltage and current measurements to accurately measure non-linear signals Includes Min/Max/Avg and inrush recording to capture variations automatically Runs on two AA alkaline batteries Technical Information General Specifications AC Current via Jaw Range 600.0 A Resolution 0.1 A Accuracy 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100-500 Hz) Crest Factor (50 Hz/60 Hz) 2.5 @ 600 A Add 2% for C.F. >2 AC Current via Flexible Current Probe Range 2500 A Resolution 0.1 A (≤ 600 A) 1 A (≤ 2500 A) Accuracy 3% ±5 digits (5 – 500 Hz) Crest Factor (50/60Hz) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 Position Sensitivity Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5 % B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0 % C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 600.0 A Resolution 0.1 A Accuracy 2% ±5 digits AC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1.5% ±5 digits (20 Hz to 500 Hz) DC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1% ±5 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1% ±5 digits Resistance Range 6000 Ω Resolution 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) Accuracy 1% ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) Accuracy 1% ±4 digits Mechanical Specifications Maximum voltage between any terminal and earth ground 1000 V Batteries 2 AA, NEDA 15A, IEC LR6 Operating temperature -10 °C to +50 °C Storage temperature -40 °C to +60 °C Operating humidity - non-condensing (< 10°C) ≤90% RH (at 10 °C to 30 °C) ≤75% RH (at 30 °C to 40 °C) ≤45% RH (at 40 °C to 50 °C) Operating altitude 3000 m Storage altitude 12,000 m Size (L x W x H) 249 x 85 x 45 mm Weight 395 g Jaw opening 34 mm Flexible current probe diameter 7.5 mm Flexible current probe cable length (head to electronics connector) 1.8 m Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V IP rating IEC 60529: IP30, non-operating Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C Document User's Manual Datasheet Brochure
Description Having the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 116/323 HVAC Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter. The Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe; no need to carry a separate thermometer. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min/Max/Average readings with elapsed time to record signal fluctuations. Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments. True RMS measurements and optimized ergonomics make the Fluke 323 True RMS Clamp Meter the best general purpose clamp meter for commercial and residential electricians. The Fluke 323 model is ideally suited for current measurements up to 400 A in tight cable compartments. Together, the Fluke 116 HVAC Multimeter and 323 True RMS Clamp Meter give electricians the right tools for the job. Features Fluke 116 Digital Multimeter. Designed by Electricians. Engineered by Fluke. Built-in thermometer for HVAC applications Microamps to test flame sensors Low input impedance: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas Resistance, continuity, frequency and capacitance Min/Max/Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger (ToolPak™) CAT III 600 V safety rated Fluke 323 True-rms Clamp Meter. Rugged. Reliable. Precise. 400 A AC current measurement 600 VAC and DC voltage measurement True RMS AC voltage and current for accurate measurements on non-linear signals Resistance measurement up to 40 kΩ with continuity detection Slim, ergonomic design CAT IV 300 V/CAT III 600 V safety rating 116 Technical Information Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Display 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range/Resolution 600.0 mV / 0.1 mV Accuracy ±([% of reading] + [counts]): 0.5% + 2 DC volts Range/Resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V Accuracy ±([% of reading] + [counts]): 0.5% + 2 Auto volts Range/Resolution 600.0 V / 0.1 V Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) AC millivolts¹ True RMS Range/Resolution 600.0 mV / 0.1 mV Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) AC volts¹ True RMS Range/Resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) Continuity Range/Resolution 600 Ω / 1 Ω Accuracy Beeper on 250 Ω; detects opens or shorts of 500 μs or longer. Ohms Range/Resolution 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ Accuracy 0.9% + 1 Range/Resolution 40.00 MΩ / 0.01 MΩ Accuracy 1.5% + 2 Diode test Range/Resolution 2.000 V / 0.001 V Accuracy 0.9% + 2 Capacitance Range/Resolution 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF Accuracy 1.9% + 2 Range/Resolution > 1000 μF Accuracy 5% + 20% LoZ capacitance Range 1 nF to 500 μF Accuracy 10% + 2 typical Temperature² (Type-K thermocouple) Range/Resolution -40°C to 400°C / 0.1°C Accuracy 1% + 10² Range/Resolution -40°F to 752°F / 0.2°F Accuracy 1% + 18² AC μamps True RMS (45 Hz to 500 Hz) Range/Resolution 600.0 μA / 0.1 μA Accuracy 1.0% + 2 DC μamps Range/Resolution 600.0 μA / 0.1 μA Accuracy 1.0% + 2 Hz (V or A input)² Range/Resolution 99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz Accuracy 0.1% + 2 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. • Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. • Temperature Range/Resolution: -40°F to 752°F / 0.2°F Mechanical and General Specifications Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) Weight 550 g Warranty 3 years 323 Technical Information Specifications AC current Range 400.0 A Accuracy 2% ±5 digits (45 Hz to 65 Hz) 2.5% ±5 digits (65 Hz to 400 Hz) AC voltage Range 600.0 V Accuracy 1.5% ±5 digits DC voltage Range 600.0 V Accuracy 1.0% ±5 digits Resistance Range/Resolution 400.0 Ω/ 4000 Ω Accuracy 1.0% ±5 digits Continuity ≤ 70 Ω AC response True-rms Data hold Yes Size H x W x D (mm) 207 x 75 x 34 Max wire diameter 30 mm (600 MCM) Weight 265 g Category rating CAT III 600 V CAT IV 300 V Warranty Two-year Document 323 User's Manual 323 Quick Reference 323 Brochure 116 Quick Reference 116 User's Manual
Description Now one technician can do jobs that would otherwise require two people. Clamp the Fluke 381 around a conductor, remove the display and walk across the room to operate controls or remove protective equipment, all while watching real-time readings. The iFlex® Flexible Current Probe (included) expands the measurement range to 2500 A AC while providing increased display flexibility. With a cord that runs 6 feet, you can finally measure those tight spaces, awkward sized conductors and disorganized wires. Features Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement with measurement accuracy Removable magnetic display can be mounted where it is easily seen iFlex® Flexible Current Probe expands the measurement range to 2500 A AC CAT IV 600 V, CAT III 1000 V Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it Ergonomic design fits in your hand and can be used while wearing protective equipment Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement Three-year warranty Technical Information Electrical Specifications AC Current via Jaw Range 999.9 A Resolution 0.1 A Accuracy 2% ± 5 digits (10-100 Hz) 5% ± 5 digits (100-500 Hz) Crest Factor (50/60 Hz) 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2% for C.F. > 2 AC Current via Flexible Current Probe Range 999.9 A / 2500 A (45 Hz – 500 Hz) Resolution 0.1 A / 1 A Accuracy 3% ± 5 digits Crest Factor (50/60 Hz) 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 Position Sensitivity Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5% B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0% C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0% Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 999.9 A Resolution 0.1 A Accuracy 2% ± 5 digits AC Voltage Range 600 V /1000 V Resolution 0.1 V / 1 V Accuracy 1.5% ± 5 digits (20 – 500 Hz) DC Voltage Range 600.0 V /1000 V Resolution 0.1 V / 1 V Accuracy 1% ± 5 digits Frequency – Via Jaw Range 5.0 – 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ± 5 digits Trigger Level 5 – 10 Hz, ≥ 10 A 10 – 100 Hz, ≥ 5 A 100 – 500 Hz, ≥ 10 A Frequency via Flexible Current Probe Range 5.0 to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ± 5 digits Trigger Level 5 to 20 Hz, ≥ 25 A 20 to 100 Hz, ≥ 20 A 100 to 500 Hz, ≥ 25 A Resistance Range 600 Ω/6 kΩ/60 kΩ Resolution 0.1 Ω/1 Ω/10 Ω Accuracy 1% ± 5 digits Mechanical Specifications Size (L x W x H) 277 x 88 x 43 mm (55 mm for remote unit) Weight 350 g Jaw Opening 34 mm Flexible Current Probe Diameter 7.5 mm Flexible Current Probe Cable Length (head to electronics connector) 1.8 m Environmental Specifications Operating Temperature -10°C to +50°C Storage Temperature -40°C to +60°C Operating Humidity Non condensing (< 10°C) ≤ 90% RH (at 10°C to 30°C) ≤ 75% RH (at 30°C to 40°C) ≤ 45% RH (at 40°C to 50°C) (Without Condensation) Operating Altitude 2,000 meters Storage Altitude 12,000 meters EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID: T68-F381 RSS-210 IC: 6627A-F381 Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C Wireless Frequency 2.4 GHz ISM Band 10 meter range Safety Compliance ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV. Double Insulation Clearance Per IEC 61010-2-032 Double Insulation Creepage Per IEC 61010-1 Agency Approvals Document User's Manual Quick Reference
Description The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity. Find the cause of difficult problems The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it. Measure: Voltage to 1000 V AC or DC Resistance to 60 kΩ with continuity detection Min, max, average, and inrush recording to capture variations automatically 500 mV DC measurement range to interface with other accessories 1000 μF capacitance measurement Work safely and conveniently The 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool. The included 18-inch or 36-inch iFlex flexible current probe provides easier access to large conductors in tight spaces. The flexible probe: Expands the measurement range to 2500 A AC Allows frequency measurement to 500 Hz with body jaw and iFlex Features Measures AC/DC current with included 18-inch or 36-inch iFlex current probe VFD low pass filter for accurate measurements of non-linear signals Remotely log, trend and monitor to pinpoint intermittent faults Inrush measurement to filter out noise and capture starting current Technical Information General Specifications AC Current via Jaw Range 999.9 A Resolution 0.1 A Accuracy 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100-500 Hz) Crest Factor (50 Hz/60 Hz) 3 @ 500 A 2.5 @ 600 A Add 2% for C.F. >2 AC Current via Flexible Current Probe Range 2500 A Resolution 0.1 A (≤ 600 A) 1 A (≤ 2500 A) Accuracy 3% ±5 digits (5 – 500 Hz) Crest Factor (50/60Hz) 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 i2500-10 Flex i2500-18 Flex i2500-36 Flex A Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm) 4.8 in (122.2 mm) Error ±0.5 % ±0.5 % ±0.5 % B Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm) 5.3 in (133.6 mm) Error ±1.0 % ±1.0 % ±1.0 % C Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm) 5.8 in (147.6 mm) Error ±2.0 % ±2.0 % ±2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 999.9 A Resolution 0.1 A Accuracy 2% ±5 digits AC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1% ±5 digits (20 Hz to 500 Hz) DC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1% ±5 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1% ±5 digits Frequency via Jaw Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ±5 digits Trigger level 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥5 A 100 Hz to 500 Hz, ≥10 A Frequency via Flexible Current Probe Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ±5 digits Trigger level 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A Resistance Range 60 kΩ Resolution 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60 kΩ) Accuracy 1% ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) Accuracy 1% ±4 digits Mechanical Specifications Maximum voltage between any terminal and earth ground 1000 V Batteries 2 AA, NEDA 15A, IEC LR6 Operating temperature -10 °C to +50 °C Storage temperature -40 °C to +60 °C Operating humidity - non-condensing (< 10°C) ≤90% RH (at 10 °C to 30 °C) ≤75% RH (at 30 °C to 40 °C) ≤45% RH (at 40 °C to 50 °C) Operating altitude 2000 m Storage altitude 12,000 m Size (L x W x H) 249 x 85 x 45 mm Weight 395 g Jaw opening 34 mm Flexible current probe diameter 7.5 mm Flexible current probe cable length (head to electronics connector) 1.8 m Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V IP rating IEC 60529: IP30, non-operating Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C Document User's Manual Datasheet Brochure
Description Keep yourself safe. Find hidden problems faster. Put the paperwork down. Fluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance. Add diagnostics with Fluke Connect The Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone. Includes: Remote probe Test leads Alligator clips K-type thermocouple Soft case User documentation Features Safety first. Keep yourself out of harm’s way by monitoring your test measurements remotely. Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone. Quickly find problems by saving and comparing measurements over time on a wireless device. PI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster Memory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time Temperature compensation to establish accurate baselines and relevant historical comparisons Historical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately) Provides memory storage through Fluke Connect Measurements to eliminate the need to write down results Includes live circuit detection to prevent insulation test if voltage >30 V is detected Provides automated temperature compensation to establish accurate baselines Supports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect® Assets (sold separately) Incorporates VFD low-pass filter for accurate variable frequency motor drive measurements Includes auto-discharge of capacitive voltage for added user protection Measures ac/dc voltage, dc millivolts, ac/dc milliamps, resistance, and continuity Includes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing reading Automatically powers off to save battery power Comes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty. Technical Information Electrical Specifications AC voltage measurement Range 600.0 mV Resolution 0.1 mV Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 6.000 V Resolution 0.001 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 60.00 V Resolution 0.01 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 600.0 V Resolution 0.1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹ 1000 V Resolution 1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹ ¹ 1 kHz bandwidth Low-Pass Filter Voltage Range 600.0 mV Resolution 0.1 mV Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 6.000 V Resolution 0.001 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 60.00 V Resolution 0.01 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 600.0 V Resolution 0.1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 1000 V Resolution 1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) DC Voltage Measurement Range Resolution Accuracy ±(% of Rdg + Counts) 6.000 V dc 0.001 V ±(0.09% + 2) 60.00 V dc 0.01 V ±(0.09% + 2) 600.0 V dc 0.1 V ±(0.09% + 2) 1000 V dc 1 V ±(0.09% + 2) Input impedance 10 MΩ (nominal), 60 dB @ 50 Hz or 60 Hz Common mode rejection ratio >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance) Accuracies apply to ± 100% of range DC Millivolts Measurement Range Resolution Accuracy ±(% of Rdg + Counts) 600.0 mVdc 0.1 mV ±(0.1% + 1) DC and AC Current Measurement AC 45 Hz to 1000 Hz Range 400 mA Resolution 0.1 mA Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹ Burden voltage (Typical) 2 mV/mA Range 60 mA Resolution 0.01 mA Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹ Burden voltage (Typical) 2 mV/mA DC Range 400 mA Resolution 0.1 mA Accuracy ±(% of Rdg+Counts) ±(0.2% + 2) Burden voltage (Typical) 2 mV/mA Range 60 mA Resolution 0.01 mA Accuracy ±(% of Rdg+Counts) ±(0.2% + 2) Burden voltage (Typical) 2 mV/mA Overload 600 mA for 2 minutes maximum Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3. ¹ 1 kHz bandwidth Ohms Measurement Range Resolution Accuracy +(% of Rdg+Counts)¹ 600.0 Ω 0.1 Ω ±(0.9% + 2) 6.000 kΩ 0.001 kΩ ±(0.9% + 2) 60.00 kΩ 0.01 kΩ ±(0.9% + 2) 600.0 kΩ 0.1 KΩ ±(0.9% + 2) 6.000 MΩ 0.001 MΩ ±(0.9% + 2) 50.0 MΩ ² 0.01 MΩ ±(1.5% + 3) Overload protection 1000 V rms or dc Open circuit test voltage 1 m sec Frequency Measurement Range Resolution Accuracy ±(% of Rdg+Counts) 99.99 Hz 0.01 Hz ±(0.1% + 1) 999.9 Hz 0.1 Hz ±(0.1% + 1) 9.999 kHz 0.001 kHz ±(0.1% + 1) 99.99 kHz 0.01 kHz ±(0.1% + 1) Frequency Counter Sensitivity 600.0 mV ac V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 100.0 mV V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz 150.0 mV DC Trigger Levels¹ to 20 kHz² NA 6.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 1.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz 1.5 V DC Trigger Levels¹ to 20 kHz² -400.0 mV and 2.5 V 60.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 10.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz 36.0 V DC Trigger Levels¹ to 20 kHz² 1.2 V and 4.0 V 600.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 100.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz - DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V 1000.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 300.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz - DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V ¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy ² Usable to 100 kHz with full scale input Capacitance Range Resolution Accuracy ±(% of Rdg+Counts) 1000 nF 1 nF ±(1.2% + 2) 10.00 μF 0.01 μF ±(1.2% + 2) 100.0 μF 0.1 μF ±(1.2% ±90 counts) 9999 μF 1 μF ±(1.2% ±90 counts) Temperature Measurement Range Resolution Accuracy ±(% of Rdg+Counts)¹ -40 ° C to 537 ° C 0.1 °C ±(1% + 10 counts) -40 ° F to 998 ° F 0.1 °F ±(1% + 18 counts) ¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument Insulation Specifications Measurement range 0.01 MΩ to 2 GΩ Test voltages 50, 100, 250, 500, 1000 V Test voltage accuracy +20%, -0% Short-circuit test current 1 mA nominal Auto discharge Discharge time 30 V prior to initialization of test Maximum capacitive load Operable with up to 1 μF load Output Voltage 50 V (0% to +20%) Display range 0.01 to 6.00 MΩ Resolution 0.01 MΩ Test current 1 mA @ 50 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) Display range 6.0 to 50.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 50 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) 100 V (0% to +20%) Display range 0.01 to 6.00 MΩ Resolution 0.01 MΩ Test current 1 mA @ 100 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) Display range 6.0 to 60.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 100 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) Display range 60 to 100 MΩ Resolution 1 MΩ Test current 1 mA @ 100 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) 250 V (0% to +20%) Display range 0.1 to 60.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 250 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 60 to 250 MΩ Resolution 1 MΩ Test current 1 mA @ 250 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) 500 V (0% to +20%) Display range 0.1 to 60.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 500 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 60 to 500 MΩ Resolution 1 MΩ Test current 1 mA @ 500 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) 1000 V (0% to +20%) Display range 0.1 to 60.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 1 MΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 60 to 600 MΩ Resolution 1 MΩ Test current 1 mA @ 1 MΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 0.6 to 2.0 GΩ Resolution 100 MΩ Test current 1 mA @ 1 MΩ Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts) General Specifications Maximum voltage applied to any terminal and common 1000 V Storage temperature -40 °C to 60 °C (-40 °F to 140 °F) Operating temperature -20 °C to 55 °C (-4 °F to 131 °F) Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures 28 °C (82 °F) Relative humidity Noncondensing 0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F) 0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F) 0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F) Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument Radio frequency communication 2.4 GHz ISM Band Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE Electromagnetic Compatibility International IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected. Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Enclosure protection IEC 60529: IP40 (non-operating) Safety IEC 61010-1 Pollution Degree 2 IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V Batteries Four AA batteries (IEC LR6) Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) Weight 550 g (1.2 lb) Altitude Operating 2000 m Storage 12,000 m Over-range capability 110% of range except for capacitance which is 100% Frequency overload protection <107 V Hz Fuse protection for mA input 0.44A, 1000 V, IR 10 kA Document Brochure Quick Reference User's Manual
Description The Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications. Take advantage of the 1507 full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and light weight make it easy to pack and use. Additional features, like the remote probe, save both time and money especially when performing repetitive tests. And its reasonable price and rugged reliability make it an excellent value. Includes: Remote probe Test leads Test probes Alligator clips User documentation Features Performs insulation tests from 0.01 MΩ to 10 GΩ Includes live circuit detection to prevent insulation test if voltage >30 V is detected Includes auto-discharge of capacitive voltage for added user protection Measures AC/DC voltage from 0.1 V to 600 V and resistance from 0.01 Ω to 20.00 kΩ Provides lo-ohms earth-bond continuity (200 mA) Simplifies repetitive or hard-to-reach testing with the remote test probe Saves battery power with auto power off Presents results on a large, backlit display Features CAT IV 600 V overvoltage category rating Comes with remote probe, test leads, test probes, alligator clips and one-year warranty Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work Runs on four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests Technical Information AC/DC Voltage Measurement Accuracy Range: 600V Accuracy Resolution: 0.1V Input Impedance: 3 MΩ (nominal), 60 dB at DC, 50 or 60 Hz Overload protection :600 V rms or DC Earth Bond Resistance Measurement Range/Resolution: 20.00 Ω / 0.01 Ω, 200.0 Ω / 0.1 Ω, 2000 Ω / 1.0 Ω, 20.00 kΩ / 0.01 kΩ Accuracy: ±(1.5% + 3) Overload protection: 2 V rms or DC Open circuit test voltage: > 4.0 V, 200.0 mA Insulation Specifications Measurement range: 0.01 MΩ to 10 GΩ Test voltage: 50 V, 100 V, 250 V, 500 V, 1000 V Test voltage accuracy: + 20%, - 0% Short circuit current: 1 mA nominal Auto discharge: Discharge time 30 V prior to initialization of test Maximum capacitive load: Operable with up to 1 µF load Measure accuracy: 50 V ±(3% + 5), 100 V ±(3% + 5), 250 V ±(1.5% + 5), 500 V ±(1.5% + 5), 1000 V ±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ General Specifications Maximum voltage applied to any terminal: 600 V AC rms or DC Storage temperature: -40°C to 60°C (-40°F to 140°F) Operating temperature: -20°C to 55°C (-4°F to 131°F) Temperature coefficient: 0.05 x (specified accuracy) per °C for temperatures 28°C ( 82°F) Relative humidity: 0% to 95% @ 10°C to 30°C (50°F to 86°F), 0% to 75% @ 30°C to 40°C (86°F to 104°F), 0% to 40% @ 40°C to 55°C (104°F to 131°F) Vibration: Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument Shock: 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) Electromagnetic compatibility: In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) Safety: Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) Certifications: CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition Batteries: Four AA batteries (NEDA 15A or IEC LR6) Size (H x W x L): 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) Weight: 550 g (1.2 lb) IP rating: IP40 Altitude: Operating 2000 m CAT IV 600 V, 3000 m CAT III 600 V - Non-operating (storage) 12,000 m Over-range capability: 110% of range Included accessories: TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe Document Brochure Quick Reference Owner's manual
Description The Klein Tools Coax Explorer® 2 verifies proper continuity of F-connector coaxial cables and maps their location. The color-coded remotes allow for up to four cables to be tested and mapped, displaying cable status via LED indicators - PASS, OPEN, or SHORT - that also identify the cable/remote location. This compact tester fits in your pocket. Features Cable tester tests coaxial cable and maps up to 4 locations Simple push button operation Easy-to-read LED panel indicates PASS, OPEN or SHORT conditions and the location of each cable Color-coded push-on remotes allow for up to four cables to be tested and mapped Test remotes and F-adapter snap into the remote holder and clip onto the tester for easy access and storage Includes removable, snap-on remote holder, 4 color-coded push-on remotes, F adapter and batteries Uses 2 replaceable AAA batteries Note: Does not work through cable splitters Technical Information Type: Cable Tester Application: Wire Tracing of Coaxial Cables Special Features: 4 Color-Coded Push-on Remotes Cable Type: RG59, RG6/6Q, RG7, RG11 Overall Length: 5.75'' (14.6 cm) Overall Height: 1'' (2.5 cm) Overall Width: 2.313'' (5.9 cm) Test-n-Map ID Remotes: 4 (Included) Location ID: 4 Batteries: 2 x AAA Connection & Adapter Types: Coax F Adapters Included: Batteries, 4 Colored Push-on Remotes, F-adapter, Snap-on Remote Holder Document Brochure Instruction
Description The Klein Tools Plumber's Borescope provides a complete view of interior drains, pipes and other plumbing systems. It comes with a 4.9-Foot (1.5 m) armored snake, magnet, hook, and mirror attachments. It has a 5.5 mm waterproof (IP67) camera with adjustable LEDs and four brightness levels. It features a 4.3-Inch color LCD monitor with 1280 x 720 resolution, three-times zoom, and 180-Degree screen view rotation. View captured videos and images on the display or transfer them to your PC via USB-C. Features Borescope features compact 5.5 mm water-resistant camera (IP67 for camera head and cable) with 720p resolution 4.3-Inch color LCD screen for clear viewing 4.9-Foot armored snake easily navigates through areas that are unreachable or difficult to view Includes hook, magnet, and mirror attachments to tackle wide variety of applications Camera is surrounded by 6 bright LED lights adjustable to 4 output levels Self-storing kickstand can be easily extended to free both hands for navigation Transfer photos/videos via USB-C interface Technical Information Type: USB-C Borescope Application: Electrical, HVAC, Plumbing, Aircraft Special Features: 5' (1.5 m) Armored Gooseneck and 6 LED Lights Cable Length: 5' (1.5m) Overall Length: 6.55'' (16.6 cm) Overall Height: 1.51'' (3.8 cm) Overall Width: 3.19'' (8.1 cm) Camera Head Diameter: 0.22'' (5.5 mm) Auto-Power Off: No Data Logging: No Material: PC/ABS or PC/ABS with TPE Overmold Batteries: Lithium-ion Battery Life: 3 hr Display: Color LCD monitor with 480p resolution Screen Resolution: 480p Camera Resolution: 720p Digital Zoom: Yes Recording Capability: Still Image and Video IP Rating: IP67 (Camera Only) Included: Borescope, 5.5mm camera probe with 5' (1.5m) Cable, USB Cable, Camera Accessories (Magnet, Hook, Mirror), and Carrying Case Weight: 8.6 oz (244 g) UPC: 092644694639 Document Brochure Manual
Description Keep your Scout® Pro 3 tester, smart remotes and accessories safe with this durable polyester carrying case. Designed for use with the Scout® Pro 3 tester and the Test + Map™ remotes. This flexible case can accommodate various products and configurations. Cushioned foam insulates the tools during transport. Benefits Replacement case for Scout® Pro 3 Tester Remote Update Kit (Cat. No. VDV770-850) and Starter Kit (VDV501-853) Custom designed compartments hold tester and remotes securely Durable nylon withstands scratches and tears EVA foam cushions and protects equipment Dual zipper-pulls for quick access Flexible case can hold a variety of products and configurations Designed to hold Cat. Nos. VDV770-850, VDV501-853 (sold separately) Note: Products in photos not included Technical Information Type: Foam Cushioned Case Application: Scout® Pro 3 Tester and Remote Storage Special Features: Custom Designed Comparments Overall Length: 13'' (33 cm) Overall Height: 9'' (23 cm) Overall Width: 4.4'' (11 cm) Material: EVA Foam, Nylon Color: Black Closure Type: Zipper Total Cubic Area: 515 in³ Handle Material: Polyester Insulation: Die Cut Foam Insert Padding For Use With: Cable Tester Kits with Scout® Pro 3 Tester (Cat. Nos. VDV501-851 and VDV501-853) Weight: 2.2 lb (1 kg) UPC: 092644583476
Description Replacement snake inspection camera for Klein Tools Utility Borescope (Cat. No. ET17). The 10-Foot (3 m) nylon snake navigates through twists, turns, and bends. The tip of the snake features a 5.5 mm water-resistant (IP67) camera surrounded by 6 bright LED lights adjustable to 4 output levels. ***THIS IS THE CABLE ONLY*** Features Replacement 10-Foot (3 m) nylon snake compatible with Cat. No. ET17 Utility Borescope Compact 5.5 mm water-resistant single-lens camera (IP67 snake) High resolution (720p) camera for high visual clarity in any conditions 6 bright LEDs with 4 adjustable output levels for clear images even in dark conditions 10-Foot (3 m) nylon snake navigates through twists, turns, and bends for ultimate access and control Technical Information Type: Replacement Snake Application: Electrical, HVAC, Plumbing, Aircraft Special Features: 10' (3 m) Nylon Gooseneck, 6 LED Lights Overall Length: 10' (3 m) Overall Height: 0.5'' (1.3 cm) Overall Width: 0.22'' (0.6 cm) Material: Nylon Camera Head Diameter: 5.5 mm Dimensions: 0.5'' x 10' x 0.22'' (1.3 cm x 3 m x 0.6 cm) Video Output: USB-C Camera/Probe Light: LED For Use With: ET17 Utility Borescope Included: Borescope Camera with Attached 10' Snake Weight: 4.2 oz (119 g) UPC: 092644694622 Document Spec Sheet
Description The. GT - 10 is a simple instrument designed to detect nearly all, probable and common, improper wiring conditions. *It will not detect a combination of defects. Features Circuit verifying polarity cube troubleshoots 120 V AC grounded outlets Light sequence indicates correct/incorrect wiring Technical Information Application: Cube polarity tester for 120 V AC grounded outlets Standard: ETL Dimensions: 6.9 x 3.9 x 1.4 IN
Description Replacement Leads for the Digital Tone Generator (Cat. No. VDV500-163). Includes two integrated alligator clips with angled bed of nails (ABN) and one RJ45 cable. Features Replacement Leads for Digital Tone Generator (Cat. No. VDV500-163) Includes two integrated alligator clips with angled bed of nails (ABN), one for positive (red) and one for negative (black) Alligator clips easily attach and detach from the tone generator using banana clips Alligator clips include dust caps to prevent dirt and dust from getting into the banana clips Leads are made from 18 AWG wire Alligator clips measure 24-Inch (61 cm) from end to end Includes one RJ45 cable Technical Information Type: Replacement Leads Application: Wire Toning Special Features: Replacement Leads Overall Length: 9.1'' (23.1 cm) Overall Height: 13'' (33 cm) Overall Width: 0.8'' (2 cm) Material: Brass Included: (2) Alligator Clips with ABN, (1) RJ45 Cable Weight: 3.4 oz
Description Replacement tip for the Digital Tracing Probe (Cat. No. VDV500-223) traces wires on active and inactive networks. The tip is responsive, durable, non-metallic and conductive. Twist and lock tip to install, without the need for tools. Features Replacement tip for the Digital Tracing Probe (Cat. No. VDV500-223) Tool-less, twist-and-lock replaceable tip Responsive, durable, non-metallic, conductive tip Traces wires and cables on active and inactive networks when used with the Digital Tracing Probe (Cat. No. VDV500-223) To remove tip, turn counterclockwise a quarter turn and pull gently to remove Insert new tip with key in proper orientation and push gently Rotate a quarter turn clockwise to lock into place Technical Information Type: Replacement Tip Application: Wire Tracing Special Features: Replaceable Overall Length: 0.4'' (1 cm) Overall Height: 1.6'' (4.1 cm) Overall Width: 0.4'' (1 cm) Material: Polyamide Weight: 0.1 oz (3 g) Document
Description This custom easy access zipper pouch holds both the Tone and Probe PRO kit (Cat No.VDV500-820). The convenient padded divider keeps the tone generator (Cat No. VDV500-063) and tracing probe (Cat No.VDV500-123) separated. Additional padding adds extra protection. Durable nylon can withstand the most rigorous jobsite. Features Custom zipper pouch for convenient storage For use with the Tone and Probe PRO Kit (VDV500-820) Holds both the Tone-PRO (VDV500-063) and Probe-PRO (VDV500-123) - sold separately Padded divider keeps tools separate Padded outside for added protection 11.2-Inch x 5.9-Inch x 0.4-Inch Black with Klein Tools logo Technical Information Type: Replacement Pouch Application: Storage Special Features: Padded, Padded Divider Interior Pockets: 2 Number of Pockets: 2 Overall Length: 11.2'' (28.4 cm) Overall Height: 5.9'' (15 cm) Overall Width: 0.4'' (1 cm) Material: Nylon Color: Black Closure Type: Zipper Total Cubic Area: 2.3 cu ft (65.1 L) Insulation: No For Use With: Cat. Nos. VDV500-123, VDV500-063, and VDV500-820 Weight: 0.1 lb (0.05 kg) Document Brochure
Description Klein Tools ET16 is a USB Type-C borescope with a 9 mm camera surrounded by 6 LEDs attached to a 10-Foot (3.0 m) armored gooseneck cable. The digital camera has a USB Type-C (and micro-USB) connection for most Android® (OTG 4.0 or higher) smartphones and devices. The camera and video output are displayed on the Android® device using the free Klein Tools Borescope App, available for download at www.KleinTools.com. Benefits Borescope connects to Android on-the-go (OTG) version 4.0 or higher devices; NOT for iPhones or iPads Waterproof IP67 9 mm camera for high quality 640 x 480 pixel images Capture and share images and video via text or email using the Klein Tools free app Armored 10-Foot (3 m) gooseneck cable for extended reach Six white LEDs with adjustable brightness control for best pictures Direct USB Type-C connection with adapter for micro-USB No batteries; powered by device connection Includes borescope, carrying case, micro-USB adapter, and instruction manual Technical Information Type: USB Type-C or Micro-USB for Android Application: Electrical, HVAC, Plumbing, Aircraft Special Features: 10' (3 m) Armored Gooseneck and 6 LED Lights Overall Length: 3.7'' (9.4 cm) Overall Height: 0.95'' (2.4 cm) Overall Width: 1.3'' (3.3 cm) Camera Head Diameter: 0.35'' (9 mm) Auto-Power Off: No Data Logging: No Material: ABS and Electrical Components Display: Via Smartphone App Screen Resolution: 640 x 480 Max Digital Zoom: Yes Recording Capability: Still Image and Video IP Rating: IP67 (Camera Only) Included: Borescope with 10' Gooseneck, USB Adapters, Carrying Case, and Instruction Manual Weight: 12.5 oz (354 g) Documents Brochure Instruction Manual
Description The IDEAL 61-847 Dual Laser Targeting Infrared Thermometer (IRT) is a non-contact temperature sensing meter. Its dual lasers define the outside edges of the area whose temperature will be measured. The IRT displays the actual measurement as well as 4 selectable additional measurements. HI and LO alarms and emissivity are all user programmable. The IRT measures temperatures from -26° to 932°F (-32° to 500°C). The LCD backlit display can be illuminated when working in poor or zero lighting conditions and the laser targeting system can be turned on and off at the user's discretion. The unit uses two red lasers located above and below the IR sensor to accurately outline the area being measured. An industrial grade overmolding and lanyard tie off point enhance grip and drop protection. This meter features HOLD, MIN/MAX/AVG/DIF, High/Low Visual and Audible Alarms, Lock Measurement for temperature measurement over time (unit can be mounted on a standard camera tripod), adjustable Emissivity, and selectable Auto Power Off functions. The meter comes with 2 1.5V AAA Batteries. Features UL Certified, complies with IEC/EN 60825-1 and 21 CFR 1010/1040 Measurement Range: -26° to 932°F (-32° to 500°C) 12:1 Distance to Spot size Dual Laser Targeting System outlines the specific area being measured for accurate surface temperature measurements. Large, easy to read LCD with integrated selectable back light allow for safer/faster work in poorly lit environments Over molded Industrial design and lanyard tie off point enhance gripping and allows the meter to withstand a 6.6-foot (2 m) drop Programable Hi and Low Temperature alarms, emissivity, degrees F or C, audible alarm, and lock measurement setting. Secondary Screen displays Max, Min, Average, and Difference values of the most recent scan. Audible High/Low Alarm Setting allows the meter to be operated with a visual only indication when working in noise sensitive/noise restricted area with the simple press of a button. Scan mode constantly updates the temperature readings in the display as different targets are scanned Lock Measurement function and Standard Tripod Mount Thread allow for easy temperature monitoring from 1 minute to 5 hours. Includes 2 1.5V AAA batteries Technical Information Certification: CLASS 2, IEC 60825-1:2014 Wavelength: 630nm-670nm Output: < 1mW Listing: cULs, CE Drop Protection: 6.6 ft (2m) Optical Resolution (Distance-to-spot): 12 : 1 Measurement Range: -26°F - 935°F ( -32°C to 500°C) Laser Targeting: Dual Auto Scan: Yes Max/Min/Avg/Diff: Yes High/Low Alarm: Yes Data Hold: Yes Lock-On (for continuous measurements): Yes Emissivity: 0.10 - 1.00 Adjustable Backlit Display: Yes Display: LCD Auto Power-Off: Yes Selectable Celsius / Fahrenheit: Yes Battery Type: 2 x 1.5V AAA Low Battery Indicator: Yes Response Time: 250 ms Spectral Response: 8 to 14µm Warranty: 2-Year Document Spec Sheet Instruction Manual Warranty
Description The IDEAL 61-357 Digital Multi Meter is a CAT IV 600 CAT III 1000V rated auto ranging true root mean square (TRMS) digital multi meter that measures up to 10 Amps AC and DC current via the test leads in series with the load. It measures up to 1000V AC and DC, LoZ (low impedance) AC V, frequency, resistance, continuity, capacitance, and diodes via test-leads (included) and measures temperature (⁰F/⁰C) via a K-Type thermocouple (included). It's capable of detecting the presence of voltage between 40V to 600V via a non-contact sensor in the top center of the meter. It's display features a digital readout and also an analog bargraph representation and can be backlit. The unit uses an illuminated red LED in the center of the meter and emits audible tones to notify when voltage is above 30 volts, when continuity is detected and when the NCV senses voltage within its set range. The rubber boot has two probe storage points has built-in probe tip holders to allow measurements while holding the meter in one hand and the second lead in the other hand. The meter has a hanging strap mount (compatible with all other IDEAL meters with this feature) that allows for a hanging strap (sold separately) to be attached to the meter so it can be hung from a nail, screw or magnetic surface. An industrial grade over molding enhances grip and drop protection. This meter features HOLD, MIN/MAX, Relative, Range, and selectable Auto Power Off functions. The meter comes with 3 1.5V AAA Batteries and an easy open, fully accessible storage pouch with a belt loop that allows for meter, probes and thermocouple storage. Features UL Certified CAT IV 600V CAT III 1000V AC/DC 10A AC/DC TRMS Auto Ranging Digital Multimeter with Analog Bargraph on Display Provides True RMS AC voltage and current for accurate measurements on non-linear signals Measures AC/DC Current, AC/DC Voltage, Lo Z, frequency, resistance, continuity, capacitance, diodes, temperature and senses AC voltage. Built-in probe tip holder and hanging strap clip allows safer, easier measurement Large easy to read l backlit display, allows for safer/faster work in poorly lit environments Industrial design of removeable rubber boot enhances gripping and allows the meter to withstand a 6.6-foot (2 m) drop Includes soft case, test leads, batteries, and K-Type Thermocouple Combined LCD Digital readout and analog bar graph display. Technical Information CAT Rating (Safety): CAT IV 600V - CAT III 1000V Listing: cULus, CE, RCM Drop Protection: 6.6 ft (2m) Ingress Protection: IP52 AC Voltage: 1000V DC Voltage: 1000V AC Current: 10A DC Current: 10A Ohms: 60MΩ AC Millivolts: 6000 DC Millivolts: 6000 AC Milliamps: 6000 DC Milliamps: 6000 AC Microamps: 6000 DC Microamps: 6000 True RMS: Yes High Voltage Alarm: ACV/DCV | >30V Audible Continuity: Yes Visual Continuity: Yes Backlight: Yes Temperature: -40°F to 1832°F (-40°C to 1000°C) Low Impedance (LoZ): Yes NCV: Yes Auto Ranging: Yes Range Hold: Yes Data Hold: Yes Dioe Test: Yes Capacitance Test: 6000 μF Frequency / Duty Cycle: 10 Hz - 9.99KHz Max / Min: Yes Magnetic Strap Mount: Yes Strap not included) Test Probe Holder: Yes Auto-Power Off (APO): Yes APO Disable: Yes Low Battery Indication: Yes Battery Type: 3x 1.5V AAA (Included) LCD Display Count: 6000 Lead Warning: Yes Fuse Notification: Yes Bar Graph: Yes Warranty: 2-Year Included Accessories: Leads, Case, Temp. Sensor and Thermocouple (TC-757) Document Spec Sheet Catalogue Instruction Warranty Test Lead Selection Chart
Description The Fluke 561 IR contact thermo meter combines the temperature measurement functions that industrial, electrical, and HVAC/R professionals need in one tool. It is an IR thermometer for non-contact measurements, with K-type thermocouple capability for contact temperature measurement. It's fast, efficient, and easy to use, saving you valuable time and effort. Use the 561 IR capabilities to scan large areas or small objects quickly and efficiently, without having to shut down equipment. Measure hot, moving, electrically energized, and hard-to-reach objects instantly. Check motors, insulation, breakers, radiant heating, pipes, corroded connections, and wires. Plus, scan ducts, and other hard-to-reach objects from the floor and leave your ladder in the truck. You can also use the Fluke 561's handy flexible pipe probe (included) to take super-heat or internal temperatures. Or plug in any industry standard type K mini connector thermocouple probe to take those measurements and preserve your investment in thermocouples you already own. Features Contact and non-contact IR thermometer for measuring up close or at a distance, without a ladder Measures temperature from -40°C to 550° C (-40°F to 1022°F) Works with all standard mini-connector type K thermocouples Provides single-point laser sighting Allows easy emissivity adjustment for measuring pipes and other shiny surfaces more accurately Features fabric hook-and-loop fastener pipe probe for superheat, sub-cooling, and other contact and ambient measurements Provides MIN, MAX, and DIF functions to help you quickly identify problems Weighs only 12 ounces/340 grams) and is extremely easy to use Technical Information General Specifications Temperature -40 to 550°C (-40 to 1022°F) Display resolution 0.1°C (0.1°F) of reading D:S (distance to spot size) 12:1 Easy emissivity selector Adjustable with three settings: Low (0.3), medium (0.7). high (0.95) Display accuracy [assumes ambient operating temperature of 23°C (73°F) to 25°C (77°F)] ±1.0% of reading ±1% of reading or ±1°C (±2°F), whichever is greater below 0°C / 32°F, ±1°C (±2°F) ±0.1°/1° Response time 500 mSec (95% of reading) Repeatability ±0.5% of reading or ±1°C (±2°F), whichever is greater Spectral response 8 µm to 14 µm Laser sighting Single point laser Laser shutoff Laser turns off above ambient temperature of 40°C (104°F) Laser power Class 2(II) operation; Output < 1 mW, wavelength 630-670 nm Relative humidity 10% to 90% RH non-condensing, at < 30°C (86°F) Power, battery life 2 AA batteries (alkaline or NiCD) Battery life 12 hours Display hold 7 seconds Backlit display Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery, F/C indicator, and Scan/Hold options Warranty 2 years Operating temperature 0°C to 50°C (32°F to 120°F) Storage temperature -20°C to 65°C (-25°F to 150°F) MAX, MIN, DIF temperatures Yes Thermocouple Type K mini adapter input Yes, compatible with industry standard K type probes with mini-connector. Displays to the thermometer temperature range. Thermocouple Type K fabric hook-and-loop fastener pipe probe Yes, with a temperature range of 0°C to 100°C (32°F to 212°F) and accuracy of ±2.2°C (±4°F) HVAC measurement guide Yes Document Brochure User's Manual
Description The Fluke 1630-2 FC Stakeless Earth Ground Clamp is the kind of high-quality, rugged tool you expect from Fluke. Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments. Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Stay on line—identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system. Features The Fluke 1625-2 is a unique earth ground tester that can perform all four types of earth ground measurement: 3- and 4-Pole Fall-of-Potential (using stakes) 4-Pole Soil Resistivity testing (using stakes) Selective testing (using 1 clamp and stakes) Stakeless testing (using 2 clamps only) Adjustable limits - for quicker testing IP56 rated for outdoor use Rugged carrying case Heavy duty stakes can be hammered into dry, hard soil. And new color-coded wires make setup simple and help eliminate mistakes and speed up setup and tear down time as much as 50% Technical information General Specifications Memory Internal memory storage up to 1500 records accessible via USB port Measuring function Interference voltage and frequency, earthing resistance 3- and 4-pole with/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC Display 4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibility Operation Central rotary switch and function keys Temperature Range Operating temperature -10°C to 50°C (14°F to 122°F) Storage temperature -30°C to 60°C (-22°F to 140°F) Temperature coefficient ±0.1% of reading/°C 28°C Type of protection IP56 for case, IP40 for battery door according to EN60529 Max voltage Warning – socket "clamp" to socket E, ES, S or H U rms = 0 V Sockets E, ES, S or H to each other in any combination, max. U rms = 250 V (pertains to misuse) Safety Protection by double and/or reinforced insulation. Max. 50 V to earth per IEC61010-1. Pollution degree 2 Quality standard Developed, designed and manufactured to comply with DIN ISO 9001 External field influence Complies with DIN 43780 (8/76) Auxiliary power 6 x 1.5 V alkaline (IEC LR6 or type AA) Battery life span With IEC LR6/type AA: typ. 3,000 measurements (R E +R H ≤ 1 kΩ) With IEC LR6/type AA: typ. 6,000 measurements (R E + R H > 10 kΩ) Dimensions (W x H x D) 250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in) Weight ≤ 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case Case material Polyester Measurement of Interference Voltage DC + AC (U ST ) Measuring limits of error: method Full wave rectification Measuring range 1 V to 50 V Display range 0.0 V to 50 V Resolution 0.1 V Frequency range DC/AC 45 Hz to 400 Hz sine Accuracy ±(5% of rdg + 5 digit) Measuring sequence Approx. 4 measurements/s Internal resistance Approx. 1.5 MΩ Max. overload U rms = 250 V Measurement of Interference Frequency (F) Measuring limits of error: method Measurement of oscillation period of the interference voltage Measuring range 6.0 Hz to 400 Hz Display range 16.0 Hz to 299.9 Hz to 999 Hz Resolution 0.1 Hz to 1 Hz Range 1 V to 50 V Accuracy ±(1% of rdg + 2 digit) Earthing Resistance (RE) Measuring method Current and voltage measurement with probe as IEC61557-5 Open circuit voltage 20/48 V, AC Short circuit current 250 mA AC Measuring frequency 94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R 1 Noise rejection 120 dB (16 2/3 , 50 , 60, 400 Hz) Max. overload U rms = 250 V Electrical Measurement Specifications Intrinsic Error or Influence Quantity Reference Conditions or Specified Operating Range Designation Code Requirements or Test in Accordance with the Relevant Parts of IEC 1557 Type of Test Intrinsic error Reference conditions A Part 5, 6.1 R Position Reference position ±90° E1 Part 1, 4.2 R Supply voltage At the limits stated by the manufacturer E2 Part 1, 4.2, 4.3 R Temperature 0°C and 35°C E3 Part 1, 4.2 T Series interference voltage See 4.2 and 4.3 E4 Part 5, 4.2, 4.3 T Resistance of the probes and auxiliary earth electrodes 0 to 100 x R A but ≤ 50 kΩ E5 Part 5, 4.3 T System frequency 99% to 101% of the nominal frequency E7 Part 5, 4.3 T System voltage 85% to 110% of the nominal voltage E8 Part 5, 4.3 T Operating error B = ±(|A| + 1,15 √E 2 1 E 2 2 E 2 3 E 2 4 E 2 5 E 2 6 ) Part 5, 4.3 R B[%] = ± B/fiducial value x 100% A = intrinsic error En = variations R = routine test T = type test Measuring range 0.020 Ω to 300 kΩ Display range 0.001 Ω to 2.999 Ω 3.00 Ω to 29.99 Ω 30.0 Ω to 299.9 Ω 0.300 kΩ to 2.999 kΩ 3.00 kΩ to 29.99 kΩ 30.0 kΩ to 299.9 kΩ Resolution 0.001 Ω 0.01 Ω 0.1 Ω 1 Ω 10 Ω 100 Ω Accuracy ±(2% of rdg + 2 digit) Operating error ±(5% of rdg + 5 digit) Measuring time Typical 8 seconds with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies Additional error because of probe-and auxiliary earth electrode resistance R H (R S + 2000 Ω)/R E x 1.25 x 10 -6 % + 5 digits Measuring error of R H and R S Typ. 10% of R E + R S + R H Max. probe resistance ≤ 1 MΩ Max. auxiliary earth electrode resistance ≤ 1 MΩ Automatic check if error is kept within the limits required by IEC61557-5. If after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than 30% is assumed because of the influencing conditions, the display shows a warning symbol and a notice that RS or RH are too high. Automatic Switchover of Measuring Resolution in Dependence to Auxiliary Earth Electrode Resistance R H RH with U meas = 48 V 250 mA AC Measuring frequency 94, 105, 111, 128 Hz selected manually or automatically (AFC) Measuring range 0.020 Ω to 300 kΩ Display range 0.001 Ω to 2.999 Ω 3.00 Ω to 29.99 Ω 30.0 Ω to 299.9 Ω 300 Ω to 2999 Ω 3.00 kΩ to 29.99 kΩ 30.0 kΩ to 299.9 kΩ Resolution 0.001 Ω 0.01 Ω 0.1 Ω 1 Ω 10 Ω 100 Ω Accuracy ±(2% of rdg + 2 digit) Operating error ±(5% of rdg + 5 digit) Measuring time Typical 6 seconds Max. interference voltage 24 V, with higher voltages measurement will not be started Max overload U rms max. = 250 V Resistance Measurement (R DC) Measuring method Current- voltage measurement as per IEC61557-4 possible Measuring voltage 20 V DC Short circuit current 250 mA DC Formation of measured value With 4-pole measurement wires on H, S, ES can be extended without additional error. Resistances > 1 Ω in wire E can cause additional error of 5m Ω/Ω. Measuring range 0.020 Ω to 300 kΩ Display range 0.001 Ω to 2.999 Ω 3.00 Ω to 29.99 Ω 30.0 Ω to 299.9 Ω 300 Ω to 2999 Ω 3.0 kΩ to 29.99 kΩ 30.0 kΩ to 299.9 kΩ Resolution 0.001 Ω 0.01 Ω 0.1 Ω 1 Ω 10 Ω 100 Ω Accuracy ±(2% of rdg + 2 digit) Operating error ±(5% of rdg + 5 digit) Measuring sequence Approx. 2 measurements/s Measuring time Typical 4 second including reversal of polarity (2-pole or 4-pole) Maximum interference voltage ≤ 3 V AC or DC, with higher voltages measurement will not be started Maximum inductivity 2 Henry Maximum overload U rms = 250 V Compensation of Lead Resistance (R K ) Compensation of lead resistance (R K ) can be switched on in functions R E 3-pole, R E 4-pole (clamp), R AC, and R DC 2-pole Formation of measured value R display = R measured - R compensated 2 2. Value of setpoint entry RK = 0.000 Ω, variable from 0.000 to 29.99 Ω by means of measuring adjustment. Stakeless Ground Loop Measurement (Two Clamp Stakeless) Switch position RA 4-pole (two clamp Stakeless) Resolution 0.001 Ω to 0.1 Ω Measuring range 0.02 Ω to 199.9 Ω Accuracy ±(7% rdg + 3 digit) Operating error ±(10% rdg + 5 digit) Measuring voltage Vm = 48 V AC (primary) Measuring frequency 128 Hz Noise current (IEXT) Max. IEXT = 10 A (AC) (RA 20 Ω) Measuring principle: Stakeless measurement of resistance in closed loops using two current transformers. Automatic range selection. The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified. Document User's Manual Quick Reference Brochure
Description The Fluke 52 II dual-input digital thermometer delivers fast response with laboratory accuracy (0.05% + 0.3°C). You can use the 52 II to measure two contact temperature inputs simultaneously on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or E-type thermocouple temperature sensors. The user friendly-front panel and large, backlit display make it easy to view results from both inputs in multiple ways. And the sleep mode feature preserves battery life to give you a typical thousand hours of operation. Features Dual-input digital thermometer for lab, QA, process calibration, food safety and HVAC Shows any combination of T1, T2, T1-T2, plus MIN, MAX, or AVG on the large backlit dual display Features fast response and laboratory accuracy (0.05% + 0.3°C) Includes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events Easy-to-access battery door that allows replacing the battery without breaking the calibration seal Comes with splash- and dust-resistant case protected by an impact-absorbing holster and a three-year warranty Powered by three, standard AA batteries -30- Features an electronic offset function that compensates for thermocouple errors to maximize overall accuracy Measures J, K, T, and E-type thermocouples Handles temperatures up to 900°C (1600°F) Presents results in °C, °F, or Kelvin (K) Provides a user-friendly front panel that is easy to set up and operate Offers sleep mode to increase battery life; 1000-hour battery life typical Offers optional ToolPak accessory to hang the thermometer from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation Technical Information Specifications Temperature accuracy Above -100°C J, K, T, E, and N-type: ±[0.05% + 0.3°C] 1 R and S-type: ±[0.05% + 0.4°C] 1 Below -100°C J, K, E, and N-types: ±[0.20% + 0.3°C] 1 T-type: ±[0.50% + 0.3°C] Temperature J-type -210°C to 1200°C K-type -200°C to 1372°C T-type -250°C to 400°C E-type -150°C to 1000°C N-type -200°C to 1300°C 1 R and S-type 0°C to 1767°C 1 Temperature scale ITS-90 Applicable standards NIST-175 Display resolution 0.1°C, 0.1 K < 1000 1°C, 1 K ≥ 1000 1. Only the Fluke Models 53 II B and 54 II thermometers are capable of measuring N, R, and S-type thermocouples. Environmental Specifications Operating temperature -10°C to 50°C Storage temperature -40°C to 60°C Humidity (without condensation) 0% to 90%; 0°C to 35°C 0% to 70%; 0°C to 50°C Safety Specifications Overvoltage category CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 Agency approvals CE, CSA, TÜV (pending) Mechanical and General Specifications Size (L x W x D) 173 x 86 x 38 mm Weight 400 g Batteries 3 AA batteries; typical 1000-hour life Document User's Manual
Description “The Fluke 1630 is a MUST HAVE for those who are intent on improving the reliability of their systems and making it impervious to impulse damage. The Fluke 1630 is easy to use, highly accurate and an industry standard”- verified purchaser The 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes. Features Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. AC Leakage Current Measurement: Identify AC leakage without disconnecting your earth ground stake from the grounding system Rugged: Heavy-duty clamp jaw stays in alignment and calibration on tough jobsites Logging measurement: Saves up to 32,760 measurements in memory Technical Information Electrical Specifications Maximum voltage to earth ground 1000 V Battery type AA alkaline IEC/EN LR6 (x4) Battery life More than 15 hours* * In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off Frequency range 40 Hz to 1 kHz Ingress protection IEC/EN 60529: IP30 with jaw closed LCD Digital reading 9999 counts Refresh rate 4 per second Operating temperature -10 °C to + 50 °C Storage temperature -20 °C to + 60 °C Operating humidity Non condensing (28 °C [82.4 °F]) Overload indication OL Data logging capacity Minimum of 32,760 measurements Data logging interval 1 second to 59 minutes and 59 seconds Display reading specification with standard loop resistance Input (Ω) Minimum Maximum 0.474 0.417 0.531 0.5 0.443 0.558 10 9.55 10.45 100 96 104 Safety General IEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1 Measurement IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V Current clamp for leakage current measurements IEC/EN 61557-13: Class 2, ≤30 A/m Resistance to earth IEC/EN 61557-5 Effectiveness of thepProtective measures IEC/EN 61557-16 Electromagnetic compatibility (EMC) International IEC/EN 61326-1: Portable Electromagnetic Environment CISPR 11: Group 1, Class B, IEC/EN 61326-2-2 Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment) USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 Wireless Radio Frequency range 2412 MHz to 2462 MHz Output power <10 mW Radio frequency certification FCC ID:T68-FBLE IC:6627A-FBLE General Specifications Conductor size 40 mm (1.57 in) approximately Dimensions (L x W x H) 283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in) Weight 880g (31 oz) Warranty One year Earth Ground Loop Resistance Range Accuracy 1 ± (% of reading + Ω) 0.025 Ω to 0.249 Ω 1.5% + 0.02 Ω 0.250 Ω to 0.999 Ω 1.5% + 0.05 Ω 1.000 Ω to 9.999 Ω 1.5% + 0.10 Ω 10.00 Ω to 49.99 Ω 1.5% + 0.30 Ω 50.00 Ω to 99.99 Ω 1.5% + 0.50 Ω 100.0 Ω to 199.9 Ω 3.0% + 1.0 Ω 200.0 Ω to 399.9 Ω 5.0% + 5.0 Ω 400 Ω to 599 Ω 10.0% + 10 Ω 600 Ω to 1500 Ω 20.00% 1 Loop resistance with no inductance, conductor centered and perpendicular to jaw Earth ground leakage current mA Autorange 50/60 Hz, True rms, crest factor CF ≤3 Range Resolution Accuracy 1 ± (% of reading + mA) 0.200 mA to 3.999 mA 1 μA 2.0% + 0.05 mA 4.00 mA to 39.99 mA 10 μA 2.0% + 0.03 mA 40.0 mA to 399.9 mA 100 μA 2.0% + 0.3 mA 0.400 A to 3.999 A 1 mA 2.0% + 3 mA 4.00 A to 39.99 A 10 mA 2.0% + 30 mA 1 Applies to signal frequency 40 Hz to 1 kHz with filter set to OFF 40 Hz to 70 Hz with filter se to ON Document User's Manual Quick Reference Brochure
Description The Fluke 771 delivers all the basic functionality you would expect in a milliamp clamp meter. It measures 4-20 mA signals without "breaking the loop," allowing you to measure low level DC current without having to take systems offline for troubleshooting, saving downtime and money. You can also use it to measure output signals from transmitters without breaking the loop when maintaining and troubleshooting process and automation equipment. This saves time and avoids disrupting critical processes so you can avoid expensive downtime. You can also measure 10 to 50 mA signals in older control systems using the 99.9 mA range. Designed to make troubleshooting easier, the Fluke 771 includes a detachable clamp that can be attached to the wire you're testing while you move the meter—connected by the extension cable—to a better viewing position. This is especially helpful for taking readings in tight locations. With the dual backlit display showing both the mA measurement and the percent of a 4 to 20 mA span you can quickly understand what your system is doing, and a built-in LED spotlight lets you illuminate hard to see wire in dark enclosures. You can also capture and display changing measurements using the Hold function making it easier to verify and record measurements. Features Measures 4 to 20 mA signals without breaking the loop Best in class 0.2% accuracy Delivers 0.01 mA resolution and sensitivity Measures mA signals for PLC and control system analog I/O Detachable clamp for measurements in tight locations Technical Information Specifications Diameter of measurable conductor 0.177 in or 4.5 mm max Operating temperature -10 to 50°C Storage temperature -25 to 60°C Operating humidity 28°C) Power, battery life (2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical Warranty Three years for electronics One year for cable and clamp assembly Functional Specifications mA measurement (measured by clamp) Resolution / range 0 to 20.99 mA Accuracy 0.2% + 2 counts Resolution / range 21.0mA to 100.0 mA Accuracy 1% + 5 counts Document Datasheet
Description The Fluke 1550C performs digital insulation testing up to 5 kV, and makes data collection easy through the Fluke Connect™ wireless app. Remote operation lets you spend as little time as possible in potentially hazardous zones. Real-time trending shows a live graph on your phone, rather than a hard-to-read set of changing values. And you can create reports quickly, using pre-designed templates that you can customize with company logos. It’s the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur. And it comes with a three-year warranty and CAT IV 600 V safety rating. Features Quickly configure, start and stop tests on the 1550C remotely, a safe distance away from any operating, energized equipment, using Fluke Connect ® and a smart phone Real time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values Report creation using Fluke Connect desktop saves time and makes test results easier to understand Fluke Connect saves test results to the cloud for analysis and preventive maintenance Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup Guard system eliminates the effect of surface leakage current on high-resistance measurements Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V CAT III 1000 V, CAT IV 600 V safety rating Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall Long battery life gives the user over 750 tests between charges Large digital/analog LCD for easy viewing Capacitance and leakage current measurement Ramp function for breakdown testing Resistance measurements up to 2 TΩ Timer settings up to 99 minutes for timed tests 3-year warranty Technical Information Electrical Specifications The tester's accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add ± .25% per °C, except on the 20% bands add ± 1% per °C. Insulation Resistance Measurement Test voltage (DC) 250 V Range 50 GΩ Accuracy (± reading) Unspecified 5% 20% Unspecified 500 V Range 100 GΩ Accuracy (± reading) Unspecified 5% 20% Unspecified 1000 V Range 200 GΩ Accuracy (± reading) Unspecified 5% 20% Unspecified 2500 V Range 500 GΩ Accuracy (± reading) Unspecified 5% 20% Unspecified 5000 V Range 1 TΩ Accuracy (± reading) Unspecified 5% 20% Unspecified Bar graph range 0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555) Insulation test voltage accuracy -0%, +10% at 1 mA load current Induced AC mains current rejection 2 mA maximum Charging rate for capacitive load 5 seconds per μF Discharge rate for capacitive load 1.5 s/μF Leakage current measurement Range 1 nA to 2 mA Accuracy ± (5% + 2 nA) Capacitance measurement Range 0.01 μF to 15.00 μF Accuracy ± (15% rdg + 0.03 μF) Timer Range 0 to 99 minutes Resolution setting 1 minute Resolution indication 1 second Live circuit warning Warning range 30 V to 660 V AC/DC, 50/60 Hz Voltage accuracy ± (15% + 2 V) Software specifications FlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8. General Specifications Display 75 x 105 mm Power 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 Charger Input (AC) 85 V to 250 V AC 50/60 Hz 20 VA This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only. Dimensions 269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in) Weight 3.7 kg (8.2 lb) Temperature (operating) -20°C to 50°C (-4°F to 122°F) Temperature (storage) -20°C to 65°C (-4°F to 149°F) Humidity 80% to 31°C decreasing linearly to 50% at 50°C Altitude 2000 m Enclosure sealing IP40 Input overload protection 1000 V AC Electromagnetic compatibility EN 61326 Safety compliance IEC 61010-1: Overvoltage category II, Pollution Degree 2. IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III IEC 61557-1, IEC 61557-2 Document User's Manual Quick Reference Brochure
Description The Fluke 289 is the next generation high performance industrial logging multimeter. This Fluke Connect-compatible DMM is designed to solve complex problems in electronics, plant automation, power distribution, and electro-mechanical equipment. Let the 289 be your watchdog for systems or processes while you are off doing other jobs. It provides the ability to log data and graphically review up 10,000 recorded events and logged readings with on-board TrendCapture. Zoom on trend provides a 14x zoom to view and analyze data—without needing a PC. Because the 289 is Fluke Connect-compatible you can set it up with the ir3000 FC wireless connector (sold separately) to communicate with your iOS and Android smart devices through the Fluke Connect mobile app and monitor readings from a remote location. Or you can share readings with your team in an instant anytime, from anywhere with ShareLive™ video call. It can help you solve problems faster and minimize downtime. Features Share results with your team using ShareLive™ video call (requires ir3000 FC wireless connector [sold separately] and no-cost Fluke Connect mobile app). TrendCapture graphically displays logged data session to quickly determine whether anomalies may have occurred. Zoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times. Selectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy. Low Pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment. LoZ Volts. Low impedance voltage function for eliminating ghost voltages. Also recommended when testing for absence or presence of live power. Adjustable recording and auto hold thresholds, specify a percentage change in the readings that begins a new event. Large 50,000 count, 1/4 VGA dot matrix display with white backlight. Measure up to 10 A (20 A for 30 seconds). 100 mF capacitance range. Provides up to a 14x zoom to view and analyze TrendCapture data in depth Includes a selectable AC filter (smoothing mode) to help display a steadier reading when the input signal is changing rapidly or noisy. Offers adjustable recording and auto hold thresholds to specify a percentage change in the readings that begins a new event Features a large 50,000 count, 1/4 VGA dot matrix display with white backlight Stores up to 15,000 recorded events so you can save multiple logging sessions before PC download is necessary Provides two-terminal 50 ohm range with 1 milliohm resolution, 10 mA source current, for measuring and comparing differences in motor winding resistance or contact resistance Includes low pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment. Provides LoZ Volts, a low impedance voltage function for eliminating ghost voltages Recommended when testing for absence or presence of live power Features on-board help screens for measurement functions Includes a real-time clock to automatically time stamp saved readings Offers relative mode to remove test lead resistance from low ohms or capacitance measurements Provides True-RMS AC voltage and current for accurate measurements on non-linear signals Measures up to 10 A (20 A for 30 seconds) Provides up to 100 mF capacitance range Records transients as fast as 250 μs with peak capture Includes premium test leads, alligator clips, and amp jack plugs Offers optional magnetic hanger for easy setup and viewing while freeing your hands for other tasks Works with optional FlukeView forms to enable you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents. Includes a limited lifetime warranty. Technical Information Specifications Function DC volts Range / resolution 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V Basic accuracy 0.025% AC volts Range / resolution 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V Basic accuracy 0.4% (True-RMS) DC current Range / resolution 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A Basic accuracy 0.05% AC current Range / resolution 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A Basic accuracy 0.6% (True-RMS) Temperature (excluding probe) Range / resolution -200.0°C to 1350.0°C (-328.0°F to 2462.0°F) Basic accuracy 1.0% Resistance Range / resolution 50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ Basic accuracy 0.05% Capacitance Range / resolution 1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF Basic accuracy 1.0% Frequency Range / resolution 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz Basic accuracy 0.005% Connectivity Optional infrared connector via Fluke ir3000 FC General Specifications Maximum voltage between any terminal and earth ground 1000 V Battery type 6 AA alkaline batteries, IECLR6 Battery life 100 hours minimum, 200 hours in logging mode Temperature Operating -20°C to 55°C Storage -40°C to 60°C Relative humidity 0 to 90% (0 to 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C) Electromagnetic compatibility EMC EN61326–1 Vibration Random vibration per MIL-PRF-28800F Class 2 Shock 1 meter drop per IEC/EN 61010–1 3rd Edition Size (H x W x L) 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in) Weight 870.9 g (28 oz) Multiple on screen displays Yes True-RMS AC bandwidth 100 kHz dBV/dBm Yes DC mV resolution 1 μV Megohm range Up to 500 MΩ Conductance 50.00 nS Continuity beeper Yes Battery/fuse access Yes/Yes Elapse time clock Yes Time of day clock Yes Min-max-avg Yes Duty cycle Yes Pulse width Yes Isolated optical interface Yes Auto/touch hold Yes Reading memory Yes Log to PC Yes Interval/event logging Yes Logging memory Up to 15,000 readings Wireless connectivity (optional) Yes Document User's Manual Quick Reference
Description SureGrip Fused Test Probe and Test Lead set with built-in replaceable fuses for additional measurement protection. If the probe fuse does blow, these fused test probes will still allow the meter to indicate live voltage, helping to prevent a possible misreading of no voltage present. These modular probes ship with the Fluke TL224 silicone test leads. Rated to CAT III 1000 V, these probes have removable tip guards for reduced probe tip exposure. Features Built in fuses for additional measurement protection, 1000 V, 11 A with 20 kA interrupt rating Fluke fuse part number 803293 Probes allow indication of live voltage even with blown fuse* 2 mm threaded probe tips include removable 4 mm spring contacts and removable insulated caps for probing closely spaced leads TL224 leads are right angle connector on one end and straight connector on the other with reinforced strain reliefs, 1.5 meter silicone – insulated wire resists heat and cold Operating temperature – 20 °C to 50 °C (-5 °F to 120 °F) CAT III 1000 V, CAT IV 600 V, 10 A rating One year warranty *Voltage readings with blown fuse are approximate and vary with the meter impedance. Before and after each measurement, verify presence of blown fuse by checking continuity of the fused test probe. Current mode is non-functional with blown fuse.
Description Take your plan for a proactive maintenance (PM) program and turn it into reality. To get started, you need features that make it easy to set up your image organization and inspection routines. With the TiS75+ you’re well on your way to implementing a successful PM program. Asset Tagging allows you to easily compare asset images over time. Scanning the QR code on each asset creates a timeline of your inspections. Use the time saved (25% on average spent organizing thermal images) to analyze asset images for trends, diagnosing issues and fixing problems before they become failures. This new Fluke thermal camera stays true to our mantra of giving the customer more than they paid for. The Fluke TiS75+ offers features to help you tackle almost anything you’ll face in the field. What's in the box: Thermal imager AC power supply (including universal AC adapters) Two-bay smart battery charger Two rugged lithium ion smart batteries USB cable 4 GB micro SD card Rugged hard carrying case with soft transport bag and adjustable hand strap Available by free download: Fluke Connect™ software and user manual Features 384 x 288 infrared resolution Asset Tagging Touchscreen IR Fusion™ IS3 and AVI video recording Measure up to 550 °C Dew-point calculation IS3 and AVI video recording Data streaming 384 x 288 thermal resolution High temperature range—up to 550 °C Dew-point calculation Technical Information Key Features TiS75+ Infrared resolution 384 x 288 (110,592 pixels) IFOV 1.91 mRad Field of view 42° x 30° Minimum focus distance 0.15 m Focus system Manual focus Wireless connectivity Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi and LAN (where available) Fluke Connect app compatible Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing Fluke Connect Assets optional software Yes*, assign images to assets and create work orders. Easily compare measurement types - whether mechanical, electrical or infrared images - in one location Asset Tagging Scan a QR code to automatically organize and file thermal images with Fluke Connect™ IR-Fusion technology AutoBlend continuous 0 % to 100 %. Adds the context of the visible details to your infrared image Picture-InPicture (PIP) Yes Display 3.5" (8.9 cm landscape) touchscreen 640 x 480 LCD Ergonomic design Designed for one-handed use Thermal sensitivity 40mk Level and span Smooth auto and manual scaling Fast auto-rescale in manual mode Yes Minimum span (in manual mode) 3° °C (4.5 °F) Minimum span (In auto mode) 5°C (9.0 °F) Built-in digital camera (visible light) 640 x 480 Frame rate 9 Hz or 27 Hz models Dew point calculation Yes Data storage and image capture Internal memory ∼500 images External memory ≥4 GB SD card (>1000 images) Image capture, review, save mechanism One-handed image capture, review, and save capability Image file formats Non-radiometric BMP or JPEG or fully-radiometric is2 Memory review Yes Software Fluke Connect software—full analysis and reporting software with access to the Fluke Connect Analyze and store radiometric data on a PC Yes Export file formats with Fluke Connect software is2, BMP, GIF, JPEG, PNG, TIFF Voice annotation Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device. IR-PhotoNotes Yes. Up to 3 extra user-selectable visible light image capture to be included in IS2 file. Text annotations After IS2 capture, user can type in a note using on-screen keyboard. Video recording and formats Standard and radiometric video. Up to 5 minute recording length. avi and is3 Remote control operations No Auto capture (temperature and interval) Yes. User-selectable time interval for capturing IS2 or Jpeg files. Battery Batteries (field-replaceable, rechargeable) Lithium-ion rechargeable battery Battery life ≥3.5 hours continuous without WiFi (Actual life depends on settings and usage) Battery charging time ≤2.5 hours to full charge Battery charging system Ti SBC3B Two-Bay Battery Charger or in-Imager charging. AC operation AC operation with included power supply, universal adapters included Output: 15 VDC, 2 A Power saving User-selectable sleep and power off Temperature measurement Temperature range (not calibrated below -10 °C) -20 °C to 550°C (not calibrated below -10 °C) Accuracy ±2 °C or 2 % (whichever is greater) at 25 °C ambient temperature On-screen emissivity correction Yes, “top ten” material list plus numerical adjustment between 0.01 and 1.00 Color palettes Standard palettes 6 General specifications Color alarms Yes. User-selectable hot and cold point and internal/external range color alarms. Modifies palettization of IR image by limiting which pixels are drawn using palette colors based on the pixel temperature. Infrared spectral band ~8-14μm Operating temperature -10 °C to 50 °C (14 °F to 122 °F) Storage temperature -20 °C to 50 °C (-4 °F to 122 °F) without batteries Relative humidity 10 % to 95 % non-condensing Spot temperature Center spot (unmovable) User-definable spot markers Yes, 5 user-adjustable spot markers for a single pixel each. Position is adjustable. Temperature value for marker shown on screen. User can choose to switch display on/off for each marker. User defined measurement boxes Yes, 5 user-adjustable rectangles. Size and position are adjustable. Rectangle statistics shown on screen: Min, Max, Average temperature. User can choose to switch display on/off for each marker. Hard case Rugged hard carrying case with soft transport bag, including adjustable strap Safety standards IEC 61010-1: Pollution Degree 2 Electromagnetic combability IEC 61326-1: Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A Australian RCM RCM IEC 61326-1 US FCC 47 CFR 15 Subpart C Sections 15.207, 15.209, 15.249 Vibration 10 Hz to 150 Hz, 0.15 mm, IEC 60068-2-6 Shock 30 g, 11 ms, IEC 60068-2-27 Drop Engineered to withstand 2m drop Sized (H x W x L) ∼(26.7 cm x 10.1 cm x 14.5 cm) ∼ (10.5 in x 4.0 in x 5.7 in) Weight (battery included) 0.885 kg (1.95 lbs) Enclosure rating IP54 Warranty Two-years (standard) Recommended calibration cycle Two-years (assumes normal operation and normal aging) Supported languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish RoHS compliant Yes Document User's Manual Quick Reference
Description The TL220, SureGrip™ Industrial Test Lead Set is designed to provide a reliable grip in slippery hands. With interchangeable test lead set for multiple electrical applications. Compatible with all instruments and test probes that accept standard 4 mm shrouded banana connectors. This handy all-in-one kit includes: AC220 SureGrip Alligator Clip Set TP220 SureGrip Insulated Test Probe Set TL224 SureGrip Silicone Test Lead Set Document Datasheet
Description Ideal for electricians, this combo kit is built around the Fluke 87V, the most widely used industrial digital multimeter in the world and includes essential accessories to make you even more productive. This kit offers 15% savings compared with the individual price of all the accessories. Plus you'll be working with the most trusted tools in the world. The Fluke 87V/E2 Industrial Electrician Combo Kit is designed and assembled in the USA. The 87V multimeter is backed by a limited lifetime warranty, so you can rely on your DMM every time you take it out of your tool box. Working on VSDs/VFDs: Take accurate voltage, current and frequency measurements on the output side of the drive at either the drive itself or at the motor terminals. Industrial troubleshooting: Get the resolution and accuracy you need to solve more problems on motor drives, in-plant automation, power distribution, and electromechanical equipment. Checking power quality: Capture glitches and spikes as short as 250 μs. Identify irregular signals. Features Fully insulated 3 mm exposed metal test probes for electricians working in high energy environments C35 Soft Carrying Case holds meter, test leads and other accessories TPAK magnetic hanging strap lets you attach the meter to any ferrous surface, such as cabinets and iron pipes. Advanced measurement functions True-rms ac measurements 0.05% dc accuracy 6,000 counts, 3-3/4 digit resolution, or 20,000 counts, 4-1/2 digit—resolution 10 A ac or dc (with test leads and current jacks) with 0.1 μA resolution Temperature measurements up to 1090 °C with included thermocouple probe Provides 10,000 µF capacitance range for components and motor caps Provides peak capture and Min/Max/Avg recording to capture intermittent as short as 250 µS Easy access door for fast battery changes without breaking the calibration seal Fits into an optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks Presents a large digit display with bright, two-level backlight for easier reading in low light Includes an analog bar graph for fast changing or unstable signals Auto and manual ranging for maximum flexibility Relative mode to calculate and display difference between two readings Holds readings on display for safe viewing after removing probes using Touch Hold technology Technical Information Specifications Voltage DC Maximum Voltage 1000 V Accuracy ±(0.05% + 1) Maximum Resolution 10 µV Voltage AC Maximum Voltage 1000 V Accuracy ±(0.7% + 2) True RMS AC Bandwidth 20 kHz with low pass filter; 3 db @ 1 kHz Maximum Resolution 0.1 mV Current DC Maximum Amps 10 A (20 A for 30 seconds maximum) Amps Accuracy ±(0.2% + 2) Maximum Resolution 0.01 µA Current AC Maximum Amps 10 A (20 A for 30 seconds maximum) Amps Accuracy ±(1.0% + 2) True RMS Maximum Resolution 0.1 µA Resistance Maximum Resistance 50 MΩ Accuracy ±(0.2% + 1) Maximum Resolution 0.1Ω Capacitance Maximum Capacitance 9,999 µF Accuracy ±(1% + 2) Maximum Resolution 0.01 nF Frequency Maximum Frequency 200 kHz Accuracy ±(0.005% + 1) Maximum Resolution 0.01 Hz Duty Cycle Maximum Duty Cycle 99.9% Accuracy ±(0.2% per khz +0.1%) Maximum Resolution 0.1% Temperature Measurement -200.0°C - 1090°C -328.0°F - 1994.0°F excluding probe 80 BK Temperature Probe -40.0°C - 260°C -40.0°F - 500°F, 2.2°C or 2% whichever is greater Conductance Maximum Conductance 60.00 nS Accuracy ±(1.0% + 10) Maximum Resolution 0.01 nS Diode Range 3 V Resolution 1 mV Accuracy ±(2% + 1) Duty Cycle Range Accuracy Within ±(02% per kHz +0.1%) Environmental Specifications Operating Temperature -20°C to +55°C Storage Temperature -40°C to +60°C Humidity (Without Condensation) 0% - 90% (0°C - 35°C) 0% - 70% (35°C - 55°C) Operating Altitude 2000 m Safety Specifications Overvoltage category EN 61010-1 to 1000 V CAT III, 600V CAT IV Agency Approvals UL, CSA, TÜV, VDE listed Mechanical and General Specifications Size 201 x 98 x 52 mm (with holster) Weight 355 g 624 g - with holster Display Digital 6000 counts updates 4/sec. 19,999 counts in high-resolution mode Analog 32 segments, updates 40/sec. Frequency 19,999 counts, updates 3/sec at > 10 Hz Warranty Lifetime Battery Life Alkaline ~400 hours typical, without backlight Shock 1 Meter drop per IEC 61010-1:2001 Vibration Per MIL-PRF-28800 for a Class 2 instrument Document Datasheet
Description The Fluke 62 MAX+ Handheld Infrared Laser Thermo Meter delivers the accuracy you need in an extremely rugged package. Just point, shoot, and read the temperature of many types of equipment. Get accurate readings form transformers, motors, pumps, panels, breakers, compressors, duct, steam lines, valves, and vents. Easy to use The IR thermometer’s small size and versatile features make it extremely easy to use. Plus, the lightweight form factor clips comfortably to your tool belt or belt loop, or easily fits in your toolbox. The 62 MAX+ offers a wide variety of features to take measurements quickly: High and low alarms for rapid detection of measurements outside the limits Displays Min/Max/Avg/Dif The minimum, maximum or average temperature, or the difference between two measurements Easy to read, even in dark areas with large, backlit display Works every place you need to go The 62 MAX+ is rugged enough to take a three-meter drop – good news if you work from a ladder. Dual lasers help you target your measurement; the 12:1 distance to spot ratio helps get the reading you want. With its IP54 rating for dust and water resistance you can rely the Fluke 62 MAX+ to provide extremely accurate temperature measurements, rain or shine, even in dirty and dusty industrial sites. Powered by a single, standard AA battery. Features Extremely rugged – 3-meter drop tested, IP54 for dust and moisture Precise dual-lasers for more accurate, repeatable measurements Provides up to a 12:1 Distance to spot ratio Technical information Specifications Temperature range -30°C to 650°C (-22°F to 1202°F) Accuracy ±1.0°C or ±1.0% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0 Response time (95%) < 500 ms (95% of reading) Spectral response 8 to 14 microns Emissivity 0.10 to 1.00 Optical resolution 12:1 (calculated at 90% energy) Display resolution 0.1°C (0.2°F) Repeatability of readings ±0.5% of reading or <±0.5°C (1°F), whichever is greater Power AA battery Battery life 8 hours with laser and backlight on Physical Specifications Weight 255 g (8.99 oz) Size 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) Operating temperature 0°C to 50°C (32°F to 122°F) Storage temperature -20°C to 60°C (-4°F to 140°F), (without battery) Operating humidity 10% to 90% RH non-condensing at 30°C (86°F) Operating altitude 2000 meters above mean sea level Storage altitude 12,000 meters above mean sea level IP rating IP 54 per IEC 60529 Drop test 3 meters Vibration and shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms Electromagnetic compliance IEC 61326-1: Portable electromagnetic equipment Safety IEC 61010-1: Pollution degree 2 IEC 60825-1: Class 2 Document User's Manual Brochure
Description The Fluke 175 True RMS Digital Multimeter delivers the baseline general purpose features required by professional technicians around the world. You can find problems fast with all the basic troubleshooting measurements such as frequency, capacitance, resistance, continuity, and diode. And Display Hold and Auto Hold will help you capture significant events. All inputs on the 175 are protected to IEN61010-1 CAT IV 600 V/CAT III 1000 V. UL, CSA, TÜV listed and VDE Pending. You can rely on the Fluke 175 for accurate, true-RMS readings through years of reliable service. Features Provides the baseline multimeter features you need for troubleshooting and repairing electrical and electronic systems Delivers accurate true-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements Increases productivity with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-average recording Safety rated CAT III 1000 V, CAT IV 600 V Comes with a lifetime warranty Allows closed-case calibration through front panel Includes ergonomic case with integrated protective holster Technical Information Specifications Voltage DC Accuracy 1 ±(0.15% + 2) Max. resolution 0.1 mV Maximum 1000 V Voltage AC Accuracy 1 ±(1.0% + 3) Max. resolution 0.1 mV Maximum 1000 V Current DC Accuracy 1 ±(1.0% + 3) Max. resolution 0.01 mA Maximum 10 A Current AC Accuracy 1 ±(1.5% + 3) Max. resolution 0.01 mA Maximum 10 A Resistance Accuracy 1 ±(0.9% + 1) Max. resolution 0.1 Ω Maximum 50 MΩ Capacitance Accuracy 1 ±(1.2% + 2) Max. resolution 1 nF Maximum 10,000 µF Frequency Accuracy 1 ±(0.1% + 1) Max. resolution 0.01 Hz Maximum 100 kHz 1. Accuracies are best accuracies for each function Environmental Specifications Operating temperature -10°C to +50°C Storage temperature -30°C to +60°C Humidity (without condensation) 0% – 90% (0°C – 35°C) 0% – 70% (35°C – 50°C) Safety Specifications Overvoltage category EN 61010–1 to 1000 V CAT III EN 61010–1 to 600 V CAT IV Agency approvals UL, CSA, TÜV listed and VDE Pending Mechanical and General Specifications Size 43 x 90 x 185 mm Weight 420 g Warranty Lifetime Battery life Alkaline ~200 hours typical, without backlight Document User's Manual
Description The Fluke 375 FC, part of the Fluke Connect family of wireless test tools, delivers high performance features and ease of use. It features a VFD low-pass filter for accurate motor drive measurements and wireless communications to transmit results to a smartphone via Fluke Connect The 375 FC offers most of the features of the Fluke 376 FC including compatibility with the iFlex flexible current probe but, unlike the 376 FC, it does not include the iFlex® probe in the package. You can measure AC and DC current to 600 A and voltage up to 1000 V with the fixed jaw clamp. Or connect an optional iFlex® flexible current probe to expand your measurement range to 2500 A AC. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access individual wires. Using its Bluetooth connectivity to Apple and Android devices, you can read the 375 FC results a safe distance away on your smartphone, wearing less PPE. You can create and send reports in email right from the field and save results to the cloud. You can also converse with colleagues in real-time with ShareLive™ video calls. With True-RMS AC voltage and current measurements, the 375 enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 375 FC Clamp Meter is the direct replacement for the Fluke 375 Clamp Meter. Features High performance clamp meter that measures very low voltage and high resistance Transmits measurements to your smartphone via Fluke Connect® so you can view them at a safer distance Measures AC and DC current to 600 A, and AC and DC voltage to 1000 V Measures AC current to 2500 A AC with optional iFlex flexible current probe Compatible with optional TPAK magnetic hanging strap Comes with batteries, soft carrying case, and three-year warranty Features CAT III 1000 V, CAT IV 600 V safety rating Measures capacitance to 1000 µF Includes True-RMS voltage and current measurements to accurately measure non-linear signals Measures frequency to 500 Hz and resistance to 60 kΩ with continuity detection Includes Min/Max/Avg and inrush recording to capture variations automatically Offers 500 mV DC measurement range to interface with other accessories Runs on two AA alkaline batteries Technical Information General Specifications AC Current via Jaw Range 600.0 A Resolution 0.1 A Accuracy 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100-500 Hz) Crest Factor (50 Hz/60 Hz) 3 @ 500 A 2.5 @ 600 A Add 2% for C.F. >2 AC Current via Flexible Current Probe Range 2500 A Resolution 0.1 A (≤ 600 A) 1 A (≤ 2500 A) Accuracy 3% ±5 digits (5 – 500 Hz) Crest Factor (50/60Hz) 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 Position Sensitivity i2500-10 Flex i2500-18 Flex A Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm) Error ±0.5 % ±0.5 % B Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm) Error ±1.0 % ±1.0 % C Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm) Error ±2.0 % ±2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 600.0 A Resolution 0.1 A Accuracy 2% ±5 digits AC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1.5% ±5 digits (20 Hz to 500 Hz) DC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1% ±5 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1% ±5 digits Frequency via Jaw Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ±5 digits Trigger level 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥5 A Frequency via Flexible Current Probe Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ±5 digits Trigger level 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A Resistance Range 60 kΩ Resolution 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60 kΩ) Accuracy 1% ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) Accuracy 1% ±4 digits Mechanical Specifications Maximum voltage between any terminal and earth ground 1000 V Batteries 2 AA, NEDA 15A, IEC LR6 Operating temperature -10 °C to +50 °C Storage temperature -40 °C to +60 °C Operating humidity - non-condensing (< 10°C) ≤90% RH (at 10 °C to 30 °C) ≤75% RH (at 30 °C to 40 °C) Operating altitude 3000 m Storage altitude 12,000 m Size (L x W x H) 249 x 85 x 45 mm Weight 395 g Jaw opening 34 mm Flexible current probe diameter 7.5 mm Flexible current probe cable length (head to electronics connector) 1.8 m Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IP rating IEC 60529: IP30, non-operating Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C Document User's Manual Datasheet Brochure