{"title":"Fluke - Testers","description":"","products":[{"product_id":"fluke-insulation-resistance-tester-model-1507","title":"Fluke Insulation Resistance Tester, Model 1507*","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.\u003c\/p\u003e\n\u003cp\u003eTake advantage of the 1507 full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and light weight make it easy to pack and use. Additional features, like the remote probe, save both time and money especially when performing repetitive tests. And its reasonable price and rugged reliability make it an excellent value.\u003c\/p\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePerforms insulation tests from 0.01 MΩ to 10 GΩ\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage from 0.1 V to 600 V and resistance from 0.01 Ω to 20.00 kΩ\u003c\/li\u003e\n\u003cli\u003eProvides lo-ohms earth-bond continuity (200 mA)\u003c\/li\u003e\n\u003cli\u003eSimplifies repetitive or hard-to-reach testing with the remote test probe\u003c\/li\u003e\n\u003cli\u003eSaves battery power with auto power off\u003c\/li\u003e\n\u003cli\u003ePresents results on a large, backlit display\u003c\/li\u003e\n\u003cli\u003eFeatures CAT IV 600 V overvoltage category rating\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, test probes, alligator clips and one-year warranty\u003c\/li\u003e\n\u003cli\u003eAccepts optional Fluke TPAK magnetic hanging system to free your hands for other work\u003c\/li\u003e\n\u003cli\u003eRuns on four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAC\/DC Voltage Measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\nAccuracy Range: 600V\u003cbr\u003eAccuracy Resolution: 0.1V\u003cbr\u003eInput Impedance: \u003cspan data-mce-fragment=\"1\"\u003e3 MΩ (nominal), \u0026lt; 100 pF\u003c\/span\u003e\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003eCommon mode rejection ratio (1 kΩ unbalanced): \u0026gt; 60 dB at DC, 50 or 60 Hz\u003cbr\u003eOverload protection :600 V rms or DC\u003c\/span\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Bond Resistance Measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eRange\/Resolution: 20.00 Ω \/ 0.01 Ω, 200.0 Ω \/ 0.1 Ω, 2000 Ω \/ 1.0 Ω, 20.00 kΩ \/ 0.01 kΩ\u003c\/span\u003e\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003eAccuracy: ±(1.5% + 3)\u003cbr\u003eOverload protection: 2 V rms or DC\u003cbr\u003eOpen circuit test voltage: \u0026gt; 4.0 V, \u0026lt; 8 V\u003cbr\u003eShort circuit current: \u0026gt; 200.0 mA\u003c\/span\u003e\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eMeasurement range: 0.01 MΩ to 10 GΩ\u003cbr\u003eTest voltage: 50 V, 100 V, 250 V, 500 V, 1000 V\u003cbr\u003eTest voltage accuracy: + 20%, - 0%\u003cbr\u003eShort circuit current: 1 mA nominal\u003cbr\u003eAuto discharge: Discharge time \u0026lt; 0.5 second for C = 1 µF or less\u003cbr\u003eLive circuit indicator: Inhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003cbr\u003eMaximum capacitive load: Operable with up to 1 µF load\u003cbr\u003eMeasure accuracy: 50 V ±(3% + 5), 100 V ±(3% + 5), 250 V ±(1.5% + 5), 500 V ±(1.5% + 5), 1000 V ±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/p\u003e\nMaximum voltage applied to any terminal: 600 V AC rms or DC\u003cbr\u003eStorage temperature: -40°C to 60°C (-40°F to 140°F)\u003cbr\u003eOperating temperature: -20°C to 55°C (-4°F to 131°F)\u003cbr\u003eTemperature coefficient: 0.05 x (specified accuracy) per °C for temperatures \u0026lt; 18°C or \u0026gt; 28°C (\u0026lt; 64°F or \u0026gt; 82°F)\u003cbr\u003eRelative humidity: 0% to 95% @ 10°C to 30°C (50°F to 86°F), 0% to 75% @ 30°C to 40°C (86°F to 104°F), 0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003cbr\u003eVibration: Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003cbr\u003eShock: 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)\u003cbr\u003eElectromagnetic compatibility: In an RF field of 3 V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003cbr\u003eSafety: Complies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)\u003cbr\u003eCertifications: CSA per standard CSA\/CAN C22.2 No. 61010.1-04; TUV per standard IEC\/EN 61010-1 2nd Edition\u003cbr\u003eBatteries: Four AA batteries (NEDA 15A or IEC LR6)\u003cbr\u003eSize (H x W x L): 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003cbr\u003eWeight: 550 g (1.2 lb)\u003cbr\u003eIP rating: IP40\u003cbr\u003eAltitude: Operating 2000 m CAT IV 600 V, 3000 m CAT III 600 V - Non-operating (storage) 12,000 m\u003cbr\u003eOver-range capability: 110% of range\u003cbr\u003eIncluded accessories: TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1507_brochure.PDF?v=1659984349\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1507_quick_ref.pdf?v=1659984349\"\u003eQuick Reference\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1507_user_manual.pdf?v=1659984349\"\u003eOwner's manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120483433,"sku":"FLUFLUKE1507","price":1090.92,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/1507-3.jpg?v=1659984688"},{"product_id":"fluke-insulation-tester-multimeter-model-1587-fc","title":"Fluke Insulation Tester Multimeter, Model 1587 FC*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eKeep yourself safe. Find hidden problems faster. Put the paperwork down.\u003cbr\u003eFluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdd diagnostics with Fluke Connect\u003c\/strong\u003e\u003cbr\u003eThe Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIncludes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eK-type thermocouple\u003c\/li\u003e\n\u003cli\u003eSoft case\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety first. Keep yourself out of harm’s way by monitoring your test measurements remotely.\u003c\/li\u003e\n\u003cli\u003eProve your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.\u003c\/li\u003e\n\u003cli\u003eQuickly find problems by saving and comparing measurements over time on a wireless device.\u003c\/li\u003e\n\u003cli\u003ePI\/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster\u003c\/li\u003e\n\u003cli\u003eMemory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time\u003c\/li\u003e\n\u003cli\u003eTemperature compensation to establish accurate baselines and relevant historical comparisons\u003c\/li\u003e\n\u003cli\u003eHistorical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately)\u003c\/li\u003e\n\u003cli\u003eProvides memory storage through Fluke Connect Measurements to eliminate the need to write down results\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eProvides automated temperature compensation to establish accurate baselines\u003c\/li\u003e\n\u003cli\u003eSupports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect® Assets (sold separately)\u003c\/li\u003e\n\u003cli\u003eIncorporates VFD low-pass filter for accurate variable frequency motor drive measurements\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eMeasures ac\/dc voltage, dc millivolts, ac\/dc milliamps, resistance, and continuity\u003c\/li\u003e\n\u003cli\u003eIncludes capacitance, diode test, temperature, min\/max, frequency measurements and insulation test smoothing reading\u003c\/li\u003e\n\u003cli\u003eAutomatically powers off to save battery power\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable height=\"1498\" width=\"538\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd style=\"width: 532.728px;\" colspan=\"3\" data-mce-style=\"width: 532.728px;\"\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 532.728px;\" colspan=\"3\" data-mce-style=\"width: 532.728px;\"\u003eAC voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 532.728px;\" colspan=\"3\" data-mce-style=\"width: 532.728px;\"\u003eRange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" rowspan=\"3\" data-mce-style=\"width: 147.98px;\"\u003e600.0 mV\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" rowspan=\"3\" data-mce-style=\"width: 147.98px;\"\u003e6.000 V\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" rowspan=\"3\" data-mce-style=\"width: 147.98px;\"\u003e60.00 V\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" rowspan=\"3\" data-mce-style=\"width: 147.98px;\"\u003e600.0 V\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(2% + 3)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" rowspan=\"3\" data-mce-style=\"width: 147.98px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(2% + 3)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 532.728px;\" class=\"small\" colspan=\"3\" data-mce-style=\"width: 532.728px;\"\u003e¹ 1 kHz bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd style=\"width: 532.728px;\" colspan=\"3\" data-mce-style=\"width: 532.728px;\"\u003e\u003cstrong\u003eLow-Pass Filter Voltage \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 532.728px;\" colspan=\"3\" data-mce-style=\"width: 532.728px;\"\u003eRange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" rowspan=\"3\" data-mce-style=\"width: 147.98px;\"\u003e600.0 mV\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" rowspan=\"3\" data-mce-style=\"width: 147.98px;\"\u003e6.000 V\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" rowspan=\"3\" data-mce-style=\"width: 147.98px;\"\u003e60.00 V\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" rowspan=\"3\" data-mce-style=\"width: 147.98px;\"\u003e600.0 V\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" rowspan=\"3\" data-mce-style=\"width: 147.98px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 220.263px;\" class=\"nobold\" data-mce-style=\"width: 220.263px;\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd style=\"width: 532.728px;\" colspan=\"3\" data-mce-style=\"width: 532.728px;\"\u003e\u003cstrong\u003eDC Voltage Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" data-mce-style=\"width: 147.98px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e\u003cb\u003eAccuracy ±(% of Rdg + Counts)\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" data-mce-style=\"width: 147.98px;\"\u003e6.000 V dc\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003e0.001 V\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" data-mce-style=\"width: 147.98px;\"\u003e60.00 V dc\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003e0.01 V\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" data-mce-style=\"width: 147.98px;\"\u003e600.0 V dc\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" data-mce-style=\"width: 147.98px;\"\u003e1000 V dc\u003c\/td\u003e\n\u003ctd style=\"width: 220.263px;\" data-mce-style=\"width: 220.263px;\"\u003e1 V\u003c\/td\u003e\n\u003ctd style=\"width: 153.787px;\" data-mce-style=\"width: 153.787px;\"\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" data-mce-style=\"width: 147.98px;\"\u003eInput impedance \u003c\/td\u003e\n\u003ctd style=\"width: 379.399px;\" colspan=\"2\" data-mce-style=\"width: 379.399px;\"\u003e10 MΩ (nominal), \u0026lt;100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" data-mce-style=\"width: 147.98px;\"\u003eNormal mode rejection ratio \u003c\/td\u003e\n\u003ctd style=\"width: 379.399px;\" colspan=\"2\" data-mce-style=\"width: 379.399px;\"\u003e\u0026gt;60 dB @ 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.98px;\" data-mce-style=\"width: 147.98px;\"\u003eCommon mode rejection ratio \u003c\/td\u003e\n\u003ctd style=\"width: 379.399px;\" colspan=\"2\" data-mce-style=\"width: 379.399px;\"\u003e\u0026gt;120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 532.728px;\" class=\"small-font nobold\" colspan=\"3\" data-mce-style=\"width: 532.728px;\"\u003e\n\u003cp\u003eAccuracies apply to ± 100% of range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eDC Millivolts Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy ±(% of Rdg + Counts)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600.0 mVdc\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC and AC Current Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAC 45 Hz to 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 2)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden voltage (Typical)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e60 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 2)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden voltage (Typical)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden voltage (Typical)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden voltage (Typical)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 mA for 2 minutes maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protection for mA input\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.44 mA, 1000 V, IR 10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC conversion\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInputs are ac-coupled and calibrated to the rms value of sine wave input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eConversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e¹ 1 kHz bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eOhms Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy +(% of Rdg+Counts)¹\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6.000 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 kΩ\u003c\/td\u003e\n\u003ctd\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003ctd\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600.0 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 KΩ\u003c\/td\u003e\n\u003ctd\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6.000 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 MΩ\u003c\/td\u003e\n\u003ctd\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50.0 MΩ ²\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V rms or dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit test voltage \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;8.0 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;1.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e¹ Accuracies apply from 0% to 100% of range\u003cbr\u003e² Up to 80% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eDiode Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode test indication\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDisplay voltage drop: 0.6 V at1.0 mA nominal test current:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eContinuity Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity indication\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eContinuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;8.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.0 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;1 m sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eFrequency Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e99.99 Hz \u003c\/td\u003e\n\u003ctd\u003e0.01 Hz \u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e999.9 Hz \u003c\/td\u003e\n\u003ctd\u003e0.1 Hz \u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9.999 kHz \u003c\/td\u003e\n\u003ctd\u003e0.001 kHz \u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e99.99 kHz \u003c\/td\u003e\n\u003ctd\u003e0.01 kHz \u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eFrequency Counter Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e600.0 mV ac \u003c\/td\u003e\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd\u003e100.0 mV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd\u003e150.0 mV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e6.0 V \u003c\/td\u003e\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd\u003e1.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd\u003e1.5 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd\u003e-400.0 mV and 2.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e60.0 V \u003c\/td\u003e\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd\u003e10.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd\u003e36.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd\u003e1.2 V and 4.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e600.0 V \u003c\/td\u003e\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd\u003e100.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd\u003e12.0 V and 40.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e1000.0 V \u003c\/td\u003e\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd\u003e300.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd\u003e12.0 V and 40.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy\u003cbr\u003e² Usable to 100 kHz with full scale input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange \u003c\/td\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 nF \u003c\/td\u003e\n\u003ctd\u003e1 nF\u003c\/td\u003e\n\u003ctd\u003e±(1.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.00 μF \u003c\/td\u003e\n\u003ctd\u003e0.01 μF\u003c\/td\u003e\n\u003ctd\u003e±(1.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100.0 μF \u003c\/td\u003e\n\u003ctd\u003e0.1 μF\u003c\/td\u003e\n\u003ctd\u003e±(1.2% ±90 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e9999 μF \u003c\/td\u003e\n\u003ctd\u003e1 μF\u003c\/td\u003e\n\u003ctd\u003e±(1.2% ±90 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTemperature Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange \u003c\/td\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-40 ° C to 537 ° C \u003c\/td\u003e\n\u003ctd\u003e0.1 °C \u003c\/td\u003e\n\u003ctd\u003e±(1% + 10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-40 ° F to 998 ° F \u003c\/td\u003e\n\u003ctd\u003e0.1 °F \u003c\/td\u003e\n\u003ctd\u003e±(1% + 18 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ to 2 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltages\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50, 100, 250, 500, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+20%, -0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit test current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt;0.5 second for C = 1 μF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive circuit detection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 μF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\"\u003e50 V (0% to +20%)\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0.01 to 6.00 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e6.0 to 50.0 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"12\"\u003e100 V (0% to +20%)\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0.01 to 6.00 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e6.0 to 60.0 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e60 to 100 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\"\u003e250 V (0% to +20%)\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 60.0 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 250 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e60 to 250 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 250 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\"\u003e500 V (0% to +20%)\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 60.0 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 500 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e60 to 500 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 500 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"12\"\u003e1000 V (0% to +20%)\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 60.0 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e60 to 600 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0.6 to 2.0 GΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e100 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(10% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage applied to any terminal and common\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40 °C to 60 °C (-40 °F to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20 °C to 55 °C (-4 °F to 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt;18 °C or \u0026gt;28 °C (\u0026lt;64 °F or \u0026gt;82 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNoncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio frequency communication\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.4 GHz ISM Band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio frequency certification\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFCC: T68-FBLE, IC: 6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eElectromagnetic Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eClass A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eEmissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and\/or test probes are connected.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 60529: IP40 (non-operating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC 61010-1\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC 61010-2-033\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour AA batteries (IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMeter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110% of range except for capacitance which is 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency overload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;107 V Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protection for mA input\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.44A, 1000 V, IR 10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1507_brochure.PDF?v=1659984349\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1587_quick_ref.pdf?v=1659988132\"\u003eQuick Reference\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1587_owner_manual.pdf?v=1659988132\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120548969,"sku":"FLUFLUKE1587FC","price":1512.77,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/Fluke-1587fc-1000x1000.jpg?v=1659988564"},{"product_id":"fluke-non-contact-voltage-tester-model-1ac-ii","title":"Fluke Non-Contact Voltage Tester, Model 1AC-II","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe portable 1AC II non-contact voltage tester from Fluke are easy to use – just touch the tip to a terminal strip, outlet, or supply cord. When the tip glows red and the unit beeps, you know there's voltage present. Electricians, maintenance, service, safety personnel, and homeowners can quickly test for energized circuits in the workplace or at home and even detect miswires of an electrical outlet.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBe aware of voltage easily - the tip glows red and a beeper sounds when voltage is detected\u003c\/li\u003e\n\u003cli\u003eContinuous self-test so you always know it’s working\u003c\/li\u003e\n\u003cli\u003eVoltage detection range for wide application use - 90 V to 1000 V AC or 200 V to 1000 V AC\u003c\/li\u003e\n\u003cli\u003eAudible\/Silent mode for added convenience in quiet environments\u003c\/li\u003e\n\u003cli\u003eOn\/Off button\u003c\/li\u003e\n\u003cli\u003eBatteries included\u003c\/li\u003e\n\u003cli\u003e2 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Principles\u003c\/td\u003e\n\u003ctd\u003eSenses the steady state electrostatic ﬁeld produced by AC voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage sensing ranges\u003c\/td\u003e\n\u003ctd\u003eNominally, 90 V AC to 1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector tip style\u003c\/td\u003e\n\u003ctd\u003eFlat-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eOne high intensity red LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"safety-icon icon-CE\"\u003e‍\u003c\/span\u003e\u003cspan class=\"safety-icon icon-CSA C US\"\u003e‍\u003c\/span\u003e\u003cspan class=\"safety-icon icon-RCM\"\u003e‍\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1: Pollution Degree 2, IEC 61010-2-030: CAT IV 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C (-14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eOperating Humidity Ranges\u003c\/td\u003e\n\u003ctd\u003e0% to 95% (0°C to 30°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0% to 75% (30°C to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0% to 45% (40 to 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleaning\u003c\/td\u003e\n\u003ctd\u003eClean with damp cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e2 AAA alkaline batteries included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eTypical battery life of greater than 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty Period\u003c\/td\u003e\n\u003ctd\u003eTwo years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"2\"\u003eProduct does not respond to random electrostatic discharge.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1acii_users_manual.pdf?v=1660240459\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120745577,"sku":"FLUFLUKE1ACA1II","price":54.73,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/1ac-II-voltage-tester.png?v=1660240475"},{"product_id":"fluke-toolpak™-magnetic-meter-hanger-model-tpak","title":"Fluke ToolPak™ Magnetic Meter Hanger, Model TPAK","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke TPAK ToolPak™ Magnetic Meter Hanger allows you to hang your meter on nails, hooks, and pipes so you can take hands-free measurements. Always demand the best; use the original TPAK Meter hanging kit with its unique rare-earth magnet for superior gripping strength to ensure your tools don’t slide or fall.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHang your meter in a variety of ways for convenient hands-free operation, solve any hanging and positioning problems you may face. Use the hook and loop strap to wrap around a pole or pipe and hang your meter. Use the magnet to throw your meter on a panel door while you work the test leads to take a measurement quickly and safely.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the box:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e9-inch hook and loop strap\u003c\/li\u003e\n\u003cli\u003eTapered hook and loop strap\u003c\/li\u003e\n\u003cli\u003eUniversal hanger clip\u003c\/li\u003e\n\u003cli\u003eHook hanger for non-magnetic surfaces\u003c\/li\u003e\n\u003cli\u003eStrong magnet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStrong, rare-earth magnet hanger strap with Fluke durability \u003c\/li\u003e\n\u003cli\u003eHang with magnet or hook strap for non-magnetic surfaces\u003c\/li\u003e\n\u003cli\u003eSolves any hanging and positioning problem you may face\u003c\/li\u003e\n\u003cli\u003eEasily work hands-free\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/tpak_datasheet.pdf?v=1660244145\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121728617,"sku":"FLUTPAK","price":74.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/tpak-magnetic-hanger.png?v=1660244118"},{"product_id":"fluke-industrial-electrician-combo-kit-model-87v-e2","title":"Fluke Industrial Electrician Combo Kit, Model 87V\/E2*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIdeal for electricians, this combo kit is built around the Fluke 87V, the most widely used industrial digital multimeter in the world and includes essential accessories to make you even more productive. This kit offers 15% savings compared with the individual price of all the accessories. Plus you'll be working with the most trusted tools in the world.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 87V\/E2 Industrial Electrician Combo Kit is designed and assembled in the USA. The 87V multimeter is backed by a limited lifetime warranty, so you can rely on your DMM every time you take it out of your tool box.\u003c\/p\u003e\n\u003cp\u003eWorking on VSDs\/VFDs: Take accurate voltage, current and frequency measurements on the output side of the drive at either the drive itself or at the motor terminals.\u003c\/p\u003e\n\u003cp\u003eIndustrial troubleshooting: Get the resolution and accuracy you need to solve more problems on motor drives, in-plant automation, power distribution, and electromechanical equipment.\u003c\/p\u003e\n\u003cp\u003eChecking power quality: Capture glitches and spikes as short as 250 μs. Identify irregular signals.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFully insulated 3 mm exposed metal test probes for electricians working in high energy environments\u003c\/li\u003e\n\u003cli\u003eC35 Soft Carrying Case holds meter, test leads and other accessories\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap lets you attach the meter to any ferrous surface, such as cabinets and iron pipes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced measurement functions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-rms ac measurements\u003c\/li\u003e\n\u003cli\u003e0.05% dc accuracy\u003c\/li\u003e\n\u003cli\u003e6,000 counts, 3-3\/4 digit resolution, or 20,000 counts, 4-1\/2 digit—resolution\u003c\/li\u003e\n\u003cli\u003e10 A ac or dc (with test leads and current jacks) with 0.1 μA resolution\u003c\/li\u003e\n\u003cli\u003eTemperature measurements up to 1090 °C with included thermocouple probe\u003c\/li\u003e\n\u003cli\u003eProvides 10,000 µF capacitance range for components and motor caps\u003c\/li\u003e\n\u003cli\u003eProvides peak capture and Min\/Max\/Avg recording to capture intermittent as short as 250 µS\u003c\/li\u003e\n\u003cli\u003eEasy access door for fast battery changes without breaking the calibration seal\u003c\/li\u003e\n\u003cli\u003eFits into an optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks\u003c\/li\u003e\n\u003cli\u003ePresents a large digit display with bright, two-level backlight for easier reading in low light\u003c\/li\u003e\n\u003cli\u003eIncludes an analog bar graph for fast changing or unstable signals\u003c\/li\u003e\n\u003cli\u003eAuto and manual ranging for maximum flexibility\u003c\/li\u003e\n\u003cli\u003eRelative mode to calculate and display difference between two readings\u003c\/li\u003e\n\u003cli\u003eHolds readings on display for safe viewing after removing probes using Touch Hold technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.05% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e10 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eVoltage AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.7% + 2) True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Bandwidth\u003c\/td\u003e\n\u003ctd\u003e20 kHz with low pass filter; 3 db @ 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Amps\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A (20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Amps\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A (20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 2) True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Resistance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Capacitance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e9,999 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Frequency\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.005% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Duty Cycle\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% per khz +0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-200.0°C - 1090°C\u003cbr\u003e-328.0°F - 1994.0°F\u003cbr\u003eexcluding probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80 BK Temperature Probe\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40.0°C - 260°C\u003cbr\u003e-40.0°F - 500°F, 2.2°C or 2% whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eConductance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Conductance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e60.00 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDiode\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle Range\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±(02% per kHz +0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (Without Condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% - 90% (0°C - 35°C)\u003cbr\u003e0% - 70% (35°C - 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61010-1 to 1000 V CAT III, 600V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUL, CSA, TÜV, VDE listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e201 x 98 x 52 mm (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e355 g\u003cbr\u003e624 g - with holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eDigital\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 counts updates 4\/sec.\u003cbr\u003e19,999 counts in high-resolution mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog\u003c\/td\u003e\n\u003ctd\u003e32 segments, updates 40\/sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e19,999 counts, updates 3\/sec at \u0026gt; 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAlkaline\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e~400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 Meter drop per IEC 61010-1:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePer MIL-PRF-28800 for a Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/875e2_datasheet.pdf?v=1660236834\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122121833,"sku":"FLUFLUKE875E2KIT","price":1114.39,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/87v-e2-box-contents_0.png?v=1660236877"},{"product_id":"fluke-suregrip™-industrial-test-lead-set-model-tl220","title":"Fluke SureGrip™ Industrial Test Lead Set, Model TL220","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe TL220, SureGrip™ Industrial Test Lead Set is designed to provide a reliable grip in slippery hands. With interchangeable test lead set for multiple electrical applications. Compatible with all instruments and test probes that accept standard 4 mm shrouded banana connectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis handy all-in-one kit includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC220 SureGrip\u003c\/li\u003e\n\u003cli\u003eAlligator Clip Set\u003c\/li\u003e\n\u003cli\u003eTP220 SureGrip\u003c\/li\u003e\n\u003cli\u003eInsulated Test Probe Set\u003c\/li\u003e\n\u003cli\u003eTL224 SureGrip Silicone Test Lead Set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/tl220.pdf?v=1660241906\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122154601,"sku":"FLUTL220","price":165.19,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F-tl220_02a_c_W.png?v=1660241928"},{"product_id":"fluke-twistguard™-test-leads-model-tl175","title":"Fluke TwistGuard™ Test Leads, Model TL175","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eTwist. Test. Stay Safe.\u003c\/p\u003e\n\u003cp\u003eThe Fluke TL175 TwistGuard™ Test Leads offer adjustable length test tips for use in different measurement environments. By simply twisting the test lead the user can change the exposed probe tip length from 19 mm to 4 mm (0.75 in to 0.16 in).\u003c\/p\u003e\n\u003cp\u003e“\u003cem\u003eThey work well, are very durable, and add a whole new level to safety…along with the ability to twist them to expose the entire probe for more traditional feel while testing\u003c\/em\u003e”- S.C., verified customer\u003c\/p\u003e\n\u003cp\u003eThe adjustable tip shroud meets new electrical safety requirements to reduce tip exposure while providing the versatility needed for most measurements. The correct category rating for the tip exposure being used is always visible on the test leads. This makes the TL175 test leads suitable for use in many environments:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCAT II 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWearGuard™ lead wire wear indicator makes it easier to see insulation wear and tear. If the inner, white insulation layer shows through the outer, black layer, damage is indicated, and the leads must be replaced. The silicone insulation withstands high temperatures and remains flexible in cold temperatures. While the universal input plugs are compatible with all instruments that accept standard 4 mm shrouded banana plugs.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePatented TwistGuard™ reduces tip exposure\u003c\/li\u003e\n\u003cli\u003eNew WearGuard™ silicone leads indicate when to replace leads\u003c\/li\u003e\n\u003cli\u003eHeavy-duty strain relief tested to 30,000+ bends without failure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/tl175_datasheet.pdf?v=1660327224\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/tl175_instruction_sheet.pdf?v=1660327224\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122220137,"sku":"FLUTL175","price":67.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/fluke-tl175-2.png?v=1660327270"},{"product_id":"fluke-fused-test-probe-set-with-test-leads-model-ftpl-1","title":"Fluke Fused Test Probe Set with Test Leads, Model FTPL-1*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eSureGrip Fused Test Probe and Test Lead set with built-in replaceable fuses for additional measurement protection.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the probe fuse does blow, these fused test probes will still allow the meter to indicate live voltage, helping to prevent a possible misreading of no voltage present. These modular probes ship with the Fluke TL224 silicone test leads. Rated to CAT III 1000 V, these probes have removable tip guards for reduced probe tip exposure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt in fuses for additional measurement protection, 1000 V, 11 A with 20 kA interrupt rating\u003c\/li\u003e\n\u003cli\u003eFluke fuse part number 803293\u003c\/li\u003e\n\u003cli\u003eProbes allow indication of live voltage even with blown fuse*\u003c\/li\u003e\n\u003cli\u003e2 mm threaded probe tips include removable 4 mm spring contacts and removable insulated caps for probing closely spaced leads\u003c\/li\u003e\n\u003cli\u003eTL224 leads are right angle connector on one end and straight connector on the other with reinforced strain reliefs, 1.5 meter silicone – insulated wire resists heat and cold\u003c\/li\u003e\n\u003cli\u003eOperating temperature – 20 °C to 50 °C (-5 °F to 120 °F)\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V, 10 A rating\u003c\/li\u003e\n\u003cli\u003eOne year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*Voltage readings with blown fuse are approximate and vary with the meter impedance. Before and after each measurement, verify presence of blown fuse by checking continuity of the fused test probe. Current mode is non-functional with blown fuse.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122383977,"sku":"FLUFTPL1","price":267.39,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-ftpl-1_01a_h-1500x1000.png?v=1660159299"},{"product_id":"fluke-5-kv-insulation-tester-model-1550c","title":"Fluke 5 kV Insulation Tester, Model 1550C*","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 1550C performs digital insulation testing up to 5 kV, and makes data collection easy through the Fluke Connect™ wireless app. Remote operation lets you spend as little time as possible in potentially hazardous zones. Real-time trending shows a live graph on your phone, rather than a hard-to-read set of changing values. And you can create reports quickly, using pre-designed templates that you can customize with company logos. It’s the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur. And it comes with a three-year warranty and CAT IV 600 V safety rating.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQuickly configure, start and stop tests on the 1550C remotely, a safe distance away from any operating, energized equipment, using\u003cspan\u003e \u003c\/span\u003eFluke Connect\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eand a smart phone\u003c\/li\u003e\n\u003cli\u003eReal time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values\u003c\/li\u003e\n\u003cli\u003eReport creation using\u003cspan\u003e \u003c\/span\u003eFluke Connect desktop\u003cspan\u003e \u003c\/span\u003esaves time and makes test results easier to understand\u003c\/li\u003e\n\u003cli\u003eFluke Connect\u003cspan\u003e \u003c\/span\u003esaves test results to the cloud for analysis and preventive maintenance\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"nobold\"\u003eThe tester's accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add ± .25% per °C, except on the 20% bands add ± 1% per °C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTest voltage (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ,\u003cbr\u003e250 kΩ to 5 GΩ\u003cbr\u003e5 GΩ to 50 GΩ\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cbr\u003e500 kΩ to 10 GΩ\u003cbr\u003e10 GΩ to 100 GΩ\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cbr\u003e1 MΩ to 20 GΩ\u003cbr\u003e20 GΩ to 200 GΩ\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cbr\u003e50 GΩ to 500 GΩ\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cbr\u003e5 MΩ to 100 GΩ\u003cbr\u003e100 GΩ to 1 TΩ\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar graph range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation test voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-0%, +10% at 1 mA load current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInduced AC mains current rejection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging rate for capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 seconds per μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge rate for capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 s\/μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLeakage current measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e± (5% + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCapacitance measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 μF to 15.00 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e± (15% rdg + 0.03 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTimer\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 99 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution setting\u003c\/td\u003e\n\u003ctd\u003e1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution indication\u003c\/td\u003e\n\u003ctd\u003e1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLive circuit warning\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eWarning range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e30 V to 660 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage accuracy\u003c\/td\u003e\n\u003ctd\u003e± (15% + 2 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware specifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e75 x 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12 V lead-acid rechargeable battery, Yuasa NP2.8-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharger Input (AC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e85 V to 250 V AC 50\/60 Hz 20 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"nobold\"\u003eThis Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.7 kg (8.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature (operating)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 50°C (-4°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature (storage)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 65°C (-4°F to 149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e80% to 31°C decreasing linearly to 50% at 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure sealing\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput overload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Overvoltage category II, Pollution Degree 2.\u003cbr\u003eIEC 61010-2-030: Measurement 600V CAT IV \/ 1000V CAT III\u003cbr\u003eIEC 61557-1, IEC 61557-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1550c_user_manual.pdf?v=1660067989\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1550c_quick_ref.pdf?v=1660067988\"\u003eQuick Reference\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1550c_brochure.PDF?v=1660068016\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122547817,"sku":"FLUFLUKE1550C","price":7685.48,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F-1550c__ir3000fc_white_0.png?v=1660068468"},{"product_id":"fluke-suregrip™-master-accessory-set-model-tlk-225","title":"Fluke SureGrip™ Master Accessory Set, Model TLK-225*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eTest leads are an integral part of the complete measurement system. Worn out test leads can cause inaccurate readings and pose serious shock or electrocution hazard. The Fluke TLK-225 SureGrip™ Master Accessory Set with 13 items is the perfect replacement kit that provides flexibility and comfort with all SureGrip™ leads and probes in a convenient six pocket, roll up pouch.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSet includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTL224 Test Lead Set\u003c\/li\u003e\n\u003cli\u003eTP175 TwistGuard™ Test Probes\u003c\/li\u003e\n\u003cli\u003eAC285 SureGrip™ Alligator Clips\u003c\/li\u003e\n\u003cli\u003eAC220 SureGrip™ Alligator Clips\u003c\/li\u003e\n\u003cli\u003eAC280 SureGrip™ Hook Clips\u003c\/li\u003e\n\u003cli\u003eAC283 SureGrip™ Pincer Clips\u003c\/li\u003e\n\u003cli\u003eA convenient six-pocket roll up pouch\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/tlk225_datasheet.pdf?v=1660243543\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213123072105,"sku":"FLUTLK225","price":342.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-tlk225_03c_h-1500x1000.png?v=1660243567"},{"product_id":"fluke-hard-point™-test-lead-set-model-tl75","title":"Fluke Hard Point™ Test Lead Set, Model TL75","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke TL75 Hard Point™ Test Leads are a set of comfort grip, PVC-insulated probes. TL75s offer the convenience of a test lead and probe together in one unit with a variety of connections. This set of test leads are recommended for all general-purpose measurements and are compatible with a wide range of Fluke meters and tools.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke TL75 Hard Point™ Test Lead Set is CAT II 1000 V, 10 A rated. When the protective caps are placed on the leads, the ratings jump up to CAT IV 600 V, CAT III 1000 V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTest lead and probe in one unit\u003c\/li\u003e\n\u003cli\u003e48 inches (1.22 meter) long\u003c\/li\u003e\n\u003cli\u003eCAT II 1000 V, 10 A rated\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V rated with protective cap\u003c\/li\u003e\n\u003cli\u003eCSA Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213123104873,"sku":"FLUTL75","price":44.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/fluke-tl75-1.png?v=1660235850"},{"product_id":"fluke-geo-earth-ground-tester-kit-model-1625-2-kit","title":"Fluke GEO Earth Ground Tester Kit, Model 1625-2 Kit*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 1630-2 FC Stakeless Earth Ground Clamp is the kind of high-quality, rugged tool you expect from Fluke. Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments. Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Stay on line—identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1625-2 is a unique earth ground tester that can perform all four types of earth ground measurement:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3- and 4-Pole Fall-of-Potential (using stakes)\u003c\/li\u003e\n\u003cli\u003e4-Pole Soil Resistivity testing (using stakes)\u003c\/li\u003e\n\u003cli\u003eSelective testing (using 1 clamp and stakes)\u003c\/li\u003e\n\u003cli\u003eStakeless testing (using 2 clamps only) Adjustable limits - for quicker testing\u003c\/li\u003e\n\u003cli\u003eIP56 rated for outdoor use\u003c\/li\u003e\n\u003cli\u003eRugged carrying case\u003c\/li\u003e\n\u003cli\u003eHeavy duty stakes can be hammered into dry, hard soil.\u003c\/li\u003e\n\u003cli\u003eAnd new color-coded wires make setup simple and help eliminate mistakes and speed up setup and tear down time as much as 50%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInternal memory storage up to 1500 records accessible via USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring function\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInterference voltage and frequency, earthing resistance 3- and 4-pole with\/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCentral rotary switch and function keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eTemperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-30°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±0.1% of reading\/°C \u0026lt; 18°C \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of protection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIP56 for case, IP40 for battery door according to EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMax voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWarning – socket \"clamp\" to socket E, ES, S or H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eSockets E, ES, S or H to each other in any combination, max. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (pertains to misuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eProtection by double and\/or reinforced insulation. Max. 50 V to earth per IEC61010-1. Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality standard\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDeveloped, designed and manufactured to comply with DIN ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal field influence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eComplies with DIN 43780 (8\/76)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary power\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6 x 1.5 V alkaline (IEC LR6 or type AA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life span\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith IEC LR6\/type AA: typ. 3,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e+R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e≤ 1 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eWith IEC LR6\/type AA: typ. 6,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 10 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase material\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ePolyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMeasurement of Interference Voltage DC + AC (U\u003csub\u003eST\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eFull wave rectification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.0 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDC\/AC 45 Hz to 400 Hz sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 4 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 1.5 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMeasurement of Interference Frequency (F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMeasurement of oscillation period of the interference voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6.0 Hz to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e16.0 Hz to 299.9 Hz to 999 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Hz to 1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(1% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eEarthing Resistance (RE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCurrent and voltage measurement with probe as IEC61557-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e20\/48 V, AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise rejection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e120 dB (16 2\/3 , 50 , 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eElectrical Measurement Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd\u003eIntrinsic Error or Influence Quantity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eReference Conditions or Specified Operating Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eDesignation Code\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRequirements or Test in Accordance with the Relevant Parts of IEC 1557\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eType of Test\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd\u003eReference conditions\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003ePart 5, 6.1\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition\u003c\/td\u003e\n\u003ctd\u003eReference position ±90°\u003c\/td\u003e\n\u003ctd\u003eE1\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003eAt the limits stated by the manufacturer\u003c\/td\u003e\n\u003ctd\u003eE2\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2, 4.3\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0°C and 35°C\u003c\/td\u003e\n\u003ctd\u003eE3\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries interference voltage\u003c\/td\u003e\n\u003ctd\u003eSee 4.2 and 4.3\u003c\/td\u003e\n\u003ctd\u003eE4\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.2, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance of the probes and auxiliary earth electrodes\u003c\/td\u003e\n\u003ctd\u003e0 to 100 x R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ebut ≤ 50 kΩ\u003c\/td\u003e\n\u003ctd\u003eE5\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem frequency\u003c\/td\u003e\n\u003ctd\u003e99% to 101% of the nominal frequency\u003c\/td\u003e\n\u003ctd\u003eE7\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem voltage\u003c\/td\u003e\n\u003ctd\u003e85% to 110% of the nominal voltage\u003c\/td\u003e\n\u003ctd\u003eE8\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eB = ±(|A| + 1,15 √E\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e1\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e4\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e5\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e6\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold small-font\"\u003eB[%] = ± B\/fiducial value x 100%\u003cbr\u003e\u003cbr\u003eA = intrinsic error\u003cbr\u003eEn = variations\u003cbr\u003eR = routine test\u003cbr\u003eT = type test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eTypical 8 seconds with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error because of probe-and auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eTyp. 10% of R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. probe resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" class=\"nobold\"\u003eAutomatic check if error is kept within the limits required by IEC61557-5.\u003cbr\u003eIf after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than 30% is assumed because of the influencing conditions, the display shows a warning symbol and a notice that RS or RH are too high.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAutomatic Switchover of Measuring Resolution in Dependence to Auxiliary Earth Electrode Resistance R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 48 V\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 300 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e\u0026lt; 6 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e\u0026lt; 60 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e\u0026lt; 600 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 20 V\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e\u0026lt; 2.5 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e\u0026lt; 25 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e\u0026lt; 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e10 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e100 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eSelective Measurement of the Earthing Resistance (R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eClamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eCurrent and voltage measurement with probe as per EN61557-5 and current measurement in the individual branch with additional current transformer (patent applied for).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e20\/48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC), 55 Hz (R\u003csup\u003e1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise rejection\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e120 dB (162\/3, 50, 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eMax. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (measurement will not be started)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e±(7% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e±(10% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error because of probe- and auxiliary earth typ. electrode resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eTyp. of 10% of R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eTyp. 8 sec. with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMinimal current in single branch to be measured\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e0.5 mA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.1 mA\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith transformer (200:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. interference current through transformer\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e3 A\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" class=\"nobold small-font\"\u003e1. With recommended current clamps\/transformers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance Measurement (R~)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eCurrent and voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e20 V AC, square pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e\u0026gt; 250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e24 V, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003emax. = 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance Measurement (R DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eCurrent- voltage measurement as per IEC61557-4 possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e20 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e250 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eWith 4-pole measurement wires on H, S, ES can be extended without additional error.\u003cbr\u003eResistances \u0026gt; 1 Ω in wire E can cause additional error of 5m Ω\/Ω.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e3.0 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 2 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 4 second including reversal of polarity (2-pole or 4-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 3 V AC or DC, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum inductivity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2 Henry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eCompensation of Lead Resistance (R\u003csub\u003eK\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" class=\"nobold\"\u003eCompensation of lead resistance (R\u003csub\u003eK\u003c\/sub\u003e) can be switched on in functions R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole, R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole (clamp), R AC, and R DC 2-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eR\u003csub\u003edisplay\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= R\u003csub\u003emeasured\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e- R\u003csub\u003ecompensated\u003c\/sub\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" class=\"nobold small-font\"\u003e2. Value of setpoint entry RK = 0.000 Ω, variable from 0.000 to 29.99 Ω by means of measuring adjustment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eStakeless Ground Loop Measurement (Two Clamp Stakeless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eRA 4-pole (two clamp Stakeless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.02 Ω to 199.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(7% rdg + 3 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(10% rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eVm = 48 V AC (primary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNoise current (IEXT)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMax. IEXT = 10 A (AC) (RA \u0026lt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"nobold\"\u003eMax. IEXT = 2 A (AC) (RA \u0026gt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" class=\"nobold\"\u003eMeasuring principle: Stakeless measurement of resistance in closed loops using two current transformers.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eThe information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1625_USERMANUAL.pdf?v=1660159600\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1625_QUICK_REF.pdf?v=1660159600\"\u003eQuick Reference\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1625_BROCHURE.PDF?v=1660159600\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213123498089,"sku":"FLUFLUKE16252KIT","price":7499.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/1ac-II-non-contact-voltage-testing_1.png?v=1660159841"},{"product_id":"fluke-voltage-detector-pen-non-contact-voltage-tester-model-2ac","title":"Fluke Voltage Detector Pen, Non-Contact Voltage Tester, Model 2AC","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 2AC is the latest addition to the VoltAlert™ AC non-contact voltage tester family. It is designed to be pocket-sized and easy to use. The tip of the pocket-sized tester will glow red when within close proximity of an outlet, terminal strip, or power cord where voltage is present. The 2 AC is always on, with a battery check function to make sure the tester is working properly. *\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e* Use of Battery Check function is optional and for convenience only, it is not intended as a substitute for checking the unit on a known live source before and after use.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact voltage detection from 90 to 1000 V AC\u003c\/li\u003e\n\u003cli\u003eInnovative 'Battery Check' ensures battery is in good condition*\u003c\/li\u003e\n\u003cli\u003eIntegrated clip design, optimized for pocket storage\u003c\/li\u003e\n\u003cli\u003eCAT IV 1000 V overvoltage rated product for best in class user protection\u003c\/li\u003e\n\u003cli\u003eSuitable for a wide range of residential, commercial and industrial needs\u003c\/li\u003e\n\u003cli\u003eFluke ruggedness and reliability with a two-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Principles\u003c\/td\u003e\n\u003ctd\u003eSenses the steady state electrostatic ﬁeld produced by AC voltage through insulation without requiring contact to the bare conductor. A red glow at the tip indicates the presence of voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets IEC 61010-1:2001, UL 61010-1 (2nd ed.), CAN\/CSA-C22.2 No. 61010-1-04, and ISA-82.02.01 Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets IEC 61326-1:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating\u003c\/td\u003e\n\u003ctd\u003e90 V AC to 1000 V AC, CAT IV 1000 V rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature (Operating and Storage)\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C (-14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eOperating Humidity Ranges\u003c\/td\u003e\n\u003ctd\u003e0% to 95% (0°C to 30°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0% to 75% (30°C to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0% to 45% (40°C to 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e2000 m (CAT IV 1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleaning\u003c\/td\u003e\n\u003ctd\u003eClean with damp cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eTypical battery life of greater than one year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty Period\u003c\/td\u003e\n\u003ctd\u003eTwo years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/2ac_datasheet.pdf?v=1660327015\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/2ac_instruction_sheet.pdf?v=1660327015\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213123629161,"sku":"FLUFLK2AC901000V","price":71.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F-2ac_05a_w.png?v=1660327055"},{"product_id":"fluke-15b-digital-multimeter-model-fluke-15b-esp","title":"Fluke 15B+ Digital Multimeter, Model FLUKE-15B+ ESP*","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 302+ is a compact, easy-to-use digital clamp meter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where True-RMS accuracy isn’t needed, the Fluke 302+ delivers reliable measurements time after time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 302+ Additional Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Fluke 302+ CAT III Digital Clamp Meter is more compact, making the use of clamp-type ammeter more flexible and simpler\u003c\/li\u003e\n\u003cli\u003eMeasure AC current up to 400A\u003c\/li\u003e\n\u003cli\u003e30 mm large jaw\u003c\/li\u003e\n\u003cli\u003eHigh accuracy of 1.8%\u003c\/li\u003e\n\u003cli\u003eBacklit display\u003c\/li\u003e\n\u003cli\u003eTwo-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 302+ Comes with Fluke TL75 Hard Point™ Test Lead Set\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne pair (red, black) of comfort grip probes\u003c\/li\u003e\n\u003cli\u003e48 inches (1.22 meter) PVC insulated test leads with right-angle shrouded banana plugs\u003c\/li\u003e\n\u003cli\u003eRecommended for general purpose measurements\u003c\/li\u003e\n\u003cli\u003eCAT II 1000 V, 10 A rating\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V only with protective cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 302+ Safety Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeets CAT IV 300V\/CAT ||| 600V safety rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC current measurements up to 400 A, handling your everyday electrical maintenance needs\u003c\/li\u003e\n\u003cli\u003eComes with the TL75 Hard Point™ Test Lead Set offering the convenience of a test lead and probe in one unit with a variety of connections\u003c\/li\u003e\n\u003cli\u003eRugged, easy-to-use digital clamp meter with CAT IV 300 V\/CAT III 600 V safety rating\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTechnical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" width=\"25%\"\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.8% ±5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400\/600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ±5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400\/600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ±5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDC mV range\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% ±5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤ 70 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBacklight display\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eH x W x D (mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e208 x 58.5 x 28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw size\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0 ~ 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eScreen refresh rate\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 2 times \/ sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTest leads\u003c\/td\u003e\n\u003ctd\u003eTL75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e2 AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/flk-240133-en-global-15B-plus-17B-plus-ds-w.pdf?v=1721326626\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/usermanual.pdf?v=1721326901\"\u003eUser Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/calibrationmanual.pdf?v=1721326902\"\u003eCalibration Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/safety_information.pdf?v=1721326900\"\u003eSafety Information\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/quick_ref.pdf?v=1721326902\"\u003eQuick Ref\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41733572067433,"sku":"FLUFLUKE15B+ESP","price":154.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/F_15b_2B_01a_h_1500x1000_1.png?v=1721327002"},{"product_id":"fluke-1555-fc-10-kv-insulation-tester","title":"Fluke 1555 FC 10 kV Insulation Tester","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cp\u003eThe Fluke 1555 insulation resistance tester offers digital insulation testing up to 10 kV, making it ideal for testing high voltage equipment including switchgear, motors, generators and cables.\u003c\/p\u003e\n\u003cp\u003eData collection is easy using the Fluke Connect® wireless app. Remote operation lets you spend as little time as possible in potentially hazardous zones. Real-time trending shows a live graph on your phone, rather than a hard-to-read set of changing values. And you can create reports quickly, using pre-designed templates that you can customize with company logos. The 1555 insulation tester can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":54424894865780,"sku":"FLUFLUKE1555","price":10337.59,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/Fluke1555.webp?v=1776649901"}],"url":"https:\/\/orka.ca\/collections\/fluke-testers.oembed","provider":"Orka","version":"1.0","type":"link"}