{"title":"Fluke Temperature Measurement Tools","description":"","products":[{"product_id":"fluke-mini-infrared-thermometer-model-62-max","title":"Fluke Mini Infrared Temperature Guage, Model 62-MAX","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 62 MAX Infrared temperature guage delivers many of the features of the Fluke 62 MAX+, but features a single laser and 10:1 distance to spot ratio. You can use the Fluke 62 MAX to perform non-contact temperature measurements on transformers, motors, pumps, panels, breakers, compressors, duct, steam lines, valves, and vents. It is small in size and extremely easy to use. The single laser helps you pinpoint the target for more accurate readings and makes it easier to measure temperatures in hard to reach areas. With its IP54 rating for dust and water resistance you can rely the Fluke 62 MAX to deliver accurate, repeatable temperature measurements, rain or shine, in even the dirtiest and dustiest industrial sites. And it’s rugged enough to take a 3-meter drop so no worries even if you work from a ladder.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHighly accurate infrared thermometer for measuring temperatures from -30°C to 500°C (-22°F to 932°F) accurate to +1.5°C or +1.5% of reading (whichever is greater)\u003c\/li\u003e\n\u003cli\u003eProvides a 10:1 Distance to spot ratio\u003c\/li\u003e\n\u003cli\u003eOffers single laser targeting for accurate and repeatable measurements\u003c\/li\u003e\n\u003cli\u003eFeatures IP54 rating against dust and moisture\u003c\/li\u003e\n\u003cli\u003eHigh and low alarms for rapid detection of temperatures outside the limits\u003c\/li\u003e\n\u003cli\u003ePowered by a single, standard AA battery.\u003c\/li\u003e\n\u003cli\u003eComes with a three-year warranty -30-\u003c\/li\u003e\n\u003cli\u003eWithstands a 3 m (9.8 ft.) drop\u003c\/li\u003e\n\u003cli\u003eOffers small, lightweight form factor to clip comfortably to your tool belt or belt loop, or easily fit in your tool box\u003c\/li\u003e\n\u003cli\u003eFeatures a large, backlit display to make data easier to read, even in dark areas.\u003c\/li\u003e\n\u003cli\u003eDisplays Min\/Max\/Avg\/Dif: the minimum, maximum or average temperature, or the difference between two measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-30°C to 500°C (-22°F to 932°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±1.5°C or ±1.5% of reading, whichever is greater\u003cbr\u003e-10°C to 0°C: ±2.0\u003cbr\u003e-30°C to -10°C: ±3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time (95%)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 500 ms (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral response\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 to 14 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.10 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10:1 (calculated at 90% energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C (0.2°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability of readings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.8% of reading or \u0026lt; ±1.0°C (2°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAA battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 hours with laser and backlight on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePhysical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e255 g (8.99 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 60°C (-4°F to 140°F), (without battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10% to 90% RH non-condensing at 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 54 per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration and shock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61326-1: Portable electromagnetic equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Pollution degree 2\u003cbr\u003eIEC 60825-1: Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/62_max_brochure_f41d5bd1-dce8-4c69-ba42-3da8e4872d00.pdf?v=1660240090\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/62max_user_manual.pdf?v=1660240089\"\u003eUser's manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120876649,"sku":"FLUFLUKE62MAX","price":167.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-62max_03b_1500x1000_096ded2b-ba57-47ee-ba98-384bc84eb521.png?v=1660240156"},{"product_id":"fluke-handheld-ir-laser-thermometer-model-62max","title":"Fluke Handheld IR Laser Thermo Meter, Model 62Max+*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 62 MAX+ Handheld Infrared Laser Thermo Meter delivers the accuracy you need in an extremely rugged package. Just point, shoot, and read the temperature of many types of equipment. Get accurate readings form transformers, motors, pumps, panels, breakers, compressors, duct, steam lines, valves, and vents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy to use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IR thermometer’s small size and versatile features make it extremely easy to use. Plus, the lightweight form factor clips comfortably to your tool belt or belt loop, or easily fits in your toolbox. The 62 MAX+ offers a wide variety of features to take measurements quickly:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh and low alarms for rapid detection of measurements outside the limits\u003c\/li\u003e\n\u003cli\u003eDisplays Min\/Max\/Avg\/Dif\u003c\/li\u003e\n\u003cli\u003eThe minimum, maximum or average temperature, or the difference between two measurements\u003c\/li\u003e\n\u003cli\u003eEasy to read, even in dark areas with large, backlit display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWorks every place you need to go\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 62 MAX+ is rugged enough to take a three-meter drop – good news if you work from a ladder. Dual lasers help you target your measurement; the 12:1 distance to spot ratio helps get the reading you want. With its IP54 rating for dust and water resistance you can rely the Fluke 62 MAX+ to provide extremely accurate temperature measurements, rain or shine, even in dirty and dusty industrial sites.\u003c\/p\u003e\n\u003cp\u003ePowered by a single, standard AA battery.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely rugged – 3-meter drop tested, IP54 for dust and moisture\u003c\/li\u003e\n\u003cli\u003ePrecise dual-lasers for more accurate, repeatable measurements\u003c\/li\u003e\n\u003cli\u003eProvides up to a 12:1 Distance to spot ratio\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-30°C to 650°C (-22°F to 1202°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±1.0°C or ±1.0% of reading, whichever is greater\u003cbr\u003e-10°C to 0°C: ±2.0\u003cbr\u003e-30°C to -10°C: ±3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time (95%)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 500 ms (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral response\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 to 14 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.10 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12:1 (calculated at 90% energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C (0.2°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability of readings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.5% of reading or \u0026lt;±0.5°C (1°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAA battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 hours with laser and backlight on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePhysical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e255 g (8.99 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 60°C (-4°F to 140°F), (without battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10% to 90% RH non-condensing at 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 54 per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration and shock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61326-1: Portable electromagnetic equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Pollution degree 2\u003cbr\u003eIEC 60825-1: Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/62max_usermanual.pdf?v=1660161044\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/62_max_brochure.pdf?v=1660161044\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121794153,"sku":"FLUFLUKE62MAX+","price":314.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/62-max-plus-01b-1500x1000.png?v=1660235062"},{"product_id":"fluke-handheld-digital-thermometer-model-51-ii","title":"Fluke Handheld Digital Thermometer, Model 51-II*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 51 II single input digital thermometer delivers fast response with laboratory accuracy (0.05% + 0.3°C). You can use the 51 II to measure contact temperature on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or E-type thermocouple temperature sensors. The user friendly-front panel and large, backlit display make it easy to view results. And the sleep mode feature preserves battery life to give you a typical thousand hours of operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle Input digital thermometer for lab, QA, process calibration, food safety and HVAC\u003c\/li\u003e\n\u003cli\u003eMeasures J, K, T, and E-type thermocouples\u003c\/li\u003e\n\u003cli\u003ePresents results in °C, °F, or Kelvin (K) on a large backlit display\u003c\/li\u003e\n\u003cli\u003eIncludes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events\u003c\/li\u003e\n\u003cli\u003eEasy-to-access battery door that allows replacing the battery without breaking the calibration seal\u003c\/li\u003e\n\u003cli\u003eComes with splash- and dust-resistant case protected by an impact-absorbing holster and a three-year warranty\u003c\/li\u003e\n\u003cli\u003ePowered by three, standard AA batteries -30-\u003c\/li\u003e\n\u003cli\u003eIncludes an electronic offset function that compensates for thermocouple errors to maximize overall accuracy\u003c\/li\u003e\n\u003cli\u003eHandles temperatures up to 900°C (1600°F)\u003c\/li\u003e\n\u003cli\u003eProvides a user-friendly front panel that is easy to set up and operate\u003c\/li\u003e\n\u003cli\u003eOffers sleep mode to increase battery life; 1000-hour battery life typical\u003c\/li\u003e\n\u003cli\u003eOffers optional ToolPak accessory to hang the thermometer from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTemperature accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAbove -100°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, E, and N-type: ±[0.05% + 0.3°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eR and S-type: ±[0.05% + 0.4°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBelow -100°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eJ, K, E, and N-types: ±[0.20% + 0.3°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eT-type: ±[0.50% + 0.3°C]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eJ-type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-210°C to 1200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-type\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1372°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-type\u003c\/td\u003e\n\u003ctd\u003e-250°C to 400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-type\u003c\/td\u003e\n\u003ctd\u003e-150°C to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN-type\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1300°C\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR and S-type\u003c\/td\u003e\n\u003ctd\u003e0°C to 1767°C\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature scale\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eITS-90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable standards\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNIST-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C, 0.1 K \u0026lt; 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003e1°C, 1 K ≥ 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"nobold small-font\"\u003e1. Only the Fluke Models 53 II B and 54 II Bthermometers are capable of measuring N, R, and S-type thermocouples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% to 90%; 0°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003e0% to 70%; 0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCE, CSA, TÜV (pending)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e173 x 86 x 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 AA batteries; typical 1000-hour life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/52_ii_users_manual.pdf?v=1660155598\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122252905,"sku":"FLUFLUKE51260HZ","price":659.39,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F_51_2_01b_h_1500x1000_1.png?v=1660159940"},{"product_id":"fluke-dual-probe-digital-thermometer-model-52-ii","title":"Fluke Dual Probe Digital Thermometer, Model 52 II*","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 52 II dual-input digital thermometer delivers fast response with laboratory accuracy (0.05% + 0.3°C). You can use the 52 II to measure two contact temperature inputs simultaneously on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or E-type thermocouple temperature sensors. The user friendly-front panel and large, backlit display make it easy to view results from both inputs in multiple ways. And the sleep mode feature preserves battery life to give you a typical thousand hours of operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital thermometer for lab, QA, process calibration, food safety and HVAC\u003c\/li\u003e\n\u003cli\u003eShows any combination of T1, T2, T1-T2, plus MIN, MAX, or AVG on the large backlit dual display\u003c\/li\u003e\n\u003cli\u003eFeatures fast response and laboratory accuracy (0.05% + 0.3°C)\u003c\/li\u003e\n\u003cli\u003eIncludes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events\u003c\/li\u003e\n\u003cli\u003eEasy-to-access battery door that allows replacing the battery without breaking the calibration seal\u003c\/li\u003e\n\u003cli\u003eComes with splash- and dust-resistant case protected by an impact-absorbing holster and a three-year warranty\u003c\/li\u003e\n\u003cli\u003ePowered by three, standard AA batteries -30-\u003c\/li\u003e\n\u003cli\u003eFeatures an electronic offset function that compensates for thermocouple errors to maximize overall accuracy\u003c\/li\u003e\n\u003cli\u003eMeasures J, K, T, and E-type thermocouples\u003c\/li\u003e\n\u003cli\u003eHandles temperatures up to 900°C (1600°F)\u003c\/li\u003e\n\u003cli\u003ePresents results in °C, °F, or Kelvin (K)\u003c\/li\u003e\n\u003cli\u003eProvides a user-friendly front panel that is easy to set up and operate\u003c\/li\u003e\n\u003cli\u003eOffers sleep mode to increase battery life; 1000-hour battery life typical\u003c\/li\u003e\n\u003cli\u003eOffers optional ToolPak accessory to hang the thermometer from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTemperature accuracy\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cb\u003eAbove -100°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, E, and N-type: ±[0.05% + 0.3°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR and S-type: ±[0.05% + 0.4°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cb\u003eBelow -100°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eJ, K, E, and N-types: ±[0.20% + 0.3°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-type: ±[0.50% + 0.3°C]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eJ-type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-210°C to 1200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-type\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1372°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-type\u003c\/td\u003e\n\u003ctd\u003e-250°C to 400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-type\u003c\/td\u003e\n\u003ctd\u003e-150°C to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN-type\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1300°C\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR and S-type\u003c\/td\u003e\n\u003ctd\u003e0°C to 1767°C\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature scale\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eITS-90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable standards\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNIST-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C, 0.1 K \u0026lt; 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1°C, 1 K ≥ 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003e1. Only the Fluke Models 53 II B and 54 II thermometers are capable of measuring N, R, and S-type thermocouples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% to 90%; 0°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 70%; 0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSafety Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCE, CSA, TÜV (pending)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e173 x 86 x 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 AA batteries; typical 1000-hour life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/52_ii_users_manual.pdf?v=1660155598\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213123432553,"sku":"FLUFLUKE52260HZ","price":827.39,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/fluke-52-2-02b-1500x1000.png?v=1660155603"},{"product_id":"fluke-hvac-infrared-and-contact-thermometer-model-561","title":"Fluke HVAC Infrared and Contact Thermo Meter, Model 561*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 561 IR contact thermo meter combines the temperature measurement functions that industrial, electrical, and HVAC\/R professionals need in one tool. It is an IR thermometer for non-contact measurements, with K-type thermocouple capability for contact temperature measurement. It's fast, efficient, and easy to use, saving you valuable time and effort.\u003c\/p\u003e\n\u003cp\u003eUse the 561 IR capabilities to scan large areas or small objects quickly and efficiently, without having to shut down equipment. Measure hot, moving, electrically energized, and hard-to-reach objects instantly. Check motors, insulation, breakers, radiant heating, pipes, corroded connections, and wires. Plus, scan ducts, and other hard-to-reach objects from the floor and leave your ladder in the truck.\u003c\/p\u003e\n\u003cp\u003eYou can also use the Fluke 561's handy flexible pipe probe (included) to take super-heat or internal temperatures. Or plug in any industry standard type K mini connector thermocouple probe to take those measurements and preserve your investment in thermocouples you already own.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContact and non-contact IR thermometer for measuring up close or at a distance, without a ladder\u003c\/li\u003e\n\u003cli\u003eMeasures temperature from -40°C to 550° C (-40°F to 1022°F)\u003c\/li\u003e\n\u003cli\u003eWorks with all standard mini-connector type K thermocouples\u003c\/li\u003e\n\u003cli\u003eProvides single-point laser sighting\u003c\/li\u003e\n\u003cli\u003eAllows easy emissivity adjustment for measuring pipes and other shiny surfaces more accurately\u003c\/li\u003e\n\u003cli\u003eFeatures fabric hook-and-loop fastener pipe probe for superheat, sub-cooling, and other contact and ambient measurements\u003c\/li\u003e\n\u003cli\u003eProvides MIN, MAX, and DIF functions to help you quickly identify problems\u003c\/li\u003e\n\u003cli\u003eWeighs only 12 ounces\/340 grams) and is extremely easy to use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 550°C (-40 to 1022°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F) of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD:S (distance to spot size)\u003c\/td\u003e\n\u003ctd\u003e12:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eEasy emissivity selector\u003c\/td\u003e\n\u003ctd\u003eAdjustable with three settings:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eLow (0.3), medium (0.7). high (0.95)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay accuracy [assumes ambient operating temperature of 23°C (73°F) to 25°C (77°F)]\u003c\/td\u003e\n\u003ctd\u003e±1.0% of reading ±1% of reading or ±1°C (±2°F), whichever is greater below 0°C \/ 32°F, ±1°C (±2°F) ±0.1°\/1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e500 mSec (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e±0.5% of reading or ±1°C (±2°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral response\u003c\/td\u003e\n\u003ctd\u003e8 µm to 14 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser sighting\u003c\/td\u003e\n\u003ctd\u003eSingle point laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser shutoff\u003c\/td\u003e\n\u003ctd\u003eLaser turns off above ambient temperature of 40°C (104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser power\u003c\/td\u003e\n\u003ctd\u003eClass 2(II) operation; Output \u0026lt; 1 mW, wavelength 630-670 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH non-condensing, at \u0026lt; 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower, battery life\u003c\/td\u003e\n\u003ctd\u003e2 AA batteries (alkaline or NiCD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay hold\u003c\/td\u003e\n\u003ctd\u003e7 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklit display\u003c\/td\u003e\n\u003ctd\u003eYes, LCD with dual temperatures (current and MAX\/MIN\/DIF\/KTC), low battery, F\/C indicator, and Scan\/Hold options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C (32°F to 120°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 65°C (-25°F to 150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAX, MIN, DIF temperatures\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Type K mini adapter input\u003c\/td\u003e\n\u003ctd\u003eYes, compatible with industry standard K type probes with mini-connector. Displays to the thermometer temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Type K fabric hook-and-loop fastener pipe probe\u003c\/td\u003e\n\u003ctd\u003eYes, with a temperature range of 0°C to 100°C (32°F to 212°F) and accuracy of ±2.2°C (±4°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVAC measurement guide\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/561_brochure.PDF?v=1660236638\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/561_user_s_manual.pdf?v=1660236637\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213123530857,"sku":"FLUFLUKE561","price":454.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-561_01b_1500x1000_bd5067d2-b0d6-487f-9041-56deec412e4f.png?v=1660236681"}],"url":"https:\/\/orka.ca\/collections\/fluke-temperature-measurement-tools.oembed","provider":"Orka","version":"1.0","type":"link"}