{"title":"Fluke - Clamp Meters","description":"","products":[{"product_id":"fluke-true-rms-clamp-meter-fc-ac-dc-with-iflex-model-376-fc","title":"Fluke True-RMS Clamp Meter FC AC\/DC with iFlex, Model 376-FC","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.\u003c\/p\u003e\n\u003ch3\u003eFind the cause of difficult problems\u003c\/h3\u003e\n\u003cp\u003eThe 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.\u003cbr\u003e\u003cbr\u003eMeasure:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage to 1000 V AC or DC\u003c\/li\u003e\n\u003cli\u003eResistance to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e500 mV DC measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003cli\u003eWork safely and conveniently\u003c\/li\u003e\n\u003cli\u003eThe 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe included 18-inch or 36-inch iFlex flexible current probe provides easier access to large conductors in tight spaces. The flexible probe:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExpands the measurement range to 2500 A AC\u003c\/li\u003e\n\u003cli\u003eAllows frequency measurement to 500 Hz with body jaw and iFlex\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures AC\/DC current with included 18-inch or 36-inch iFlex current probe\u003c\/li\u003e\n\u003cli\u003eVFD low pass filter for accurate measurements of non-linear signals\u003c\/li\u003e\n\u003cli\u003eRemotely log, trend and monitor to pinpoint intermittent faults\u003c\/li\u003e\n\u003cli\u003eInrush measurement to filter out noise and capture starting current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable width=\"100%\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003eAC Current via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"4\"\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2% ±5 digits (10 Hz to 100 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e2.5% ±5 digits (100-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" colspan=\"4\"\u003eCrest Factor (50 Hz\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e3 @ 500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e2.5 @ 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eAC Current via Flexible Current Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"4\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.1 A (≤ 600 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e1 A (≤ 2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e3% ±5 digits (5 – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" colspan=\"4\"\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e3.0 at 1100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e2.5 at 1400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e1.42 at 2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cimg width=\"150\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/iflex-highres-cropped.png\" height=\"209\" alt=\"Flexible current probe\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ei2500-10 Flex\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003ei2500-18 Flex\u003c\/td\u003e\n\u003ctd\u003ei2500-36 Flex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e4.8 in (122.2 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.5 %\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±0.5 %\u003c\/td\u003e\n\u003ctd\u003e±0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003ctd\u003e5.3 in (133.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±1.0 %\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±1.0 %\u003c\/td\u003e\n\u003ctd\u003e±1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003ctd\u003e5.8 in (147.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±2.0 %\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±2.0 %\u003c\/td\u003e\n\u003ctd\u003e±2.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eDC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eAC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 V (≤600.0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1% ±5 digits (20 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eDC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 V (≤600.0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003emV dc\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e500.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eFrequency via Jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" colspan=\"2\"\u003eTrigger level \u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e5 Hz to 10 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e10 Hz to 100 Hz, ≥5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e100 Hz to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eFrequency via Flexible Current Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" colspan=\"2\"\u003eTrigger level \u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e5 Hz to 20 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e20 Hz to 100 Hz, ≥20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e100 Hz to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e60 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 Ω (≤600 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e1 Ω (≤6000 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e10 Ω (≤60 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 μF (≤ 100 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e1 μ F (≤ 1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" colspan=\"2\"\u003eOperating humidity -\u003cbr\u003enon-condensing (\u0026lt; 10°C)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e≤90% RH (at 10 °C to 30 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e≤75% RH (at 30 °C to 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e≤45% RH (at 40 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e249 x 85 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e395 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eJaw opening\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFlexible current probe diameter\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFlexible current probe cable length\u003cbr\u003e(head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" colspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eIEC 61010-1, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eIEC 61010-2-033:CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRadio Frequency Certification FCC ID\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eT68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eElectromagnetic Compatibility (EMC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" colspan=\"2\"\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eCISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eClass A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTemperature coefficients\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374fc_user_manual.pdf?v=1660244557\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374_fc_datasheet.pdf?v=1660244557\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374_fc_brochure.PDF?v=1660244557\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120581737,"sku":"FLUFLUKE376FC","price":899.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-376fc-16a-1500x1000.png?v=1660245108"},{"product_id":"fluke-hvac-clamp-meters-true-rms-model-902-fc","title":"Fluke HVAC Clamp Meters, True-RMS, Model 902 FC*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 902 FC Clamp Meter, with Fluke Connect wireless connectivity, can help HVAC technicians improve productivity in the field. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to perform many essential HVAC system measurements: microamps for testing pilot light sensors; resistance up to 60 kΩ; AC current and AC\/DC voltage; capacitance; and contact temperature, all with just one tool. Plus its small form factor makes it easy to hang on to and navigate in tight work spaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAs part of the Fluke Connect family, the 902 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. No need to write down the results. Trend and monitor measurements live on your phone screen, and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email, and collaborate in real time with other colleagues with ShareLive™ video calls or email.\u003c\/p\u003e\n\u003cp\u003eThe 902 FC can also decrease the frequency of wearing personal protective equipment (PPE) when working on high voltage\/current panels. Simply turn off the panel. Verify that it is de-energized using standard safety procedures. Place the clamp and synch it to a smartphone. Close the panel, reenergize it, and take measurements from a safe distance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the box:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e902 FC Clamp Meter\u003c\/li\u003e\n\u003cli\u003e(1 pair) TL75 test leads\u003c\/li\u003e\n\u003cli\u003e80BK integrated DMM temperature probe\u003c\/li\u003e\n\u003cli\u003e2 AA Alkaline Batteries (Installed)\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA wireless Fluke Connect®-enabled clamp meter designed specifically for the needs of HVAC technicians\u003c\/li\u003e\n\u003cli\u003eOffers 200 µA DC current measurements to measure flame rod\u003c\/li\u003e\n\u003cli\u003eExtends resistance range to measure thermistors up to 60kΩ\u003c\/li\u003e\n\u003cli\u003eCaptures flue gas temperature\u003c\/li\u003e\n\u003cli\u003eMeasures start and run motor capacitors\u003c\/li\u003e\n\u003cli\u003eMeasures variable frequency drive performance\u003c\/li\u003e\n\u003cli\u003eErgonomic design fits in your hand and can be used while wearing personal protective equipment\u003c\/li\u003e\n\u003cli\u003eLarge, easy-to-read backlit display improves readings in low light settings\u003c\/li\u003e\n\u003cli\u003eConnects to your smartphone via Fluke Connect so you can read measurements at a safer distance\u003c\/li\u003e\n\u003cli\u003eMeasures AC current to 600 A and AC and DC voltage to 600 V\u003c\/li\u003e\n\u003cli\u003eMeasures capacitance to 1000 µF and DC current to 200 µA\u003c\/li\u003e\n\u003cli\u003eMeasures temperature from -10 °C to 400 °C (14 °F to 752 °F)\u003c\/li\u003e\n\u003cli\u003eOffers True-RMS voltage and current measurements to accurately measure non-linear signals\u003c\/li\u003e\n\u003cli\u003eMeasures resistance to 60 kΩ\u003c\/li\u003e\n\u003cli\u003eOffers Min\/Max recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003eRuns on two AA alkaline batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFunction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eA ac (via Jaw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2.0% ±5 digit (45-65 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e2.5% ±5 digit (65-400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCrest Factor (50Hz or 60Hz)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003cspan\u003e \u003c\/span\u003eMIN@220\u003cspan\u003e \u003c\/span\u003eA\u003cbr\u003e\u0026gt; 1.4\u003cspan\u003e \u003c\/span\u003eMIN@600\u003cspan\u003e \u003c\/span\u003eA\u003cbr\u003eAdd 2% for CF\u0026gt;400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eV ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eV dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eOhms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1\/1\/10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600\/6000\/60.00 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1\/1 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e100.0\/1000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eµA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e200 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eContact temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 C\/F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% ±8 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-40 to 400 °C (-40 °F to 752 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eContinuity beeper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeeper volume\u003c\/td\u003e\n\u003ctd\u003e75 dBA nom. 15 cm. from case front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn threshold\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=30 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 AA alkaline batteries, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperating: -10 °C to +50 °C (14 °F to +122 °F)\u003cbr\u003eStorage: -40 °C to +60 °C (-40 °F to +140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNon condensing (\u0026lt; 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperating: 3,000 m (9,842 ft)\u003cbr\u003eStorage: 12,000 m (39,370 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (meter only)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e419 g (15 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1, Pollution Degree 2\u003cbr\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003cbr\u003eIEC 61010-2-033: CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Frequency Certification\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFCC ID:T68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInternational: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficients\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAdd 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/902_user_manual.pdf?v=1660236147\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120909417,"sku":"FLUFLUKE902FC","price":461.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/902-fc-hvac_clamp-meter-1500x1000.png?v=1660236186"},{"product_id":"fluke-true-rms-clamp-multimeter-model-325","title":"Fluke True-RMS Clamp Multimeter, Model 325*","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 325 True-rms Clamp Meter is a reliable, versatile troubleshooting tool for commercial and residential electricians. Featuring a slim design for easy transport and use, and a large display for efficient troubleshooting. In addition to true-rms AC current and voltage on non-linear loads, the 325 measures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDC current\u003c\/li\u003e\n\u003cli\u003eDC voltage\u003c\/li\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eFrequency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou’ll carry fewer tools in your bag and get more work done.\u003c\/p\u003e\n\u003cp\u003eThe 325 gives you a strong combination of measurement functions, in a tool that is reliable, easy-to-use and affordable. This clamp meter offers True-rms AC voltage and current measurements on non-linear signals. Paired with the CAT III 600 V, CAT IV 300 V safety rating the clamp meter can also measure:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures AC\/DC current up to 400 A through jaw\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage to 600 V using test leads\u003c\/li\u003e\n\u003cli\u003eMeasures frequency from 5 Hz to 500 Hz; resistance to 40 kΩ\u003c\/li\u003e\n\u003cli\u003eMeasures temperature from -10 °C to 400 °C with included K-type thermocouple\u003c\/li\u003e\n\u003cli\u003eMin\/Max function records important values\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eComes with a two-year warranty\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-rms AC\/DC current, voltage, temperature, frequency\u003c\/li\u003e\n\u003cli\u003eClamp meter, test leads, K-type thermocouple and soft case\u003c\/li\u003e\n\u003cli\u003eVersatile tool performs most front-line measurement tasks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" rowspan=\"2\"\u003eAC current\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e40.00 A \/ 400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% ± 5 digits (45 Hz to 65 Hz)\u003cbr\u003e2.5% ± 5 digits (65 Hz to 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e40.00 A \/ 400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω \/ 4000 Ω \/ 40.00 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤ 30 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e0 to 100.0 μF \/ 100μF to 1000 μF\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAC response\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContact temperature\u003c\/td\u003e\n\u003ctd\u003e-10.0°C to 400.0°C (14.0°F to 752.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMin\/Max\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eH x W x D (mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e207 x 75 x 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax wire diameter\u003c\/td\u003e\n\u003ctd\u003e30 mm (600 MCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e283 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCategory rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003cbr\u003eCAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eTwo-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_user_manual.pdf?v=1660246448\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_quick_reference.pdf?v=1660246448\"\u003eQuick Reference\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_brochure.PDF?v=1660246448\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120974953,"sku":"FLUFLUKE325","price":613.19,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-325-01c-1500x1000.png?v=1660246490"},{"product_id":"fluke-true-rms-digital-clamp-meter-model-323","title":"Fluke True-RMS Digital Clamp Meter, Model 323","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 323 clamp meter is a good basic troubleshooting tool for commercial and residential electricians. It includes True RMS measurements, optimized ergonomics, and large display for efficient troubleshooting. It's designed to perform in the toughest environments and provide noise-free, reliable results, so you can trust it to help you confidently diagnose problems almost anywhere. Use it to verify the presence of load current, AC voltage, and continuity of circuits, switches, fuses and contacts. Its slim, compact size and rugged design make it well suited for measuring current up to 400 A in tight cable compartments.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 323 comes with a two-year warranty and a soft carrying case.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, reliable basic True-RMS clamp meter for measuring current up to 400 A\u003c\/li\u003e\n\u003cli\u003eMeasures AC current to 400 A\u003c\/li\u003e\n\u003cli\u003eMeasures AC voltage and DC voltage to 600 V\u003c\/li\u003e\n\u003cli\u003eProvides True RMS AC voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eMeasures resistance to 4 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eFeatures slim, ergonomic design for measuring in tight cable compartments\u003c\/li\u003e\n\u003cli\u003ePresents measurements on a large, easy-to-read display\u003c\/li\u003e\n\u003cli\u003eHold function captures a reading on the display\u003c\/li\u003e\n\u003cli\u003eFeatures a CAT III 600 V, CAT IV 300 V safety rating\u003c\/li\u003e\n\u003cli\u003eComes with a two-year warranty and soft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" rowspan=\"2\"\u003eAC current\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% ± 5 digits (45 Hz to 65 Hz)\u003cbr\u003e2.5% ± 5 digits (65 Hz to 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω\/ 4000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤ 70 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAC response\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContact temperature\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMin\/Max\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eH x W x D (mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e207 x 75 x 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax wire diameter\u003c\/td\u003e\n\u003ctd\u003e30 mm (600 MCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e265 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCategory rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003cbr\u003eCAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eTwo-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_user_manual.pdf?v=1660246448\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_user_manual.pdf?v=1660246448\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_quick_reference.pdf?v=1660246448\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_quick_reference.pdf?v=1660246448\"\u003eQuick Reference\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_brochure.PDF?v=1660246448\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_brochure.PDF?v=1660246448\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121400937,"sku":"FLUFLUKE323","price":291.19,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-323-01c-1500x1000_1.png?v=1660247597"},{"product_id":"fluke-true-rms-ac-dc-clamp-meter-model-375-fc","title":"Fluke True-RMS AC\/DC Clamp Meter, Model 375-FC*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 375 FC, part of the Fluke Connect family of wireless test tools, delivers high performance features and ease of use. It features a VFD low-pass filter for accurate motor drive measurements and wireless communications to transmit results to a smartphone via Fluke Connect\u003c\/p\u003e\n\u003cp\u003eThe 375 FC offers most of the features of the Fluke 376 FC including compatibility with the iFlex flexible current probe but, unlike the 376 FC, it does not include the iFlex® probe in the package. You can measure AC and DC current to 600 A and voltage up to 1000 V with the fixed jaw clamp. Or connect an optional iFlex® flexible current probe to expand your measurement range to 2500 A AC. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access individual wires.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUsing its Bluetooth connectivity to Apple and Android devices, you can read the 375 FC results a safe distance away on your smartphone, wearing less PPE. You can create and send reports in email right from the field and save results to the cloud. You can also converse with colleagues in real-time with ShareLive™ video calls.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith True-RMS AC voltage and current measurements, the 375 enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 375 FC Clamp Meter is the direct replacement for the Fluke 375 Clamp Meter.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance clamp meter that measures very low voltage and high resistance\u003c\/li\u003e\n\u003cli\u003eTransmits measurements to your smartphone via Fluke Connect® so you can view them at a safer distance\u003c\/li\u003e\n\u003cli\u003eMeasures AC and DC current to 600 A, and AC and DC voltage to 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasures AC current to 2500 A AC with optional iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003eCompatible with optional TPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eComes with batteries, soft carrying case, and three-year warranty\u003c\/li\u003e\n\u003cli\u003eFeatures CAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eMeasures capacitance to 1000 µF\u003c\/li\u003e\n\u003cli\u003eIncludes True-RMS voltage and current measurements to accurately measure non-linear signals\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 500 Hz and resistance to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eIncludes Min\/Max\/Avg and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003eOffers 500 mV DC measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli\u003eRuns on two AA alkaline batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAC Current via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% ±5 digits (10 Hz to 100 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e2.5% ±5 digits (100-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCrest Factor (50 Hz\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 @ 500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e2.5 @ 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC Current via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A (≤ 600 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 A (≤ 2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3% ±5 digits (5 – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.0 at 1100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e2.5 at 1400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1.42 at 2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePosition Sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cspan\u003e\u003cimg alt=\"Flexible current probe\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/37x_position_sens_100x181.png\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-10 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-18 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd\u003e±0.5 %\u003c\/td\u003e\n\u003ctd\u003e±0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd\u003e±1.0 %\u003c\/td\u003e\n\u003ctd\u003e±1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd\u003e±2.0 %\u003c\/td\u003e\n\u003ctd\u003e±2.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 V (≤600.0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% ±5 digits (20 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 V (≤600.0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003emV dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTrigger level \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 Hz to 10 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e10 Hz to 100 Hz, ≥5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTrigger level \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 Hz to 20 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e20 Hz to 100 Hz, ≥20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e100 Hz to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e60 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Ω (≤600 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 Ω (≤6000 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e10 Ω (≤60 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 μF (≤ 100 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 μ F (≤ 1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eOperating humidity -\u003cbr\u003enon-condensing (\u0026lt; 10°C)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≤90% RH (at 10 °C to 30 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e≤75% RH (at 30 °C to 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e249 x 85 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e395 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe diameter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe cable length\u003cbr\u003e(head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Frequency Certification FCC ID\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eT68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eCISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eClass A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficients\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374fc_user_manual.pdf?v=1660244557\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374_fc_datasheet.pdf?v=1660244557\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374_fc_brochure.PDF?v=1660244557\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121433705,"sku":"FLUFLUKE375FC","price":852.59,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-375fc-01a-1500x1000.png?v=1660244900"},{"product_id":"fluke-clamp-meter-non-contact-voltage-trus-rms-ac-dc-with-iflex-model-378-fc","title":"Fluke Clamp Meter, Non-Contact Voltage Trus-RMS AC\/DC with iFlex, Model 378 FC*","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 378 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, the 378 FC will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe included iFlex flexible current probe lets you measure ac current as high as 2500 A. Crowded wiring cabinets and large conductors are easily measured with the iFlex probe.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eYour job will get easier when you use the 378 FC clamp meter. The display turns green when a stable FieldSense measurement is detected. Visual Continuity also provides a bright green screen for easy detection of continuity in noisy work areas.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure voltage and current with your clamp jaw\u003c\/li\u003e\n\u003cli\u003eFaster, safer testing - all without touching a live wire - using FieldSense™ technology\u003c\/li\u003e\n\u003cli\u003ePower quality indicator shows whether equipment or power line is faulty\u003c\/li\u003e\n\u003cli\u003eComplete 3-phase voltage and current tests in 3 quick steps\u003c\/li\u003e\n\u003cli\u003eValues are displayed on your smart phone and saved to the cloud via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003ePhase rotation auto-calculated and shown on the Fluke Connect software\u003c\/li\u003e\n\u003cli\u003eNo more hand-written notes or complicated math.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\" colspan=\"3\"\u003eGeneral specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Maximum Voltage between any Terminal and Earth Ground\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e2 AA IEC LR6 alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife\u003c\/td\u003e\n\u003ctd\u003e200 hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDual readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"width: 513.367px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eElectrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eAC Current: Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e2 % ±5 digits (45 Hz to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e3 @ 500 A\u003cbr\u003e2.5 @ 600 A\u003cbr\u003e1.42 @ 1000 A\u003cbr\u003eAdd 2 % for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eAC Current: Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e1 A (≤2500 A) 0.1 A (≤999.9 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e3 % ±5 digits (5 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e3.0 at 1100 A\u003cbr\u003e2.5 at 1400 A\u003cbr\u003e1.42 at 2500 A\u003cbr\u003eAdd 2 % for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003ePosition Sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 140px;\"\u003e\u003cimg alt=\"Flexible current probe\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/37x_position_sens_100x181.png\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 121px;\"\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd style=\"width: 96px;\"\u003ei2500-10 Flex\u003c\/td\u003e\n\u003ctd style=\"width: 96px;\"\u003ei2500-18 Flex\u003c\/td\u003e\n\u003ctd style=\"width: 28.367px;\"\u003eError\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 121px;\"\u003eA\u003c\/td\u003e\n\u003ctd style=\"width: 96px;\"\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd style=\"width: 96px;\"\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd style=\"width: 28.367px;\"\u003e± 0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 121px;\"\u003eB\u003c\/td\u003e\n\u003ctd style=\"width: 96px;\"\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd style=\"width: 96px;\"\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003ctd style=\"width: 28.367px;\"\u003e± 1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 121px;\"\u003eC\u003c\/td\u003e\n\u003ctd style=\"width: 96px;\"\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd style=\"width: 96px;\"\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003ctd style=\"width: 28.367px;\"\u003e± 2.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eDC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e2 % ±5 digits\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003e\n\u003csup\u003e[1]\u003c\/sup\u003eWhen using the ZERO function to compensate for offsets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eAC Voltage: Field Sense\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e1 V (≤1000V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 140px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 121px;\"\u003e≤4\/0 AWG\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 220.367px;\"\u003e3 % ±5 digits (45 Hz to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 121px;\"\u003e≥4\/0 AWG\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 220.367px;\"\u003e5 % ±5 digits (45 Hz to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003ePosition wire as close as possible to jaw opening (see illustration).\u003cimg height=\"173\" width=\"316\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/WirePositioning.jpg\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eAC Voltage: Test Leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e600.0 V 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e0.1 V (≤600.0 V)\u003cbr\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e1 % ±5 digits (20 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e600.0 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e0.1 V (≤600.0 V)\u003cbr\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e1 % ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003emV dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e500.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e1 % ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eAmps Frequency: Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e45 Hz to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e0.5 % ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eTrigger Level\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e5 Hz to 10 Hz, ≥10 A\u003cbr\u003e10 Hz to 100 Hz, ≥ 5 A\u003cbr\u003e100 Hz to 500 Hz, ≥ 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eAmps Frequency: Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e0.5 % ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eTrigger Level\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e5 Hz to 20 Hz, ≥25 A\u003cbr\u003e20 Hz to 100 Hz, ≥20 A\u003cbr\u003e100 Hz to 500 Hz,≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e60.00 kΩ\u003cbr\u003e6000 Ω\u003cbr\u003e600.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e0.1 Ω (≤600.0 Ω)\u003cbr\u003e1 Ω (≤6000 Ω)\u003cbr\u003e10 Ω (≤60.00 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e1 % ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e0.1 μF (≤100.0 μF)\u003cbr\u003e1 μF (≤1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e1 % ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eMechanical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e274 mm x 86 mm x 47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eWeight (with Batteries)\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e463 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eFlexible Current Probe Diameter\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eFlexible Current Probe Cable Length (head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRogowski Coil Length\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e-10 °C to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e-40 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eOperating Humidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003eNon condensing (\u0026lt;10 °C)\u003cbr\u003e≤90 % RH (10 °C to 30 °C)\u003cbr\u003e≤75 % RH (30 °C to 40 °C)\u003cbr\u003e≤45 % RH (40 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eTemperature Coefficients\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003eAdd 0.1 x specified accuracy for each degree C \u0026gt;28 °C or \u0026lt;18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eIngress Protection\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003eIEC 60529: IP30 (jaw closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e12 000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" style=\"width: 140px;\"\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 121px;\"\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 220.367px;\"\u003eIEC 61326-1: Portable Electromagnetic Environment\u003cbr\u003eIEC 61326-2-2, CISPR 11: Group 1, Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e\u003cspan\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e\u003cspan\u003eClass B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.\u003cbr\u003eEmissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 121px;\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 220.367px;\"\u003eClass A equipment (Industrial Broadcast \u0026amp; Communications Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e\u003cspan\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eSafety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eGeneral\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003eIEC 61010-1: Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003cbr\u003eIEC 61010-2-033: CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eCurrent Clamp for Leakage Current Measurements\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003eIEC 61557-13: Class 2, ≤30 A\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 481.367px;\"\u003eWireless Radio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRadio Frequency Certification\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003eFCC ID: T68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e2405 MHz to 2480 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eOutput Power\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e\u0026lt;100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 140px;\"\u003eRadio Frequency Data\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 341.367px;\"\u003e\n\u003ca href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/radio_a_iseng0500.pdf\" target=\"_blank\"\u003eRadio Frequency Data For Class A Devices\u003c\/a\u003e\u003cbr\u003eSIMPLIFIED EU DECLARATION OF CONFORMITY\u003cbr\u003eHereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014\/53\/EU. The full text of the EU declaration is available at the following internet address:\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/FLK_RED_1aeng0900.pdf\" target=\"_blank\"\u003ehttps:\/\/dam-assets.fluke.com\/s3fs-public\/FLK_RED_1aeng0900.pdf\u003c\/a\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/378fc.pdf?v=1660070547\"\u003eUser's manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/378fc_quick_ref.pdf?v=1660070546\"\u003eQuick Reference\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121695849,"sku":"FLUFLUKE378FC","price":1319.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F-378fc_01a_w.png?v=1660070421"},{"product_id":"fluke-true-rms-ac-dc-clamp-meter-model-374-fc","title":"Fluke True-RMS AC\/DC Clamp Meter, Model 374 FC*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 374 FC, part of the Fluke Connect family of wireless test tools, delivers the standard features you need for everyday troubleshooting. Measure AC and DC current to 600 A with the fixed jaw clamp or add an optional iFlex® flexible current probe to measure all the way to 2500 A. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access tightly packed wires. You can also use the 374 FC to measure AC and DC voltage to 1000 V and resistance to 6000 Ω.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 374 FC is Fluke Connect-enabled to wirelessly transmit results via Bluetooth to Apple and Android devices. That means you can read the results out of the arc flash zone, wearing less PPE. You can even save results to the cloud and create and send reports in email right from the field. Or converse in real-time with ShareLive™ video calls.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith True-RMS AC voltage and current measurements, the 374 FC enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 374 FC Clamp Meter is the direct replacement for the Fluke 374 Clamp Meter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the box:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e374 FC AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003e(1 pair) TL75 test leads\u003c\/li\u003e\n\u003cli\u003eTwo AA Alkaline batteries (Installed)\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced clamp meter that transmits measurements to your smartphone via Fluke Connect® for viewing at a safer distance\u003c\/li\u003e\n\u003cli\u003ePerforms AC and DC current measurements to 600 A, and AC and DC voltage measurements to 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasures AC current to 2500 A AC with optional iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003eMeasures resistance to 6000 Ω with continuity detection\u003c\/li\u003e\n\u003cli\u003eCompatible with optional TPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eComes with soft carrying case, batteries, and three-year warranty\u003c\/li\u003e\n\u003cli\u003eMeasures capacitance to 1000 µF\u003c\/li\u003e\n\u003cli\u003eFeatures CAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eProvides True-RMS voltage and current measurements to accurately measure non-linear signals\u003c\/li\u003e\n\u003cli\u003eIncludes Min\/Max\/Avg and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003eRuns on two AA alkaline batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eAC Current via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2% ±5 digits (10 Hz to 100 Hz)\u003cbr\u003e2.5% ±5 digits (100-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50 Hz\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.5 @ 600 A\u003cbr\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Current via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A (≤ 600 A)\u003cbr\u003e1 A (≤ 2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3% ±5 digits (5 – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.5 at 1400 A\u003cbr\u003e1.42 at 2500 A\u003cbr\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003ePosition Sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/37x_position_sens_100x181.png\" alt=\"Flexible current probe\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cb\u003eDistance from Optimum\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-10 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-18 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eError\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e±0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eB\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003ctd\u003e±1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003ctd\u003e±2.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" class=\"small-font nobold\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V (≤600.0 V)\u003cbr\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.5% ±5 digits (20 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V (≤600.0 V)\u003cbr\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003emV dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e500.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Ω (≤600 Ω)\u003cbr\u003e1 Ω (≤6000 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 μF (≤ 100 μF)\u003cbr\u003e1 μ F (≤ 1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMechanical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity -\u003cbr\u003enon-condensing (\u0026lt; 10°C)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤90% RH (at 10 °C to 30 °C)\u003cbr\u003e≤75% RH (at 30 °C to 40 °C)\u003cbr\u003e≤45% RH (at 40 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e249 x 85 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e395 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe diameter\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe cable length\u003cbr\u003e(head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 61010-1, Pollution Degree 2\u003cbr\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003cbr\u003eIEC 61010-2-033:CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Frequency Certification FCC ID\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eT68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2\u003cbr\u003eCISPR 11: Group 1, Class A\u003cbr\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003cbr\u003eClass A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003cbr\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficients\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374fc_user_manual.pdf?v=1660244557\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374_fc_datasheet.pdf?v=1660244557\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374_fc_brochure.PDF?v=1660244557\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121826921,"sku":"FLUFLUKE374FC","price":629.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-374fc-05a-1500x1000.png?v=1660244625"},{"product_id":"fluke-clamp-meter-true-rms-non-contact-voltage-ac-dc-with-iflex-model-377-fc","title":"Fluke Clamp Meter, True-rms Non-Contact Voltage AC\/DC with iFlex, Model 377 FC*","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUse the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eYour job will get easier when you use the 377 FC clamp meter. The display turns green when a stable FieldSense measurement is detected. Visual Continuity also provides a bright green screen for easy detection of continuity in noisy work areas.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows you to gather data as the basis for a preventive maintenance program.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete 3-phase voltage and current tests in 3 easy steps\u003c\/li\u003e\n\u003cli\u003eFull set of phase-to-ground and phase-to-phase values calculated and shown on the meter\u003c\/li\u003e\n\u003cli\u003eValues are also displayed on your smart phone and saved to the cloud via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003ePhase rotation auto-calculated and shown on the Fluke Connect software\u003c\/li\u003e\n\u003cli\u003eNo more hand-written notes or complicated math.\u003c\/li\u003e\n\u003cli\u003eMeasure voltage and current with your clamp jaw\u003c\/li\u003e\n\u003cli\u003eFaster, safer testing - all without touching a live wire - using FieldSense™ technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"head\"\u003eGeneral specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Maximum Voltage between any Terminal and Earth Ground\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e2 AA IEC LR6 alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife\u003c\/td\u003e\n\u003ctd\u003e200 hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDual readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eElectrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eAC Current: Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2 % ±5 digits (45 Hz to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3 @ 500 A\u003cbr\u003e2.5 @ 600 A\u003cbr\u003e1.42 @ 1000 A\u003cbr\u003eAdd 2 % for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Current: Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 A (≤2500 A) 0.1 A (≤999.9 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3 % ±5 digits (5 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3.0 at 1100 A\u003cbr\u003e2.5 at 1400 A\u003cbr\u003e1.42 at 2500 A\u003cbr\u003eAdd 2 % for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003ePosition Sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/37x_position_sens_100x181.png\" alt=\"Flexible current probe\"\u003e\u003c\/td\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd\u003ei2500-10 Flex\u003c\/td\u003e\n\u003ctd\u003ei2500-18 Flex\u003c\/td\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e± 0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003ctd\u003e± 1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003ctd\u003e± 2.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2 % ±5 digits\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003csup\u003e[1]\u003c\/sup\u003eWhen using the ZERO function to compensate for offsets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Voltage: Field Sense\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 V (≤1000V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e≤4\/0 AWG\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e3 % ±5 digits (45 Hz to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e≥4\/0 AWG\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e5 % ±5 digits (45 Hz to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003ePosition wire as close as possible to jaw opening (see illustration).\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/WirePositioning.jpg\" width=\"476\" height=\"261\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Voltage: Test Leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600.0 V 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V (≤600.0 V)\u003cbr\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 % ±5 digits (20 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600.0 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V (≤600.0 V)\u003cbr\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 % ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003emV dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e500.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 % ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAmps Frequency: Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e45 Hz to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.5 % ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5 Hz to 10 Hz, ≥10 A\u003cbr\u003e10 Hz to 100 Hz, ≥ 5 A\u003cbr\u003e100 Hz to 500 Hz, ≥ 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAmps Frequency: Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.5 % ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5 Hz to 20 Hz, ≥25 A\u003cbr\u003e20 Hz to 100 Hz, ≥20 A\u003cbr\u003e100 Hz to 500 Hz,≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e60.00 kΩ\u003cbr\u003e6000 Ω\u003cbr\u003e600.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Ω (≤600.0 Ω)\u003cbr\u003e1 Ω (≤6000 Ω)\u003cbr\u003e10 Ω (≤60.00 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 % ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 μF (≤100.0 μF)\u003cbr\u003e1 μF (≤1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 % ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMechanical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e274 mm x 86 mm x 47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with Batteries)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e463 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Diameter\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Cable Length (head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRogowski Coil Length\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-10 °C to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-40 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eNon condensing (\u0026lt;10 °C)\u003cbr\u003e≤90 % RH (10 °C to 30 °C)\u003cbr\u003e≤75 % RH (30 °C to 40 °C)\u003cbr\u003e≤45 % RH (40 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficients\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eAdd 0.1 x specified accuracy for each degree C \u0026gt;28 °C or \u0026lt;18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 60529: IP30 (jaw closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e12 000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eIEC 61326-1: Portable Electromagnetic Environment\u003cbr\u003eIEC 61326-2-2, CISPR 11: Group 1, Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cspan\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cspan\u003eClass B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.\u003cbr\u003eEmissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eClass A equipment (Industrial Broadcast \u0026amp; Communications Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cspan\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eSafety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 61010-1: Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003cbr\u003eIEC 61010-2-033: CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Clamp for Leakage Current Measurements\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 61557-13: Class 2, ≤30 A\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eWireless Radio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Frequency Certification\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eFCC ID: T68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2405 MHz to 2480 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt;100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Frequency Data\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003ca href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/radio_a_iseng0500.pdf\" target=\"_blank\"\u003eRadio Frequency Data For Class A Devices\u003c\/a\u003e\u003cbr\u003eSIMPLIFIED EU DECLARATION OF CONFORMITY\u003cbr\u003eHereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014\/53\/EU. The full text of the EU declaration is available at the following internet address:\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/FLK_RED_1aeng0900.pdf\" target=\"_blank\"\u003ehttps:\/\/dam-assets.fluke.com\/s3fs-public\/FLK_RED_1aeng0900.pdf\u003c\/a\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/378fc.pdf?v=1660070547\"\u003eUser's manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/378fc_quick_ref.pdf?v=1660070546\"\u003eQuick Reference\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122351209,"sku":"FLUFLUKE377FC","price":1087.19,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F-377fc_01a_w.png?v=1660071576"},{"product_id":"fluke-milliamp-clamp-meter-4-20-ma-multimeter-model-771","title":"Fluke Milliamp Clamp Meter, 4 20 mA Multimeter, Model 771*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 771 delivers all the basic functionality you would expect in a milliamp clamp meter. It measures 4-20 mA signals without \"breaking the loop,\" allowing you to measure low level DC current without having to take systems offline for troubleshooting, saving downtime and money. You can also use it to measure output signals from transmitters without breaking the loop when maintaining and troubleshooting process and automation equipment. This saves time and avoids disrupting critical processes so you can avoid expensive downtime. You can also measure 10 to 50 mA signals in older control systems using the 99.9 mA range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned to make troubleshooting easier, the Fluke 771 includes a detachable clamp that can be attached to the wire you're testing while you move the meter—connected by the extension cable—to a better viewing position. This is especially helpful for taking readings in tight locations. With the dual backlit display showing both the mA measurement and the percent of a 4 to 20 mA span you can quickly understand what your system is doing, and a built-in LED spotlight lets you illuminate hard to see wire in dark enclosures. You can also capture and display changing measurements using the Hold function making it easier to verify and record measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures 4 to 20 mA signals without breaking the loop\u003c\/li\u003e\n\u003cli\u003eBest in class 0.2% accuracy\u003c\/li\u003e\n\u003cli\u003eDelivers 0.01 mA resolution and sensitivity\u003c\/li\u003e\n\u003cli\u003eMeasures mA signals for PLC and control system analog I\/O\u003c\/li\u003e\n\u003cli\u003eDetachable clamp for measurements in tight locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35%\"\u003eDiameter of measurable conductor\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.177 in or 4.5 mm max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-25 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 90% @ \u0026lt; 30°C, \u0026lt; 75% @ 30 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e59 x 38 x 212 mm (2.32 x 1.5 x 8.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e260 G, (9.1 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom 2 g, 5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 m drop test (except the jaw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eEMI\/RFI\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMeets EN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"small-font nobold\"\u003eFor current measurement w\/ JAW, add 1 mA to\u003cbr\u003especification for EMC field strengths of 1 V\/m up to 3 V\/m.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01% °C\u003cbr\u003e(\u0026lt; 18°C or \u0026gt; 28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower, battery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e(2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years for electronics\u003cbr\u003eOne year for cable and clamp assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eFunctional Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003emA measurement\u003cbr\u003e(measured by clamp)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 20.99 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \/ range\u003c\/td\u003e\n\u003ctd\u003e21.0mA to 100.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/771_data_sheet.pdf?v=1660239751\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122613353,"sku":"FLUFLUKE771","price":1450.39,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/771_c_nr-8795-1500x1000.png?v=1660239813"},{"product_id":"fluke-301d-ac-dc-clamp-meter","title":"Fluke 301D AC\/DC Clamp Meter","description":"\u003ch3\u003eGeneral Description\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 301D Series AC\/DC Clamp Meter is designed with a lightweight and compact body, which allows you to carry it around in your pocket. The slim and thin jaw can easily fit into tightly packed wires. The Fluke 301D test current, voltage, resistance, continuity, frequency (voltage and current), capacitance, and diode, etc.. You can handle multiple test needs with just one tool. With the AC\/DC function, it can be applied to more application scenarios requiring DC testing, such as new energy of PV and wind power, new energy vehicles, communications, data centers, etc..\u003cbr\u003e\u003cbr\u003eBenefits\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe body weighs only 154g and is 16mm thick, which is light and portable and can be put into a pocket\u003c\/li\u003e\n\u003cli\u003eThe slim and thin jaw of only 10mm can easily fit into tightly packed wires\u003c\/li\u003e\n\u003cli\u003e600A AC\/DC range (D model), 0.01A high resolution\u003c\/li\u003e\n\u003cli\u003eTests voltage, resistance and continuity\u003c\/li\u003e\n\u003cli\u003eTests current frequency and voltage frequency\u003c\/li\u003e\n\u003cli\u003eTests capacitance and diodes\u003c\/li\u003e\n\u003cli\u003eBacklight\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":53859096199540,"sku":"FLUFLUKE301D","price":223.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/Fluke301DACDCClampMeter3.webp?v=1769399674"}],"url":"https:\/\/orka.ca\/collections\/fluke-clamp-meters.oembed","provider":"Orka","version":"1.0","type":"link"}