{"title":"Black Friday 2026 Fluke","description":"\u003cp\u003eInput BF10 to enjoy 10% off on Fluke items\u003c\/p\u003e","products":[{"product_id":"fluke-true-rms-clamp-meter-fc-ac-dc-with-iflex-model-376-fc","title":"Fluke True-RMS Clamp Meter FC AC\/DC with iFlex, Model 376-FC","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.\u003c\/p\u003e\n\u003ch3\u003eFind the cause of difficult problems\u003c\/h3\u003e\n\u003cp\u003eThe 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.\u003cbr\u003e\u003cbr\u003eMeasure:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage to 1000 V AC or DC\u003c\/li\u003e\n\u003cli\u003eResistance to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e500 mV DC measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003cli\u003eWork safely and conveniently\u003c\/li\u003e\n\u003cli\u003eThe 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe included 18-inch or 36-inch iFlex flexible current probe provides easier access to large conductors in tight spaces. The flexible probe:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExpands the measurement range to 2500 A AC\u003c\/li\u003e\n\u003cli\u003eAllows frequency measurement to 500 Hz with body jaw and iFlex\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures AC\/DC current with included 18-inch or 36-inch iFlex current probe\u003c\/li\u003e\n\u003cli\u003eVFD low pass filter for accurate measurements of non-linear signals\u003c\/li\u003e\n\u003cli\u003eRemotely log, trend and monitor to pinpoint intermittent faults\u003c\/li\u003e\n\u003cli\u003eInrush measurement to filter out noise and capture starting current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable width=\"100%\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003eAC Current via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"4\"\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2% ±5 digits (10 Hz to 100 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e2.5% ±5 digits (100-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" colspan=\"4\"\u003eCrest Factor (50 Hz\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e3 @ 500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e2.5 @ 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eAC Current via Flexible Current Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"4\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.1 A (≤ 600 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e1 A (≤ 2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e3% ±5 digits (5 – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" colspan=\"4\"\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e3.0 at 1100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e2.5 at 1400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e1.42 at 2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cimg width=\"150\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/iflex-highres-cropped.png\" height=\"209\" alt=\"Flexible current probe\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ei2500-10 Flex\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003ei2500-18 Flex\u003c\/td\u003e\n\u003ctd\u003ei2500-36 Flex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e4.8 in (122.2 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.5 %\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±0.5 %\u003c\/td\u003e\n\u003ctd\u003e±0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003ctd\u003e5.3 in (133.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±1.0 %\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±1.0 %\u003c\/td\u003e\n\u003ctd\u003e±1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003ctd\u003e5.8 in (147.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±2.0 %\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±2.0 %\u003c\/td\u003e\n\u003ctd\u003e±2.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eDC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eAC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 V (≤600.0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1% ±5 digits (20 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eDC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 V (≤600.0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003emV dc\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e500.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eFrequency via Jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" colspan=\"2\"\u003eTrigger level \u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e5 Hz to 10 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e10 Hz to 100 Hz, ≥5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e100 Hz to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eFrequency via Flexible Current Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" colspan=\"2\"\u003eTrigger level \u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e5 Hz to 20 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e20 Hz to 100 Hz, ≥20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e100 Hz to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e60 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 Ω (≤600 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e1 Ω (≤6000 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e10 Ω (≤60 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0.1 μF (≤ 100 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e1 μ F (≤ 1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" colspan=\"2\"\u003eOperating humidity -\u003cbr\u003enon-condensing (\u0026lt; 10°C)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e≤90% RH (at 10 °C to 30 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e≤75% RH (at 30 °C to 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e≤45% RH (at 40 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e249 x 85 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e395 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eJaw opening\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFlexible current probe diameter\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFlexible current probe cable length\u003cbr\u003e(head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" colspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eIEC 61010-1, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eIEC 61010-2-033:CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRadio Frequency Certification FCC ID\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eT68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eElectromagnetic Compatibility (EMC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" colspan=\"2\"\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eCISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eClass A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTemperature coefficients\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374fc_user_manual.pdf?v=1660244557\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374_fc_datasheet.pdf?v=1660244557\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374_fc_brochure.PDF?v=1660244557\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120581737,"sku":"FLUFLUKE376FC","price":964.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-376fc-16a-1500x1000.png?v=1660245108"},{"product_id":"fluke-industrial-multimeterm-model-87-v","title":"Fluke Industrial Multimeterm, Model 87-V","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 87V Industrial Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment - even in loud, high-energy, and high-altitude locations. The 87V is designed so you can work more efficiently.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy-access door for fast battery changes without breaking the calibration seal\u003c\/li\u003e\n\u003cli\u003eAnalog bar graph for fast changing or unstable signals\u003c\/li\u003e\n\u003cli\u003eLarge digit display with bright, two-level backlight for easier reading in low light\u003c\/li\u003e\n\u003cli\u003eTouch Hold keeps readings on display even after removing probes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 87V lets you identify complex electrical problems fast. It supports accurate measurements on VFDs using a low-pass filter. The meter also captures intermittent as fast as 250 µS using Peak Capture. High-frequency, high-energy noise generated by large drive systems is blocked from your measurements with specially designed shielding.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAll the inputs in the 87V are updated to the third edition of the EN 61010-1 to CAT III 1000 V and CAT IV 600 V. The meter is designed to withstand spikes of more than 8000 V. You also benefit from an audible Input Alert warning if the test leads are placed in the incorrect input jacks for the measurement being made.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 87V has a removeable holster that also holds a test probe during testing for easier viewing. Relative mode lets you remove test lead resistance, improving accuracy of low-resistance measurements. To make your life even easier, the 87V fits into an optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIdentify complex signal problems fast\u003c\/li\u003e\n\u003cli\u003eSupports accurate measurements on VFDs using a low-pass filter\u003c\/li\u003e\n\u003cli\u003eCaptures intermittent as fast as 250 µS with Peak Capture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.05% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e10 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eVoltage AC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.7% + 2) True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC bandwidth\u003c\/td\u003e\n\u003ctd\u003e20 kHz with low pass filter; 3 dB @ 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A (20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent AC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A (20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 2) True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,999 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eaccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.005% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDuty cycle\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum duty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% per kHz + 0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e–200.0 °C – 1090 °C\u003cbr\u003e–328.0 °F – 1994.0 °F\u003cbr\u003eexcluding probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80 BK temperature probe\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e–40.0 °C – 260 °C\u003cbr\u003e–40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eConductance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum conductance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60.00 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDiode\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycle range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±(0.2% per kHz + 0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e–20 °C to + 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e–40 °C to + 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% – 90% (0 °C – 35 °C)\u003cbr\u003e0% – 70% (35 °C – 55 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61010–1 to 1000 V CAT III, 600V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCE, CSA, RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e201 x 98 x 52 mm (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e355 g\u003cbr\u003e624 g – with holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 counts updates 4\/sec.\u003cbr\u003e19,999 counts in high–resolution mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog\u003c\/td\u003e\n\u003ctd\u003e32 segments, updates 40\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e19,999 counts, updates 3\/sec at \u0026gt; 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAlkaline\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 Meter drop per IEC 61010–1:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePer MIL–PRF–28800 for a Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/87v_usermanual.pdf?v=1660239339\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/87v_quick_ref.pdf?v=1660239339\"\u003eQuick Reference\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120614505,"sku":"FLUFLUKE875","price":786.79,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F-87_V_01b_1500x1000_237aa03b-707b-4f48-9aeb-f3b30a6edd25.png?v=1660239516"},{"product_id":"fluke-non-contact-voltage-tester-model-1ac-ii","title":"Fluke Non-Contact Voltage Tester, Model 1AC-II","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe portable 1AC II non-contact voltage tester from Fluke are easy to use – just touch the tip to a terminal strip, outlet, or supply cord. When the tip glows red and the unit beeps, you know there's voltage present. Electricians, maintenance, service, safety personnel, and homeowners can quickly test for energized circuits in the workplace or at home and even detect miswires of an electrical outlet.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBe aware of voltage easily - the tip glows red and a beeper sounds when voltage is detected\u003c\/li\u003e\n\u003cli\u003eContinuous self-test so you always know it’s working\u003c\/li\u003e\n\u003cli\u003eVoltage detection range for wide application use - 90 V to 1000 V AC or 200 V to 1000 V AC\u003c\/li\u003e\n\u003cli\u003eAudible\/Silent mode for added convenience in quiet environments\u003c\/li\u003e\n\u003cli\u003eOn\/Off button\u003c\/li\u003e\n\u003cli\u003eBatteries included\u003c\/li\u003e\n\u003cli\u003e2 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Principles\u003c\/td\u003e\n\u003ctd\u003eSenses the steady state electrostatic ﬁeld produced by AC voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage sensing ranges\u003c\/td\u003e\n\u003ctd\u003eNominally, 90 V AC to 1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector tip style\u003c\/td\u003e\n\u003ctd\u003eFlat-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eOne high intensity red LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"safety-icon icon-CE\"\u003e‍\u003c\/span\u003e\u003cspan class=\"safety-icon icon-CSA C US\"\u003e‍\u003c\/span\u003e\u003cspan class=\"safety-icon icon-RCM\"\u003e‍\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1: Pollution Degree 2, IEC 61010-2-030: CAT IV 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C (-14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eOperating Humidity Ranges\u003c\/td\u003e\n\u003ctd\u003e0% to 95% (0°C to 30°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0% to 75% (30°C to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0% to 45% (40 to 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleaning\u003c\/td\u003e\n\u003ctd\u003eClean with damp cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e2 AAA alkaline batteries included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eTypical battery life of greater than 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty Period\u003c\/td\u003e\n\u003ctd\u003eTwo years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"2\"\u003eProduct does not respond to random electrostatic discharge.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/1acii_users_manual.pdf?v=1660240459\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120745577,"sku":"FLUFLUKE1ACA1II","price":54.73,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/1ac-II-voltage-tester.png?v=1660240475"},{"product_id":"fluke-multimeter-for-electricians-model-117","title":"Fluke Multimeter For Electricians, Model 117","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 117 Electricians Multimeter is a compact, CAT III 600 V, True-rms meter that includes an easy-to-use interface with a bright backlight for darker worksites. It saves you time and enables you to move from job to job more quickly. With a quick turn of the dial you can get measurements for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResistance\u003c\/li\u003e\n\u003cli\u003eContinuity\u003c\/li\u003e\n\u003cli\u003eFrequency\u003c\/li\u003e\n\u003cli\u003eCapacitance\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA digital multimeter designed to be hauled everywhere with you, part of your everyday tools. The 117 is built for demanding applications like:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial buildings\u003c\/li\u003e\n\u003cli\u003eHospitals\u003c\/li\u003e\n\u003cli\u003eSchools\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eKeep yourself safer with integrated VoltAlert™ technology. Fast, go\/no go non-contact voltage detection built into your multimeter saves you from having to carry around or find an extra tool to get the work started.\u003c\/p\u003e\n\u003cp\u003eSet the dial and get your measurement quickly with AutoVolt. This automatic AC\/DC voltage selector makes it easier for you to get the measurement you need and move on quicker.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the box:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 117 Digital Multimeter\u003c\/li\u003e\n\u003cli\u003e(1 pair) 4 mm silicone test lead set\u003c\/li\u003e\n\u003cli\u003eHolster\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact, true-rms digital multimeter for electricians\u003c\/li\u003e\n\u003cli\u003eIncludes multimeter, 4mm silicone test leads, holster and manual\u003c\/li\u003e\n\u003cli\u003eIntegrated non-contact voltage detection keeps you safe\u003c\/li\u003e\n\u003cli\u003ePrevent false readings from ghost voltage with selectable low-impedance mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Pollution Degree 2\u003cbr\u003eIEC 61010-2-033: CAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse for A input\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 A, 1000 V FAST Fuse (Fluke PN 803293)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDigital: 6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar graph\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9 volt Alkaline, IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC millivolts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.00 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAuto volts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e4.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC millivolts¹ True RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC volts¹ True RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eBeeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω detects opens or shorts of\u003cbr\u003e500 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eOhms\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e600.0 kΩ \/ 0.1 kΩ\u003cbr\u003e6.000 MΩ \/ 0.001 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/resolution\u003c\/td\u003e\n\u003ctd\u003e40.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.00 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF \/ 1 μF\u003cbr\u003e100 μF to 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/resolution\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLo-Z capacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 nF to 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10% + 2 typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC amps True RMS (45 Hz to 500 Hz)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 A \/ 0.001 A\u003cbr\u003e10.00 A \/ 0.01 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003cbr\u003e20 A continuous overload for 30 seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC amps\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6.000 A \/ 0.001 A   10.00 A \/ 0.01 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3\u003cbr\u003e20 A continuous overload for 30 seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHz (V or A input)²\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.9 Hz \/ 0.1 Hz\u003cbr\u003e9.999 kHz \/ 0.001 Hz\u003cbr\u003e50.00 kHz \/ 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"nobold small-font\"\u003e1. All AC voltage ranges except Auto-V\/LoZ are specified from 1% to 100% of range. Auto-V\/LoZ is specified from 0.0 V.\u003cbr\u003e2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.\u003cbr\u003e2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.\u003cbr\u003e2. Temperature Range\/Resolution: -40°F to 752°F \/ 0.2°F.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/117_user_manual_d7de60ef-c19d-4ace-bc7c-089545e287b8.pdf?v=1660240254\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120843881,"sku":"FLUFLUKE117","price":369.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F-117_03b_c_1500x1000_1.png?v=1660240309"},{"product_id":"fluke-mini-infrared-thermometer-model-62-max","title":"Fluke Mini Infrared Temperature Guage, Model 62-MAX","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 62 MAX Infrared temperature guage delivers many of the features of the Fluke 62 MAX+, but features a single laser and 10:1 distance to spot ratio. You can use the Fluke 62 MAX to perform non-contact temperature measurements on transformers, motors, pumps, panels, breakers, compressors, duct, steam lines, valves, and vents. It is small in size and extremely easy to use. The single laser helps you pinpoint the target for more accurate readings and makes it easier to measure temperatures in hard to reach areas. With its IP54 rating for dust and water resistance you can rely the Fluke 62 MAX to deliver accurate, repeatable temperature measurements, rain or shine, in even the dirtiest and dustiest industrial sites. And it’s rugged enough to take a 3-meter drop so no worries even if you work from a ladder.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHighly accurate infrared thermometer for measuring temperatures from -30°C to 500°C (-22°F to 932°F) accurate to +1.5°C or +1.5% of reading (whichever is greater)\u003c\/li\u003e\n\u003cli\u003eProvides a 10:1 Distance to spot ratio\u003c\/li\u003e\n\u003cli\u003eOffers single laser targeting for accurate and repeatable measurements\u003c\/li\u003e\n\u003cli\u003eFeatures IP54 rating against dust and moisture\u003c\/li\u003e\n\u003cli\u003eHigh and low alarms for rapid detection of temperatures outside the limits\u003c\/li\u003e\n\u003cli\u003ePowered by a single, standard AA battery.\u003c\/li\u003e\n\u003cli\u003eComes with a three-year warranty -30-\u003c\/li\u003e\n\u003cli\u003eWithstands a 3 m (9.8 ft.) drop\u003c\/li\u003e\n\u003cli\u003eOffers small, lightweight form factor to clip comfortably to your tool belt or belt loop, or easily fit in your tool box\u003c\/li\u003e\n\u003cli\u003eFeatures a large, backlit display to make data easier to read, even in dark areas.\u003c\/li\u003e\n\u003cli\u003eDisplays Min\/Max\/Avg\/Dif: the minimum, maximum or average temperature, or the difference between two measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-30°C to 500°C (-22°F to 932°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±1.5°C or ±1.5% of reading, whichever is greater\u003cbr\u003e-10°C to 0°C: ±2.0\u003cbr\u003e-30°C to -10°C: ±3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time (95%)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 500 ms (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral response\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 to 14 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.10 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10:1 (calculated at 90% energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C (0.2°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability of readings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.8% of reading or \u0026lt; ±1.0°C (2°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAA battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 hours with laser and backlight on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePhysical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e255 g (8.99 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 60°C (-4°F to 140°F), (without battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10% to 90% RH non-condensing at 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 54 per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration and shock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61326-1: Portable electromagnetic equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Pollution degree 2\u003cbr\u003eIEC 60825-1: Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/62_max_brochure_f41d5bd1-dce8-4c69-ba42-3da8e4872d00.pdf?v=1660240090\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/62max_user_manual.pdf?v=1660240089\"\u003eUser's manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120876649,"sku":"FLUFLUKE62MAX","price":166.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-62max_03b_1500x1000_096ded2b-ba57-47ee-ba98-384bc84eb521.png?v=1660240156"},{"product_id":"fluke-hvac-clamp-meters-true-rms-model-902-fc","title":"Fluke HVAC Clamp Meters, True-RMS, Model 902 FC*","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 902 FC Clamp Meter, with Fluke Connect wireless connectivity, can help HVAC technicians improve productivity in the field. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to perform many essential HVAC system measurements: microamps for testing pilot light sensors; resistance up to 60 kΩ; AC current and AC\/DC voltage; capacitance; and contact temperature, all with just one tool. Plus its small form factor makes it easy to hang on to and navigate in tight work spaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAs part of the Fluke Connect family, the 902 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. No need to write down the results. Trend and monitor measurements live on your phone screen, and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email, and collaborate in real time with other colleagues with ShareLive™ video calls or email.\u003c\/p\u003e\n\u003cp\u003eThe 902 FC can also decrease the frequency of wearing personal protective equipment (PPE) when working on high voltage\/current panels. Simply turn off the panel. Verify that it is de-energized using standard safety procedures. Place the clamp and synch it to a smartphone. Close the panel, reenergize it, and take measurements from a safe distance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the box:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e902 FC Clamp Meter\u003c\/li\u003e\n\u003cli\u003e(1 pair) TL75 test leads\u003c\/li\u003e\n\u003cli\u003e80BK integrated DMM temperature probe\u003c\/li\u003e\n\u003cli\u003e2 AA Alkaline Batteries (Installed)\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA wireless Fluke Connect®-enabled clamp meter designed specifically for the needs of HVAC technicians\u003c\/li\u003e\n\u003cli\u003eOffers 200 µA DC current measurements to measure flame rod\u003c\/li\u003e\n\u003cli\u003eExtends resistance range to measure thermistors up to 60kΩ\u003c\/li\u003e\n\u003cli\u003eCaptures flue gas temperature\u003c\/li\u003e\n\u003cli\u003eMeasures start and run motor capacitors\u003c\/li\u003e\n\u003cli\u003eMeasures variable frequency drive performance\u003c\/li\u003e\n\u003cli\u003eErgonomic design fits in your hand and can be used while wearing personal protective equipment\u003c\/li\u003e\n\u003cli\u003eLarge, easy-to-read backlit display improves readings in low light settings\u003c\/li\u003e\n\u003cli\u003eConnects to your smartphone via Fluke Connect so you can read measurements at a safer distance\u003c\/li\u003e\n\u003cli\u003eMeasures AC current to 600 A and AC and DC voltage to 600 V\u003c\/li\u003e\n\u003cli\u003eMeasures capacitance to 1000 µF and DC current to 200 µA\u003c\/li\u003e\n\u003cli\u003eMeasures temperature from -10 °C to 400 °C (14 °F to 752 °F)\u003c\/li\u003e\n\u003cli\u003eOffers True-RMS voltage and current measurements to accurately measure non-linear signals\u003c\/li\u003e\n\u003cli\u003eMeasures resistance to 60 kΩ\u003c\/li\u003e\n\u003cli\u003eOffers Min\/Max recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003eRuns on two AA alkaline batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFunction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eA ac (via Jaw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2.0% ±5 digit (45-65 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e2.5% ±5 digit (65-400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCrest Factor (50Hz or 60Hz)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003cspan\u003e \u003c\/span\u003eMIN@220\u003cspan\u003e \u003c\/span\u003eA\u003cbr\u003e\u0026gt; 1.4\u003cspan\u003e \u003c\/span\u003eMIN@600\u003cspan\u003e \u003c\/span\u003eA\u003cbr\u003eAdd 2% for CF\u0026gt;400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eV ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eV dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eOhms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1\/1\/10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600\/6000\/60.00 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1\/1 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e100.0\/1000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eµA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e200 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eContact temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 C\/F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% ±8 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-40 to 400 °C (-40 °F to 752 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eContinuity beeper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeeper volume\u003c\/td\u003e\n\u003ctd\u003e75 dBA nom. 15 cm. from case front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn threshold\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=30 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 AA alkaline batteries, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperating: -10 °C to +50 °C (14 °F to +122 °F)\u003cbr\u003eStorage: -40 °C to +60 °C (-40 °F to +140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNon condensing (\u0026lt; 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperating: 3,000 m (9,842 ft)\u003cbr\u003eStorage: 12,000 m (39,370 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (meter only)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e419 g (15 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1, Pollution Degree 2\u003cbr\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003cbr\u003eIEC 61010-2-033: CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Frequency Certification\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFCC ID:T68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInternational: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficients\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAdd 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/902_user_manual.pdf?v=1660236147\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120909417,"sku":"FLUFLUKE902FC","price":499.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/902-fc-hvac_clamp-meter-1500x1000.png?v=1660236186"},{"product_id":"fluke-true-rms-clamp-multimeter-model-325","title":"Fluke True-RMS Clamp Multimeter, Model 325*","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 325 True-rms Clamp Meter is a reliable, versatile troubleshooting tool for commercial and residential electricians. Featuring a slim design for easy transport and use, and a large display for efficient troubleshooting. In addition to true-rms AC current and voltage on non-linear loads, the 325 measures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDC current\u003c\/li\u003e\n\u003cli\u003eDC voltage\u003c\/li\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eFrequency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou’ll carry fewer tools in your bag and get more work done.\u003c\/p\u003e\n\u003cp\u003eThe 325 gives you a strong combination of measurement functions, in a tool that is reliable, easy-to-use and affordable. This clamp meter offers True-rms AC voltage and current measurements on non-linear signals. Paired with the CAT III 600 V, CAT IV 300 V safety rating the clamp meter can also measure:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures AC\/DC current up to 400 A through jaw\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage to 600 V using test leads\u003c\/li\u003e\n\u003cli\u003eMeasures frequency from 5 Hz to 500 Hz; resistance to 40 kΩ\u003c\/li\u003e\n\u003cli\u003eMeasures temperature from -10 °C to 400 °C with included K-type thermocouple\u003c\/li\u003e\n\u003cli\u003eMin\/Max function records important values\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eComes with a two-year warranty\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-rms AC\/DC current, voltage, temperature, frequency\u003c\/li\u003e\n\u003cli\u003eClamp meter, test leads, K-type thermocouple and soft case\u003c\/li\u003e\n\u003cli\u003eVersatile tool performs most front-line measurement tasks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" rowspan=\"2\"\u003eAC current\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e40.00 A \/ 400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% ± 5 digits (45 Hz to 65 Hz)\u003cbr\u003e2.5% ± 5 digits (65 Hz to 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e40.00 A \/ 400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω \/ 4000 Ω \/ 40.00 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤ 30 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e0 to 100.0 μF \/ 100μF to 1000 μF\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAC response\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContact temperature\u003c\/td\u003e\n\u003ctd\u003e-10.0°C to 400.0°C (14.0°F to 752.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMin\/Max\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eH x W x D (mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e207 x 75 x 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax wire diameter\u003c\/td\u003e\n\u003ctd\u003e30 mm (600 MCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e283 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCategory rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003cbr\u003eCAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eTwo-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_user_manual.pdf?v=1660246448\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_quick_reference.pdf?v=1660246448\"\u003eQuick Reference\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_brochure.PDF?v=1660246448\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213120974953,"sku":"FLUFLUKE325","price":613.19,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-325-01c-1500x1000.png?v=1660246490"},{"product_id":"fluke-true-rms-digital-multimeter-with-non-contact-voltage-detection-model-177","title":"Fluke True-RMS Digital Multimeter with Non-Contact Voltage Detection, Model 177*","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eWith its precision, reliability, and ease of use, the Fluke 177 Digital Multimeter is the preferred solution for professional technicians worldwide. Independently tested for safe use in CAT IV 600 V\/CAT III 1000 V environments, the Fluke 177 Includes all the features you need to troubleshoot and repair many problems in electrical and electronic systems.\u003c\/p\u003e\n\u003cp\u003eWith the Fluke 177 Digital Multimeter you get True-RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging, and frequency, capacitance, resistance, continuity, and diode measurements. In addition, the Fluke 177 provides 0.09% basic accuracy, a digital display with analog bar graph and backlight. Plus a limited lifetime warranty.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-RMS digital multimeter with the features professional technicians prefer\u003c\/li\u003e\n\u003cli\u003eIncreases productivity with manual and automatic ranging, Display Hold, Auto Hold, and Min\/Max-average recording\u003c\/li\u003e\n\u003cli\u003eMeasures AC and DC voltage to 1000 V\u003c\/li\u003e\n\u003cli\u003eDelivers accurate True-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements\u003c\/li\u003e\n\u003cli\u003eSafety rated CAT III 1000 V, CAT IV 600 V\u003c\/li\u003e\n\u003cli\u003eFeatures digital display with backlight for working in dim lighting\u003c\/li\u003e\n\u003cli\u003eAllows closed case calibration through front panel\u003c\/li\u003e\n\u003cli\u003eFeatures an ergonomic case with integrated protective holster\u003c\/li\u003e\n\u003cli\u003eComes with a limited lifetime warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"3\" data-mce-fragment=\"1\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"3\" data-mce-fragment=\"1\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAccuracy\u003csup data-mce-fragment=\"1\"\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMax. resolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"3\" data-mce-fragment=\"1\"\u003eVoltage AC\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAccuracy\u003csup data-mce-fragment=\"1\"\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±(1.0% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMax. resolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"3\" data-mce-fragment=\"1\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAccuracy\u003csup data-mce-fragment=\"1\"\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±(1.0% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMax. resolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"3\" data-mce-fragment=\"1\"\u003eCurrent AC\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAccuracy\u003csup data-mce-fragment=\"1\"\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMax. resolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"3\" data-mce-fragment=\"1\"\u003eResistance\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAccuracy\u003csup data-mce-fragment=\"1\"\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±(0.9% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMax. resolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"3\" data-mce-fragment=\"1\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAccuracy\u003csup data-mce-fragment=\"1\"\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±(1.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMax. resolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e10,000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"3\" data-mce-fragment=\"1\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eAccuracy\u003csup data-mce-fragment=\"1\"\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eMax. resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"unbold small-font\" colspan=\"3\" data-mce-fragment=\"1\"\u003e1. Accuracies are best accuracies for each function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\" data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"3\" data-mce-fragment=\"1\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e-30°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e0% – 90% (0°C – 35°C)\u003cbr data-mce-fragment=\"1\"\u003e0% – 70% (35°C – 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\" data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"3\" data-mce-fragment=\"1\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eEN 61010–1 to 1000 V CAT III\u003cbr data-mce-fragment=\"1\"\u003eEN 61010–1 to 600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eUL, CSA, TÜV listed and VDE Pending\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\" data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"3\" data-mce-fragment=\"1\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e43 x 90 x 185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003e420 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eLifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eAlkaline ~200 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/177_user_manual.pdf?v=1660321034\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121106025,"sku":"FLUFLUKE177ESFP","price":670.59,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F-177_01c_1500x1000_69d8ec04-c387-48c9-a921-6dadb14a0501.png?v=1660320835"},{"product_id":"fluke-hvac-combo-kit-includes-multimeter-and-clamp-meter-model-116-323-kit","title":"Fluke HVAC Combo Kit - Includes Multimeter and Clamp Meter, Model 116\/323-KIT*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eHaving the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 116\/323 HVAC Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe; no need to carry a separate thermometer. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV\/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min\/Max\/Average readings with elapsed time to record signal fluctuations.\u003c\/p\u003e\n\u003cp\u003eFluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.\u003c\/p\u003e\n\u003cp\u003eTrue RMS measurements and optimized ergonomics make the Fluke 323 True RMS Clamp Meter the best general purpose clamp meter for commercial and residential electricians. The Fluke 323 model is ideally suited for current measurements up to 400 A in tight cable compartments.\u003c\/p\u003e\n\u003cp\u003eTogether, the Fluke 116 HVAC Multimeter and 323 True RMS Clamp Meter give electricians the right tools for the job.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 116 Digital Multimeter. Designed by Electricians. Engineered by Fluke.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in thermometer for HVAC applications\u003c\/li\u003e\n\u003cli\u003eMicroamps to test flame sensors\u003c\/li\u003e\n\u003cli\u003eLow input impedance: helps prevent false readings due to ghost voltage\u003c\/li\u003e\n\u003cli\u003eLarge white LED backlight to work in poorly lit areas\u003c\/li\u003e\n\u003cli\u003eResistance, continuity, frequency and capacitance\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average with elapsed time to record signal fluctuations\u003c\/li\u003e\n\u003cli\u003eCompact ergonomic design for one-handed operation\u003c\/li\u003e\n\u003cli\u003eCompatible with optional magnetic hanger (ToolPak™)\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 323 True-rms Clamp Meter. Rugged. Reliable. Precise.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e400 A AC current measurement\u003c\/li\u003e\n\u003cli\u003e600 VAC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue RMS AC voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eResistance measurement up to 40 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eSlim, ergonomic design\u003c\/li\u003e\n\u003cli\u003eCAT IV 300 V\/CAT III 600 V safety rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e116 Technical Information \u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar graph\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9 volt Alkaline, NEDA 1604A\/ IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC millivolts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.00 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAuto volts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e4.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC millivolts¹ True RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC volts¹ True RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eBeeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω; detects opens or shorts of 500 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eOhms\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e600.0 kΩ \/ 0.1 kΩ\u003cbr\u003e6.000 MΩ \/ 0.001 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e40.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.000 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF \/ 1 μF\u003cbr\u003e100 μF to 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLoZ capacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 nF to 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10% + 2 typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTemperature² (Type-K thermocouple)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 400°C \/ 0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 10²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e-40°F to 752°F \/ 0.2°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 18²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC μamps True RMS (45 Hz to 500 Hz)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 μA \/ 0.1 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC μamps\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 μA \/ 0.1 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHz (V or A input)²\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.99 Hz \/ 0.1 Hz\u003cbr\u003e9.999 Hz \/ 0.001 Hz\u003cbr\u003e50.00 Hz \/ 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"nobold small-font\"\u003e1. All AC voltage ranges except Auto-V\/LoZ are specified from 1% to 100% of range. Auto-V\/LoZ is specified from 0.0 V.\u003cbr\u003e2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.\u003cbr\u003e• Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.\u003cbr\u003e• Temperature Range\/Resolution: -40°F to 752°F \/ 0.2°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e323 Technical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% ±5 digits\u003cbr\u003e(45 Hz to 65 Hz)\u003cbr\u003e2.5% ±5 digits\u003cbr\u003e(65 Hz to 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω\/ 4000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤ 70 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAC response\u003c\/td\u003e\n\u003ctd\u003eTrue-rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eH x W x D (mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e207 x 75 x 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax wire diameter\u003c\/td\u003e\n\u003ctd\u003e30 mm (600 MCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e265 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCAT III 600 V\u003cbr\u003eCAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTwo-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/323_user_manual.pdf?v=1660158261\"\u003e323 User's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/323_quic_ref.pdf?v=1660158261\"\u003e323 Quick Reference\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/323_brochure.PDF?v=1660158261\"\u003e323 Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/116_quick_ref.pdf?v=1660236378\"\u003e116 Quick Reference\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/116_user_manual.pdf?v=1660236404\"\u003e116 User's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121171561,"sku":"FLUFLUKE116323KIT","price":547.37,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/116-323-kit_300dpi_454x308mm_c_nr-15513-1500x1000.png?v=1660236453"},{"product_id":"fluke-true-rms-digital-multimeter-model-115","title":"Fluke True-RMS Digital Multimeter, Model 115*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 115 field technician’s digital multimeter measures True-rms voltage and current with plus resistance, continuity, frequency, and capacitance to meet the needs of a wide variety of field service technicians.\u003c\/p\u003e\n\u003cp\u003eThe 115 digital multimeter offers the users one-handed operation and a backlit display. The large, easy-to-read digits offer a 6000-count resolution. The 115 provides Min\/Max\/Average with elapsed time to record signal fluctuations. It also measures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC and DC voltage to 600V,\u003c\/li\u003e\n\u003cli\u003eAC and DC current to 10 A (20 A overload for 30-seconds max).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact True-rms digital multimeter for field service\u003c\/li\u003e\n\u003cli\u003eIncludes: meter, holster, 4 mm PVC-Insulated test lead\u003c\/li\u003e\n\u003cli\u003eEasy one-handed operation of the meter\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average to record signal fluctuations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC millivolts\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e± ([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.00 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e± ([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC millivolts\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC volts\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eBeeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω detects opens or shorts of\u003cbr\u003e500 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eOhms\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e600.0 kΩ \/ 0.1 kΩ\u003cbr\u003e6.000 MΩ \/ 0.001 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/resolution\u003c\/td\u003e\n\u003ctd\u003e40.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.00 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF \/ 1 μF\u003cbr\u003e100 μF to 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/resolution\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLo-Z capacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 nF to 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10% + 2 typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC amps True RMS\u003cbr\u003e(45 Hz to 500Hz)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 A \/ 0.001 A\u003cbr\u003e10.00 A \/ 0.01 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003cbr\u003e20 A overload for 30-seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC amps\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 A \/ 0.001 A\u003cbr\u003e10.00 A \/ 0.01 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3\u003cbr\u003e20 A overload for 30-seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHz (V or A input)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.9 Hz \/ 0.01 Hz\u003cbr\u003e9.999 kHz \/ 0.001 kHz\u003cbr\u003e50.00 kHz \/ 0.01 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"nobold small-font\"\u003e1. All AC voltage ranges except Auto-V\/LoZ are specified from 1% to 100% of range. Auto-V\/LoZ is specified from 0.0 V.\u003cbr\u003e2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.\u003cbr\u003e2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.\u003cbr\u003e2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.\u003cbr\u003e2. Temperature Range\/Resolution: -40℉ to 752℉ \/ 0.2℉.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1: Pollution Degree 2\u003cbr\u003eIEC 61010-2-033: CAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDigital: 6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar graph\u003c\/td\u003e\n\u003ctd\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10℃ to + 50℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40℃ to + 60℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003e9 volt Alkaline, IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e550 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/117_user_manual.pdf?v=1660061399\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121269865,"sku":"FLUFLUKE115","price":342.37,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/115_300dpi_249x349mm_c_nr-12396-1500x1000.png?v=1660320672"},{"product_id":"fluke-true-rms-digital-clamp-meter-model-323","title":"Fluke True-RMS Digital Clamp Meter, Model 323","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 323 clamp meter is a good basic troubleshooting tool for commercial and residential electricians. It includes True RMS measurements, optimized ergonomics, and large display for efficient troubleshooting. It's designed to perform in the toughest environments and provide noise-free, reliable results, so you can trust it to help you confidently diagnose problems almost anywhere. Use it to verify the presence of load current, AC voltage, and continuity of circuits, switches, fuses and contacts. Its slim, compact size and rugged design make it well suited for measuring current up to 400 A in tight cable compartments.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 323 comes with a two-year warranty and a soft carrying case.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, reliable basic True-RMS clamp meter for measuring current up to 400 A\u003c\/li\u003e\n\u003cli\u003eMeasures AC current to 400 A\u003c\/li\u003e\n\u003cli\u003eMeasures AC voltage and DC voltage to 600 V\u003c\/li\u003e\n\u003cli\u003eProvides True RMS AC voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eMeasures resistance to 4 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eFeatures slim, ergonomic design for measuring in tight cable compartments\u003c\/li\u003e\n\u003cli\u003ePresents measurements on a large, easy-to-read display\u003c\/li\u003e\n\u003cli\u003eHold function captures a reading on the display\u003c\/li\u003e\n\u003cli\u003eFeatures a CAT III 600 V, CAT IV 300 V safety rating\u003c\/li\u003e\n\u003cli\u003eComes with a two-year warranty and soft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" rowspan=\"2\"\u003eAC current\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% ± 5 digits (45 Hz to 65 Hz)\u003cbr\u003e2.5% ± 5 digits (65 Hz to 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω\/ 4000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤ 70 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAC response\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContact temperature\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMin\/Max\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eH x W x D (mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e207 x 75 x 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax wire diameter\u003c\/td\u003e\n\u003ctd\u003e30 mm (600 MCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e265 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCategory rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003cbr\u003eCAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eTwo-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_user_manual.pdf?v=1660246448\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_user_manual.pdf?v=1660246448\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_quick_reference.pdf?v=1660246448\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_quick_reference.pdf?v=1660246448\"\u003eQuick Reference\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_brochure.PDF?v=1660246448\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/325_brochure.PDF?v=1660246448\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121400937,"sku":"FLUFLUKE323","price":291.19,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-323-01c-1500x1000_1.png?v=1660247597"},{"product_id":"fluke-true-rms-ac-dc-clamp-meter-model-375-fc","title":"Fluke True-RMS AC\/DC Clamp Meter, Model 375-FC*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 375 FC, part of the Fluke Connect family of wireless test tools, delivers high performance features and ease of use. It features a VFD low-pass filter for accurate motor drive measurements and wireless communications to transmit results to a smartphone via Fluke Connect\u003c\/p\u003e\n\u003cp\u003eThe 375 FC offers most of the features of the Fluke 376 FC including compatibility with the iFlex flexible current probe but, unlike the 376 FC, it does not include the iFlex® probe in the package. You can measure AC and DC current to 600 A and voltage up to 1000 V with the fixed jaw clamp. Or connect an optional iFlex® flexible current probe to expand your measurement range to 2500 A AC. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access individual wires.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUsing its Bluetooth connectivity to Apple and Android devices, you can read the 375 FC results a safe distance away on your smartphone, wearing less PPE. You can create and send reports in email right from the field and save results to the cloud. You can also converse with colleagues in real-time with ShareLive™ video calls.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith True-RMS AC voltage and current measurements, the 375 enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 375 FC Clamp Meter is the direct replacement for the Fluke 375 Clamp Meter.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance clamp meter that measures very low voltage and high resistance\u003c\/li\u003e\n\u003cli\u003eTransmits measurements to your smartphone via Fluke Connect® so you can view them at a safer distance\u003c\/li\u003e\n\u003cli\u003eMeasures AC and DC current to 600 A, and AC and DC voltage to 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasures AC current to 2500 A AC with optional iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003eCompatible with optional TPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eComes with batteries, soft carrying case, and three-year warranty\u003c\/li\u003e\n\u003cli\u003eFeatures CAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eMeasures capacitance to 1000 µF\u003c\/li\u003e\n\u003cli\u003eIncludes True-RMS voltage and current measurements to accurately measure non-linear signals\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 500 Hz and resistance to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eIncludes Min\/Max\/Avg and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003eOffers 500 mV DC measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli\u003eRuns on two AA alkaline batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAC Current via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% ±5 digits (10 Hz to 100 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e2.5% ±5 digits (100-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCrest Factor (50 Hz\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 @ 500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e2.5 @ 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC Current via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A (≤ 600 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 A (≤ 2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3% ±5 digits (5 – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.0 at 1100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e2.5 at 1400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1.42 at 2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePosition Sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cspan\u003e\u003cimg alt=\"Flexible current probe\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/37x_position_sens_100x181.png\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-10 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-18 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd\u003e±0.5 %\u003c\/td\u003e\n\u003ctd\u003e±0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd\u003e±1.0 %\u003c\/td\u003e\n\u003ctd\u003e±1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd\u003e±2.0 %\u003c\/td\u003e\n\u003ctd\u003e±2.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 V (≤600.0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% ±5 digits (20 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 V (≤600.0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003emV dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTrigger level \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 Hz to 10 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e10 Hz to 100 Hz, ≥5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTrigger level \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 Hz to 20 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e20 Hz to 100 Hz, ≥20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e100 Hz to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e60 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Ω (≤600 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 Ω (≤6000 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e10 Ω (≤60 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 μF (≤ 100 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 μ F (≤ 1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eOperating humidity -\u003cbr\u003enon-condensing (\u0026lt; 10°C)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≤90% RH (at 10 °C to 30 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e≤75% RH (at 30 °C to 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e249 x 85 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e395 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe diameter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe cable length\u003cbr\u003e(head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Frequency Certification FCC ID\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eT68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eCISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eClass A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficients\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374fc_user_manual.pdf?v=1660244557\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374_fc_datasheet.pdf?v=1660244557\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374_fc_brochure.PDF?v=1660244557\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121433705,"sku":"FLUFLUKE375FC","price":852.59,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-375fc-01a-1500x1000.png?v=1660244900"},{"product_id":"fluke-true-rms-digital-multimeter-model-179","title":"Fluke True-RMS Digital Multimeter, Model 179","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 179 True-rms Digital Multimeter is the industry-standard troubleshooting tool for electrical and electronic systems. This incredibly versatile multimeter makes a perfect front-line troubleshooting tool with an input protection rating of CAT III 1000 V, CAT IV 600 V. The built-in temperature measurement with the included thermocouple, analog bar graph and backlit digital display make it easier to take the measurements you need.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA full set of basic and advanced troubleshooting capabilities including:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManual and automatic ranging\u003c\/li\u003e\n\u003cli\u003eDisplay Hold and Auto Hold\u003c\/li\u003e\n\u003cli\u003eMin\/Max-Average recording\u003c\/li\u003e\n\u003cli\u003eVoltage measurements to 1000 V AC or DC\u003c\/li\u003e\n\u003cli\u003eCurrent measurements to 10 A AC\/DC\u003c\/li\u003e\n\u003cli\u003eResistance to 50 MΩ; capacitance to 10,000 μF, frequency to 100 kHz; temperature from -40 ℃ to 400 ℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll of these features come paired with a lifetime warranty.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1000V AC\/DC; 10A AC\/DC (with test leads and current jacks); resistance to 50 MΩ; capacitance to 10,000 μF, frequency to 100 kHz; temperature from -40 ℃ to 400 ℃\u003c\/li\u003e\n\u003cli\u003eRobust, fast and accurate with manual and automatic ranging, Display Hold, Auto Hold, and Min\/Max-Average recording\u003c\/li\u003e\n\u003cli\u003eBacklit digital display, analog bar graph, and built-in temperature measurements with included thermocouple.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.9% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e1 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e10,000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMax. resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-40°C \/ 400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"small-font nobold\"\u003e1. Accuracies are best accuracies for each function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-30°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% – 90% (0°C – 35°C)\u003cbr\u003e0% – 70% (35°C – 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61010–1 to 1000 V CAT III\u003cbr\u003eEN 61010–1 to 600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUL, CSA, TÜV listed and VDE Pending\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e43 x 90 x 185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e420 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAlkaline ~200 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/177_user_manual.pdf?v=1660321034\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121532009,"sku":"FLUFLUKE179ESFP","price":713.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F-179_01e_1500x1000_78200c6c-b556-465a-bbe8-0b29536dd290.png?v=1660323791"},{"product_id":"fluke-true-rms-digital-multimeter-model-175","title":"Fluke True-RMS Digital Multimeter, Model 175*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 175 True RMS Digital Multimeter delivers the baseline general purpose features required by professional technicians around the world. You can find problems fast with all the basic troubleshooting measurements such as frequency, capacitance, resistance, continuity, and diode. And Display Hold and Auto Hold will help you capture significant events.\u003c\/p\u003e\n\u003cp\u003eAll inputs on the 175 are protected to IEN61010-1 CAT IV 600 V\/CAT III 1000 V. UL, CSA, TÜV listed and VDE Pending. You can rely on the Fluke 175 for accurate, true-RMS readings through years of reliable service.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides the baseline multimeter features you need for troubleshooting and repairing electrical and electronic systems\u003c\/li\u003e\n\u003cli\u003eDelivers accurate true-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements\u003c\/li\u003e\n\u003cli\u003eIncreases productivity with manual and automatic ranging, Display Hold, Auto Hold, and Min\/Max-average recording\u003c\/li\u003e\n\u003cli\u003eSafety rated CAT III 1000 V, CAT IV 600 V\u003c\/li\u003e\n\u003cli\u003eComes with a lifetime warranty\u003c\/li\u003e\n\u003cli\u003eAllows closed-case calibration through front panel\u003c\/li\u003e\n\u003cli\u003eIncludes ergonomic case with integrated protective holster\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.15% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.9% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e1 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e10,000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMax. resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"unbold small-font\"\u003e1. Accuracies are best accuracies for each function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-30°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% – 90% (0°C – 35°C)\u003cbr\u003e0% – 70% (35°C – 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61010–1 to 1000 V CAT III\u003cbr\u003eEN 61010–1 to 600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUL, CSA, TÜV listed and VDE Pending\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e43 x 90 x 185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e420 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAlkaline ~200 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/177_user_manual.pdf?v=1660321034\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121564777,"sku":"FLUFLUKE175ESFP","price":617.39,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/fluke-175-multimeter_300dpi_251x350mm-1500x1000.png?v=1660323703"},{"product_id":"fluke-toolpak™-magnetic-meter-hanger-model-tpak","title":"Fluke ToolPak™ Magnetic Meter Hanger, Model TPAK","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke TPAK ToolPak™ Magnetic Meter Hanger allows you to hang your meter on nails, hooks, and pipes so you can take hands-free measurements. Always demand the best; use the original TPAK Meter hanging kit with its unique rare-earth magnet for superior gripping strength to ensure your tools don’t slide or fall.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHang your meter in a variety of ways for convenient hands-free operation, solve any hanging and positioning problems you may face. Use the hook and loop strap to wrap around a pole or pipe and hang your meter. Use the magnet to throw your meter on a panel door while you work the test leads to take a measurement quickly and safely.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the box:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e9-inch hook and loop strap\u003c\/li\u003e\n\u003cli\u003eTapered hook and loop strap\u003c\/li\u003e\n\u003cli\u003eUniversal hanger clip\u003c\/li\u003e\n\u003cli\u003eHook hanger for non-magnetic surfaces\u003c\/li\u003e\n\u003cli\u003eStrong magnet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStrong, rare-earth magnet hanger strap with Fluke durability \u003c\/li\u003e\n\u003cli\u003eHang with magnet or hook strap for non-magnetic surfaces\u003c\/li\u003e\n\u003cli\u003eSolves any hanging and positioning problem you may face\u003c\/li\u003e\n\u003cli\u003eEasily work hands-free\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/tpak_datasheet.pdf?v=1660244145\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121728617,"sku":"FLUTPAK","price":74.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/tpak-magnetic-hanger.png?v=1660244118"},{"product_id":"fluke-handheld-ir-laser-thermometer-model-62max","title":"Fluke Handheld IR Laser Thermo Meter, Model 62Max+*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 62 MAX+ Handheld Infrared Laser Thermo Meter delivers the accuracy you need in an extremely rugged package. Just point, shoot, and read the temperature of many types of equipment. Get accurate readings form transformers, motors, pumps, panels, breakers, compressors, duct, steam lines, valves, and vents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy to use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IR thermometer’s small size and versatile features make it extremely easy to use. Plus, the lightweight form factor clips comfortably to your tool belt or belt loop, or easily fits in your toolbox. The 62 MAX+ offers a wide variety of features to take measurements quickly:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh and low alarms for rapid detection of measurements outside the limits\u003c\/li\u003e\n\u003cli\u003eDisplays Min\/Max\/Avg\/Dif\u003c\/li\u003e\n\u003cli\u003eThe minimum, maximum or average temperature, or the difference between two measurements\u003c\/li\u003e\n\u003cli\u003eEasy to read, even in dark areas with large, backlit display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWorks every place you need to go\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 62 MAX+ is rugged enough to take a three-meter drop – good news if you work from a ladder. Dual lasers help you target your measurement; the 12:1 distance to spot ratio helps get the reading you want. With its IP54 rating for dust and water resistance you can rely the Fluke 62 MAX+ to provide extremely accurate temperature measurements, rain or shine, even in dirty and dusty industrial sites.\u003c\/p\u003e\n\u003cp\u003ePowered by a single, standard AA battery.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely rugged – 3-meter drop tested, IP54 for dust and moisture\u003c\/li\u003e\n\u003cli\u003ePrecise dual-lasers for more accurate, repeatable measurements\u003c\/li\u003e\n\u003cli\u003eProvides up to a 12:1 Distance to spot ratio\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-30°C to 650°C (-22°F to 1202°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±1.0°C or ±1.0% of reading, whichever is greater\u003cbr\u003e-10°C to 0°C: ±2.0\u003cbr\u003e-30°C to -10°C: ±3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time (95%)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 500 ms (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral response\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 to 14 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.10 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12:1 (calculated at 90% energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C (0.2°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability of readings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.5% of reading or \u0026lt;±0.5°C (1°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAA battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 hours with laser and backlight on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePhysical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e255 g (8.99 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 60°C (-4°F to 140°F), (without battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10% to 90% RH non-condensing at 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 54 per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration and shock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61326-1: Portable electromagnetic equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Pollution degree 2\u003cbr\u003eIEC 60825-1: Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/62max_usermanual.pdf?v=1660161044\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/62_max_brochure.pdf?v=1660161044\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121794153,"sku":"FLUFLUKE62MAX+","price":314.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/62-max-plus-01b-1500x1000.png?v=1660235062"},{"product_id":"fluke-true-rms-ac-dc-clamp-meter-model-374-fc","title":"Fluke True-RMS AC\/DC Clamp Meter, Model 374 FC*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 374 FC, part of the Fluke Connect family of wireless test tools, delivers the standard features you need for everyday troubleshooting. Measure AC and DC current to 600 A with the fixed jaw clamp or add an optional iFlex® flexible current probe to measure all the way to 2500 A. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access tightly packed wires. You can also use the 374 FC to measure AC and DC voltage to 1000 V and resistance to 6000 Ω.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 374 FC is Fluke Connect-enabled to wirelessly transmit results via Bluetooth to Apple and Android devices. That means you can read the results out of the arc flash zone, wearing less PPE. You can even save results to the cloud and create and send reports in email right from the field. Or converse in real-time with ShareLive™ video calls.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith True-RMS AC voltage and current measurements, the 374 FC enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 374 FC Clamp Meter is the direct replacement for the Fluke 374 Clamp Meter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the box:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e374 FC AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003e(1 pair) TL75 test leads\u003c\/li\u003e\n\u003cli\u003eTwo AA Alkaline batteries (Installed)\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced clamp meter that transmits measurements to your smartphone via Fluke Connect® for viewing at a safer distance\u003c\/li\u003e\n\u003cli\u003ePerforms AC and DC current measurements to 600 A, and AC and DC voltage measurements to 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasures AC current to 2500 A AC with optional iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003eMeasures resistance to 6000 Ω with continuity detection\u003c\/li\u003e\n\u003cli\u003eCompatible with optional TPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eComes with soft carrying case, batteries, and three-year warranty\u003c\/li\u003e\n\u003cli\u003eMeasures capacitance to 1000 µF\u003c\/li\u003e\n\u003cli\u003eFeatures CAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eProvides True-RMS voltage and current measurements to accurately measure non-linear signals\u003c\/li\u003e\n\u003cli\u003eIncludes Min\/Max\/Avg and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003eRuns on two AA alkaline batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eAC Current via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2% ±5 digits (10 Hz to 100 Hz)\u003cbr\u003e2.5% ±5 digits (100-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50 Hz\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.5 @ 600 A\u003cbr\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Current via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A (≤ 600 A)\u003cbr\u003e1 A (≤ 2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3% ±5 digits (5 – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.5 at 1400 A\u003cbr\u003e1.42 at 2500 A\u003cbr\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003ePosition Sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/37x_position_sens_100x181.png\" alt=\"Flexible current probe\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cb\u003eDistance from Optimum\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-10 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-18 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eError\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e±0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eB\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003ctd\u003e±1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003ctd\u003e±2.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" class=\"small-font nobold\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V (≤600.0 V)\u003cbr\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.5% ±5 digits (20 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V (≤600.0 V)\u003cbr\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003emV dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e500.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Ω (≤600 Ω)\u003cbr\u003e1 Ω (≤6000 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 μF (≤ 100 μF)\u003cbr\u003e1 μ F (≤ 1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMechanical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity -\u003cbr\u003enon-condensing (\u0026lt; 10°C)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤90% RH (at 10 °C to 30 °C)\u003cbr\u003e≤75% RH (at 30 °C to 40 °C)\u003cbr\u003e≤45% RH (at 40 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e249 x 85 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e395 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe diameter\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe cable length\u003cbr\u003e(head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 61010-1, Pollution Degree 2\u003cbr\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003cbr\u003eIEC 61010-2-033:CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Frequency Certification FCC ID\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eT68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2\u003cbr\u003eCISPR 11: Group 1, Class A\u003cbr\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003cbr\u003eClass A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003cbr\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficients\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374fc_user_manual.pdf?v=1660244557\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374_fc_datasheet.pdf?v=1660244557\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/374_fc_brochure.PDF?v=1660244557\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121826921,"sku":"FLUFLUKE374FC","price":779.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-374fc-05a-1500x1000.png?v=1660244625"},{"product_id":"fluke-large-soft-carrying-case-model-c25","title":"Fluke Large Soft Carrying Case, Model C25","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eGive your Fluke tools the protection they deserve. You bought the best, why not protect them with Fluke cases. The C25 carrying case is a durable, zippered carrying case with padding and inside pocket, and high quality polyester exterior. It includes a convenient hand strap and carries most of Fluke’s popular digital multimeters. Our most popular case sold to date! Now available in standard and camouflage designs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZippered carrying case with padding and inside pocket.\u003c\/li\u003e\n\u003cli\u003eOne year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e218 x 128 x 64 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e8.6 x 5 x 2.52 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213121925225,"sku":"FLUC25","price":74.69,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/C25-multimeter-case.png?v=1660239641"},{"product_id":"fluke-suregrip™-industrial-test-lead-set-model-tl220","title":"Fluke SureGrip™ Industrial Test Lead Set, Model TL220","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe TL220, SureGrip™ Industrial Test Lead Set is designed to provide a reliable grip in slippery hands. With interchangeable test lead set for multiple electrical applications. Compatible with all instruments and test probes that accept standard 4 mm shrouded banana connectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis handy all-in-one kit includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC220 SureGrip\u003c\/li\u003e\n\u003cli\u003eAlligator Clip Set\u003c\/li\u003e\n\u003cli\u003eTP220 SureGrip\u003c\/li\u003e\n\u003cli\u003eInsulated Test Probe Set\u003c\/li\u003e\n\u003cli\u003eTL224 SureGrip Silicone Test Lead Set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/tl220.pdf?v=1660241906\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122154601,"sku":"FLUTL220","price":165.19,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F-tl220_02a_c_W.png?v=1660241928"},{"product_id":"fluke-twistguard™-test-leads-model-tl175","title":"Fluke TwistGuard™ Test Leads, Model TL175","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eTwist. Test. Stay Safe.\u003c\/p\u003e\n\u003cp\u003eThe Fluke TL175 TwistGuard™ Test Leads offer adjustable length test tips for use in different measurement environments. By simply twisting the test lead the user can change the exposed probe tip length from 19 mm to 4 mm (0.75 in to 0.16 in).\u003c\/p\u003e\n\u003cp\u003e“\u003cem\u003eThey work well, are very durable, and add a whole new level to safety…along with the ability to twist them to expose the entire probe for more traditional feel while testing\u003c\/em\u003e”- S.C., verified customer\u003c\/p\u003e\n\u003cp\u003eThe adjustable tip shroud meets new electrical safety requirements to reduce tip exposure while providing the versatility needed for most measurements. The correct category rating for the tip exposure being used is always visible on the test leads. This makes the TL175 test leads suitable for use in many environments:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCAT II 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWearGuard™ lead wire wear indicator makes it easier to see insulation wear and tear. If the inner, white insulation layer shows through the outer, black layer, damage is indicated, and the leads must be replaced. The silicone insulation withstands high temperatures and remains flexible in cold temperatures. While the universal input plugs are compatible with all instruments that accept standard 4 mm shrouded banana plugs.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePatented TwistGuard™ reduces tip exposure\u003c\/li\u003e\n\u003cli\u003eNew WearGuard™ silicone leads indicate when to replace leads\u003c\/li\u003e\n\u003cli\u003eHeavy-duty strain relief tested to 30,000+ bends without failure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/tl175_datasheet.pdf?v=1660327224\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/tl175_instruction_sheet.pdf?v=1660327224\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122220137,"sku":"FLUTL175","price":67.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/fluke-tl175-2.png?v=1660327270"},{"product_id":"fluke-handheld-digital-thermometer-model-51-ii","title":"Fluke Handheld Digital Thermometer, Model 51-II*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 51 II single input digital thermometer delivers fast response with laboratory accuracy (0.05% + 0.3°C). You can use the 51 II to measure contact temperature on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or E-type thermocouple temperature sensors. The user friendly-front panel and large, backlit display make it easy to view results. And the sleep mode feature preserves battery life to give you a typical thousand hours of operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle Input digital thermometer for lab, QA, process calibration, food safety and HVAC\u003c\/li\u003e\n\u003cli\u003eMeasures J, K, T, and E-type thermocouples\u003c\/li\u003e\n\u003cli\u003ePresents results in °C, °F, or Kelvin (K) on a large backlit display\u003c\/li\u003e\n\u003cli\u003eIncludes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events\u003c\/li\u003e\n\u003cli\u003eEasy-to-access battery door that allows replacing the battery without breaking the calibration seal\u003c\/li\u003e\n\u003cli\u003eComes with splash- and dust-resistant case protected by an impact-absorbing holster and a three-year warranty\u003c\/li\u003e\n\u003cli\u003ePowered by three, standard AA batteries -30-\u003c\/li\u003e\n\u003cli\u003eIncludes an electronic offset function that compensates for thermocouple errors to maximize overall accuracy\u003c\/li\u003e\n\u003cli\u003eHandles temperatures up to 900°C (1600°F)\u003c\/li\u003e\n\u003cli\u003eProvides a user-friendly front panel that is easy to set up and operate\u003c\/li\u003e\n\u003cli\u003eOffers sleep mode to increase battery life; 1000-hour battery life typical\u003c\/li\u003e\n\u003cli\u003eOffers optional ToolPak accessory to hang the thermometer from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTemperature accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAbove -100°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, E, and N-type: ±[0.05% + 0.3°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eR and S-type: ±[0.05% + 0.4°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBelow -100°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eJ, K, E, and N-types: ±[0.20% + 0.3°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eT-type: ±[0.50% + 0.3°C]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eJ-type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-210°C to 1200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-type\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1372°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-type\u003c\/td\u003e\n\u003ctd\u003e-250°C to 400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-type\u003c\/td\u003e\n\u003ctd\u003e-150°C to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN-type\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1300°C\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR and S-type\u003c\/td\u003e\n\u003ctd\u003e0°C to 1767°C\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature scale\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eITS-90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable standards\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNIST-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C, 0.1 K \u0026lt; 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003e1°C, 1 K ≥ 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"nobold small-font\"\u003e1. Only the Fluke Models 53 II B and 54 II Bthermometers are capable of measuring N, R, and S-type thermocouples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% to 90%; 0°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003e0% to 70%; 0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCE, CSA, TÜV (pending)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e173 x 86 x 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 AA batteries; typical 1000-hour life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/52_ii_users_manual.pdf?v=1660155598\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122252905,"sku":"FLUFLUKE51260HZ","price":659.39,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F_51_2_01b_h_1500x1000_1.png?v=1660159940"},{"product_id":"fluke-fused-test-probe-set-with-test-leads-model-ftpl-1","title":"Fluke Fused Test Probe Set with Test Leads, Model FTPL-1*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eSureGrip Fused Test Probe and Test Lead set with built-in replaceable fuses for additional measurement protection.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the probe fuse does blow, these fused test probes will still allow the meter to indicate live voltage, helping to prevent a possible misreading of no voltage present. These modular probes ship with the Fluke TL224 silicone test leads. Rated to CAT III 1000 V, these probes have removable tip guards for reduced probe tip exposure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt in fuses for additional measurement protection, 1000 V, 11 A with 20 kA interrupt rating\u003c\/li\u003e\n\u003cli\u003eFluke fuse part number 803293\u003c\/li\u003e\n\u003cli\u003eProbes allow indication of live voltage even with blown fuse*\u003c\/li\u003e\n\u003cli\u003e2 mm threaded probe tips include removable 4 mm spring contacts and removable insulated caps for probing closely spaced leads\u003c\/li\u003e\n\u003cli\u003eTL224 leads are right angle connector on one end and straight connector on the other with reinforced strain reliefs, 1.5 meter silicone – insulated wire resists heat and cold\u003c\/li\u003e\n\u003cli\u003eOperating temperature – 20 °C to 50 °C (-5 °F to 120 °F)\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V, 10 A rating\u003c\/li\u003e\n\u003cli\u003eOne year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*Voltage readings with blown fuse are approximate and vary with the meter impedance. Before and after each measurement, verify presence of blown fuse by checking continuity of the fused test probe. Current mode is non-functional with blown fuse.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122383977,"sku":"FLUFTPL1","price":267.39,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-ftpl-1_01a_h-1500x1000.png?v=1660159299"},{"product_id":"fluke-best-pocket-multimeter-model-107","title":"Fluke Best Pocket Multimeter, Model 107*","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 107 is a compact, palm size easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool; small enough to fit in a shirt pocket yet tough enough to withstand daily use, including a 1-meter drop test. For everyday applications where true-rms accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time. With a CAT III 600 V safety rating, you don’t need to compromise safety. The Fluke 107 offers a comfortable grip, weighs only 200 g, and is easy to carry. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt comes with a TL75 Hard Point™ Test Lead Set. It’s one pair (red, black) of 48 inch (1.22 meter) test leads with right-angle, shrouded banana plugs. The meter also includes a SmartStrap™ intelligent magnetic multi-purpose lanyard that lets you hang the Fluke 107 from any ferrous surface or support the meter at an angle for easy viewing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCan measure multiple test functions like AC\/DC voltage, AC\/DC current, resistance, capacitance, diode, frequency and duty-cycle\u003c\/li\u003e\n\u003cli\u003eEnabled with current and voltage measurement functions, in a compact size\u003c\/li\u003e\n\u003cli\u003eMeasures resistance \u0026amp; continuity to check for broken wires\u003c\/li\u003e\n\u003cli\u003eData hold and backlit display to keep you working safe and fast\u003c\/li\u003e\n\u003cli\u003eErgonomic and rugged\u003c\/li\u003e\n\u003cli\u003eComfortable grip, only weighs 200g and easy to carry\u003c\/li\u003e\n\u003cli\u003eRugged enclosure and 3.3' (1 m) drop test\u003c\/li\u003e\n\u003cli\u003eFull-parameter automatic range test, which is convenient and quick to test; at the same time, it reduces the number of rotations of the wave plate and prolongs the life of the instrument\u003c\/li\u003e\n\u003cli\u003e6000-word large screen LCD backlight display\u003c\/li\u003e\n\u003cli\u003eBattery powered, automatic power save mode\u003c\/li\u003e\n\u003cli\u003eData retention feature makes it easier to read measurement results\u003c\/li\u003e\n\u003cli\u003eCompliant with IEC61010-1 CATIII 600V overvoltage protection safety standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy is available for one year after calibration, operating from 18 °C to 28 °C and relative humidity from 0% to 75%. The format of the accuracy specification is: ± ([% of reading] + [least significant digit])\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V\u003cbr\u003e60.00 V\u003cbr\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003cbr\u003e0.01 V\u003cbr\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e0.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eExchange millivolts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e3.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDiode test\u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.000 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd\u003e10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003cbr\u003e(ohm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω\u003cbr\u003e4.000 kΩ\u003cbr\u003e40.00 kΩ\u003cbr\u003e400.0 kΩ\u003cbr\u003e4.000 MΩ\u003cbr\u003e40.00 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003cbr\u003e0.001 kΩ\u003cbr\u003e0.01 kΩ\u003cbr\u003e0.1 kΩ\u003cbr\u003e0.001 MΩ\u003cbr\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.5 % + 3\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCapacitor\u003csup\u003e3\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.00 nF\u003cbr\u003e500.0 nF\u003cbr\u003e5.000 μF\u003cbr\u003e50.00 μF\u003cbr\u003e500.0 μF\u003cbr\u003e1000 μF\u003c\/td\u003e\n\u003ctd\u003e0.01 nF\u003cbr\u003e0.1 nF\u003cbr\u003e0.001 μF\u003cbr\u003e0.01 μF\u003cbr\u003e0.1 μF\u003cbr\u003e1 μF\u003c\/td\u003e\n\u003ctd\u003e2 % + 5\u003cbr\u003e2 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFrequency\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHz\u003cbr\u003e(10 Hz – 100 kHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.00 Hz\u003cbr\u003e500.0 Hz\u003cbr\u003e5.000 kHz\u003cbr\u003e50.00 kHz\u003cbr\u003e100.0 kHz\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003cbr\u003e0.1 Hz\u003cbr\u003e0.001 kHz\u003cbr\u003e0.01 kHz\u003cbr\u003e0.1 kHz\u003c\/td\u003e\n\u003ctd\u003e0.1 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDuty cycle\u003csup\u003e4\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 % to 99 %\u003c\/td\u003e\n\u003ctd\u003e0.10 %\u003c\/td\u003e\n\u003ctd\u003e1 % typical case\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC current\u003cbr\u003e(40 Hz - 200 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.000 A\u003cbr\u003e10.00 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003cbr\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e1.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.000 A\u003cbr\u003e10.00 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003cbr\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e1.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003col\u003e\n\u003cli\u003eAll AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.\u003c\/li\u003e\n\u003cli\u003eTypically, the open circuit test voltage is 2.0 V and the short circuit current is \u0026lt; 0.6 mA.\u003c\/li\u003e\n\u003cli\u003eThe parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range).\u003c\/li\u003e\n\u003cli\u003eAll AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.\u003c\/li\u003e\n\u003cli\u003eTypically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"20%\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"20%\"\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"20%\"\u003e\u003cstrong\u003eInput impedance (nominal value)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"20%\"\u003e\u003cstrong\u003eCommon mode rejection ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"20%\"\u003e\u003cstrong\u003eNormal mode rejection ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10 MΩ \u0026lt;100 pF\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;60 dB at 50 Hz or 60 Hz at DC current\u003c\/td\u003e\n\u003ctd\u003e−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExchange millivolts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 mV\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;1M, \u0026lt;100 pF\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;80 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003ctd\u003e−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10 MΩ \u0026lt;100 pF\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100 dB at 50 Hz or 60 Hz at DC current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003col\u003e\n\u003cli\u003eUp to 6 x 105 V Hz\u003c\/li\u003e\n\u003cli\u003eFor medium voltage (alternating current), the input impedance is approximately 1 MΩ.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eGeneral technical indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eThe highest voltage applied to any terminal and ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDisplay (LCD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e6000 counts, updated three times per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eType of battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eTwo AAA batteries (NEDA 24A, IEC LR03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eBattery life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eAt least 200 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eTemperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-30 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eWorking humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eNo condensation below 10 °C\u003cbr\u003e≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eWorking humidity, 40 MΩ range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAltitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eWorking elevation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eStorage altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTemperature coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.1 X (specified accuracy) \/ °C (\u0026lt;18 °C or \u0026gt;28 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCurrent input fuse protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e11A, 1000V fast-melting type, must use Fluke designated parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVolume (height x width x length)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e142 mm x 69 mm x 28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eProtection level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eIEC 60529: IP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eIEC 61010-1: 600 V CAT III, pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eElectromagnetic environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eIEC 61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eElectromagnetic compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eApplicable only in Korea. Class A equipment (industrial broadcasting and communication equipment)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis product meets the requirements of industrial (Class A) electromagnetic wave equipment, which should be noted by the seller or user. The device is suitable for use in a work environment, not a home environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003eUser's Manual\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122449513,"sku":"FLUFLUKE107ESP","price":200.03,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/107.jpg?v=1660058508"},{"product_id":"fluke-premium-multimeter-test-lead-set-model-tl71","title":"Fluke Premium Multimeter Test Lead Set, Model TL71","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke TL71 Premium Multimeter Test Lead Set is a pair of comfort grip probes (red and black) with flexible silicone-insulated, right-angle test leads. These distinctive comfort grip probes are heat and cold resistant.\u003c\/p\u003e\n\u003cp\u003eAs with all Fluke products, these test leads undergo a battery of safety tests to be rated at:\u003cbr\u003eCAT II 1000 V, 10 A rating\u003cbr\u003eCAT III 1000 V, CAT IV 600V with protective cap\u003c\/p\u003e\n\u003cp\u003eThe WearGuard™ test lead indicator shows wear and tear easier. It exposes a contrasting color when the leads are damaged and need to be replaced. Silicone-insulated leads have superior flexibility in cold temperatures and resistance to high temperatures.\u003c\/p\u003e\n\u003cp\u003eThe Fluke TL71 Premium Test Leads are compatible with all instruments that accept standard 4 mm (0.16 in) shrouded banana connectors. Some of the compatible tools include:\u003c\/p\u003e\n\u003cp\u003eFluke 902 FC True-RMS HVAC Clamp Meter\u003cbr\u003eFluke 87V Industrial Multimeter\u003cbr\u003eFluke 115 Field Technicians Digital Multimeter\u003cbr\u003eFluke 787B ProcessMeter™\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThese test leads come with a one-year warranty.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne pair comfort grip probes with right-angle test leads\u003c\/li\u003e\n\u003cli\u003eWearGuard ™ indicator exposes contrasting color when damaged\u003c\/li\u003e\n\u003cli\u003eRecommended for µV measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Length\u003c\/td\u003e\n\u003ctd\u003e1.2 (4 ft), 2mm diameter probe tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory Rating\u003c\/td\u003e\n\u003ctd\u003eCAT II 1000 V, CAT III 1000 V, CAT IV 600 V, 10 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 55°C (-4°F to 131°F),\u003cbr\u003e90 % RH altitude: 2000 m (6,562 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/tl71_datasheet.pdf?v=1660241526\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213122646121,"sku":"FLUTL71","price":61.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F-tl71_04a_w.png?v=1660241559"},{"product_id":"fluke-suregrip™-master-accessory-set-model-tlk-225","title":"Fluke SureGrip™ Master Accessory Set, Model TLK-225*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eTest leads are an integral part of the complete measurement system. Worn out test leads can cause inaccurate readings and pose serious shock or electrocution hazard. The Fluke TLK-225 SureGrip™ Master Accessory Set with 13 items is the perfect replacement kit that provides flexibility and comfort with all SureGrip™ leads and probes in a convenient six pocket, roll up pouch.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSet includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTL224 Test Lead Set\u003c\/li\u003e\n\u003cli\u003eTP175 TwistGuard™ Test Probes\u003c\/li\u003e\n\u003cli\u003eAC285 SureGrip™ Alligator Clips\u003c\/li\u003e\n\u003cli\u003eAC220 SureGrip™ Alligator Clips\u003c\/li\u003e\n\u003cli\u003eAC280 SureGrip™ Hook Clips\u003c\/li\u003e\n\u003cli\u003eAC283 SureGrip™ Pincer Clips\u003c\/li\u003e\n\u003cli\u003eA convenient six-pocket roll up pouch\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003c\/h3\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/tlk225_datasheet.pdf?v=1660243543\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213123072105,"sku":"FLUTLK225","price":342.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-tlk225_03c_h-1500x1000.png?v=1660243567"},{"product_id":"fluke-hard-point™-test-lead-set-model-tl75","title":"Fluke Hard Point™ Test Lead Set, Model TL75","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke TL75 Hard Point™ Test Leads are a set of comfort grip, PVC-insulated probes. TL75s offer the convenience of a test lead and probe together in one unit with a variety of connections. This set of test leads are recommended for all general-purpose measurements and are compatible with a wide range of Fluke meters and tools.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke TL75 Hard Point™ Test Lead Set is CAT II 1000 V, 10 A rated. When the protective caps are placed on the leads, the ratings jump up to CAT IV 600 V, CAT III 1000 V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTest lead and probe in one unit\u003c\/li\u003e\n\u003cli\u003e48 inches (1.22 meter) long\u003c\/li\u003e\n\u003cli\u003eCAT II 1000 V, 10 A rated\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V rated with protective cap\u003c\/li\u003e\n\u003cli\u003eCSA Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213123104873,"sku":"FLUTL75","price":41.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/fluke-tl75-1.png?v=1660235850"},{"product_id":"fluke-true-rms-digital-multimeter-model-87vmax","title":"Fluke True-RMS Digital Multimeter, Model 87VMax*","description":"\u003ch3\u003eDescription \u003c\/h3\u003e\n\u003cp\u003eThe 87V MAX contains all the trusted features of the most popular digital multimeter used today, the Fluke 87V, and then some. From wet, dusty or dark environments to long days, the 87V MAX was designed to help you finish the most on a work site. It features a unique function for accurate voltage and frequency measurements on variable frequency motor drives (VFDs) and other electrically noisy equipment; using true-rms ac voltage and current for accurate measurements on non-linear signals.\u003c\/p\u003e\n\u003cp\u003eThe 87V MAX is built with an IP67 rated, industrial-strength case and a removable holster. The holster doubles as a test probe holder for easier, one-handed operation. This meter is fully waterproof and dust proof keep working reliably no matter where your job takes you.\u003c\/p\u003e\n\u003cp\u003eIndustrial-strength is no joke, the meter is designed to survive drops up to 4-meters (13 feet).\u003c\/p\u003e\n\u003cp\u003eRely on accurate measurements with the extended operating temperature range of -40 °C (for up to 20 minutes) to +55 °C.\u003c\/p\u003e\n\u003cp\u003eThe large display digits and 2-level bright, white backlight and backlit keypad buttons make for increased visibility. Along with the high resolution 19,999 count display mode allows you to read measurements easily in any work environment. This multimeter will run for up to 800 hours of battery life and offers measurement capabilities\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eup to 1000 V ac and dc and up to 10 A (20 A for 30 seconds),\u003c\/li\u003e\n\u003cli\u003efrequency to 200 kHz\u003c\/li\u003e\n\u003cli\u003emin\/max\/average recording, plus 250 μs Peak min-max to capture variations automatically or\u003c\/li\u003e\n\u003cli\u003euse the built-in thermometer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWithstands drops up to 4-meters (13 feet) with industrial strength casing and holster\u003c\/li\u003e\n\u003cli\u003eWaterproof, dustproof IP67 case for the most extreme work sites\u003c\/li\u003e\n\u003cli\u003ePremium TL175 TwistGuard™ test leads\u003c\/li\u003e\n\u003cli\u003eDouble the battery life of the 87V (up to 800 hours); backlit keys for dark environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.1 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.05% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.1 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.7% + 4) true-rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC bandwidth\u003c\/td\u003e\n\u003ctd\u003e20 kHz with low pass filter; 3 dB @ 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.1 μA to 10 A\u003cbr\u003e(20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.1 μA to 10 A\u003cbr\u003e(20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 2) true-rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω to 50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.01 nF to 9999 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.5 Hz to 199.99 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.005% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDuty cycle\u003c\/td\u003e\n\u003ctd\u003eMaximum duty cycle\u003c\/td\u003e\n\u003ctd\u003e99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% per kHz + 0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e–200.0 °C to 1090 °C\u003cbr\u003e–328.0 °F to 1994.0 °F\u003cbr\u003eexcluding probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80 BK temperature probe\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e–40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater\u003cbr\u003e–40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eConductance\u003c\/td\u003e\n\u003ctd\u003eMaximum conductance\u003c\/td\u003e\n\u003ctd\u003e60.00 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eDiagnostics and data storage\u003c\/td\u003e\n\u003ctd\u003ePeak Min\/Max\u003c\/td\u003e\n\u003ctd\u003e250 μS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin\/Max\/Avg\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading hold\/Auto (Touch) Hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative reference\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDigital\u003c\/td\u003e\n\u003ctd\u003e6000 counts updates 4\/second\u003cbr\u003e19,999 counts in high–resolution mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog bar graph\u003c\/td\u003e\n\u003ctd\u003e32 segments, updates 40\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eTwo level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow pass filter (VFD measurements)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Alert™\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSafety Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC61010-1: Pollution Degree 2\u003cbr\u003eIEC 61010-2-033: CAT IV 600 V, CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCE, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eMechanical and General Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 60529: IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree AA batteries. 800 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6.0 x 10.1 x 21.5 cm (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e698.5 g (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLimited lifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40 °C to + 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% – 90% (0 °C – 35 °C)\u003cbr\u003e0% – 70% (35 °C – 55 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/87v_user_manual.pdf?v=1660324370\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/87vmax_quick_ref.pdf?v=1660324370\"\u003eQuick Reference\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213123170409,"sku":"FLUFLUKE87VMAX","price":849.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/fluke-87v-max.png?v=1660324408"},{"product_id":"fluke-dual-probe-digital-thermometer-model-52-ii","title":"Fluke Dual Probe Digital Thermometer, Model 52 II*","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 52 II dual-input digital thermometer delivers fast response with laboratory accuracy (0.05% + 0.3°C). You can use the 52 II to measure two contact temperature inputs simultaneously on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or E-type thermocouple temperature sensors. The user friendly-front panel and large, backlit display make it easy to view results from both inputs in multiple ways. And the sleep mode feature preserves battery life to give you a typical thousand hours of operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital thermometer for lab, QA, process calibration, food safety and HVAC\u003c\/li\u003e\n\u003cli\u003eShows any combination of T1, T2, T1-T2, plus MIN, MAX, or AVG on the large backlit dual display\u003c\/li\u003e\n\u003cli\u003eFeatures fast response and laboratory accuracy (0.05% + 0.3°C)\u003c\/li\u003e\n\u003cli\u003eIncludes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events\u003c\/li\u003e\n\u003cli\u003eEasy-to-access battery door that allows replacing the battery without breaking the calibration seal\u003c\/li\u003e\n\u003cli\u003eComes with splash- and dust-resistant case protected by an impact-absorbing holster and a three-year warranty\u003c\/li\u003e\n\u003cli\u003ePowered by three, standard AA batteries -30-\u003c\/li\u003e\n\u003cli\u003eFeatures an electronic offset function that compensates for thermocouple errors to maximize overall accuracy\u003c\/li\u003e\n\u003cli\u003eMeasures J, K, T, and E-type thermocouples\u003c\/li\u003e\n\u003cli\u003eHandles temperatures up to 900°C (1600°F)\u003c\/li\u003e\n\u003cli\u003ePresents results in °C, °F, or Kelvin (K)\u003c\/li\u003e\n\u003cli\u003eProvides a user-friendly front panel that is easy to set up and operate\u003c\/li\u003e\n\u003cli\u003eOffers sleep mode to increase battery life; 1000-hour battery life typical\u003c\/li\u003e\n\u003cli\u003eOffers optional ToolPak accessory to hang the thermometer from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTemperature accuracy\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cb\u003eAbove -100°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, E, and N-type: ±[0.05% + 0.3°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR and S-type: ±[0.05% + 0.4°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cb\u003eBelow -100°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eJ, K, E, and N-types: ±[0.20% + 0.3°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-type: ±[0.50% + 0.3°C]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eJ-type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-210°C to 1200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-type\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1372°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-type\u003c\/td\u003e\n\u003ctd\u003e-250°C to 400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-type\u003c\/td\u003e\n\u003ctd\u003e-150°C to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN-type\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1300°C\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR and S-type\u003c\/td\u003e\n\u003ctd\u003e0°C to 1767°C\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature scale\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eITS-90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable standards\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNIST-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C, 0.1 K \u0026lt; 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1°C, 1 K ≥ 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003e1. Only the Fluke Models 53 II B and 54 II thermometers are capable of measuring N, R, and S-type thermocouples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% to 90%; 0°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 70%; 0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSafety Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCE, CSA, TÜV (pending)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e173 x 86 x 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 AA batteries; typical 1000-hour life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/52_ii_users_manual.pdf?v=1660155598\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213123432553,"sku":"FLUFLUKE52260HZ","price":827.39,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/fluke-52-2-02b-1500x1000.png?v=1660155603"},{"product_id":"fluke-hvac-infrared-and-contact-thermometer-model-561","title":"Fluke HVAC Infrared and Contact Thermo Meter, Model 561*","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 561 IR contact thermo meter combines the temperature measurement functions that industrial, electrical, and HVAC\/R professionals need in one tool. It is an IR thermometer for non-contact measurements, with K-type thermocouple capability for contact temperature measurement. It's fast, efficient, and easy to use, saving you valuable time and effort.\u003c\/p\u003e\n\u003cp\u003eUse the 561 IR capabilities to scan large areas or small objects quickly and efficiently, without having to shut down equipment. Measure hot, moving, electrically energized, and hard-to-reach objects instantly. Check motors, insulation, breakers, radiant heating, pipes, corroded connections, and wires. Plus, scan ducts, and other hard-to-reach objects from the floor and leave your ladder in the truck.\u003c\/p\u003e\n\u003cp\u003eYou can also use the Fluke 561's handy flexible pipe probe (included) to take super-heat or internal temperatures. Or plug in any industry standard type K mini connector thermocouple probe to take those measurements and preserve your investment in thermocouples you already own.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContact and non-contact IR thermometer for measuring up close or at a distance, without a ladder\u003c\/li\u003e\n\u003cli\u003eMeasures temperature from -40°C to 550° C (-40°F to 1022°F)\u003c\/li\u003e\n\u003cli\u003eWorks with all standard mini-connector type K thermocouples\u003c\/li\u003e\n\u003cli\u003eProvides single-point laser sighting\u003c\/li\u003e\n\u003cli\u003eAllows easy emissivity adjustment for measuring pipes and other shiny surfaces more accurately\u003c\/li\u003e\n\u003cli\u003eFeatures fabric hook-and-loop fastener pipe probe for superheat, sub-cooling, and other contact and ambient measurements\u003c\/li\u003e\n\u003cli\u003eProvides MIN, MAX, and DIF functions to help you quickly identify problems\u003c\/li\u003e\n\u003cli\u003eWeighs only 12 ounces\/340 grams) and is extremely easy to use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 550°C (-40 to 1022°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F) of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD:S (distance to spot size)\u003c\/td\u003e\n\u003ctd\u003e12:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eEasy emissivity selector\u003c\/td\u003e\n\u003ctd\u003eAdjustable with three settings:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eLow (0.3), medium (0.7). high (0.95)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay accuracy [assumes ambient operating temperature of 23°C (73°F) to 25°C (77°F)]\u003c\/td\u003e\n\u003ctd\u003e±1.0% of reading ±1% of reading or ±1°C (±2°F), whichever is greater below 0°C \/ 32°F, ±1°C (±2°F) ±0.1°\/1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e500 mSec (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e±0.5% of reading or ±1°C (±2°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral response\u003c\/td\u003e\n\u003ctd\u003e8 µm to 14 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser sighting\u003c\/td\u003e\n\u003ctd\u003eSingle point laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser shutoff\u003c\/td\u003e\n\u003ctd\u003eLaser turns off above ambient temperature of 40°C (104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser power\u003c\/td\u003e\n\u003ctd\u003eClass 2(II) operation; Output \u0026lt; 1 mW, wavelength 630-670 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH non-condensing, at \u0026lt; 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower, battery life\u003c\/td\u003e\n\u003ctd\u003e2 AA batteries (alkaline or NiCD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay hold\u003c\/td\u003e\n\u003ctd\u003e7 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklit display\u003c\/td\u003e\n\u003ctd\u003eYes, LCD with dual temperatures (current and MAX\/MIN\/DIF\/KTC), low battery, F\/C indicator, and Scan\/Hold options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C (32°F to 120°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 65°C (-25°F to 150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAX, MIN, DIF temperatures\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Type K mini adapter input\u003c\/td\u003e\n\u003ctd\u003eYes, compatible with industry standard K type probes with mini-connector. Displays to the thermometer temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Type K fabric hook-and-loop fastener pipe probe\u003c\/td\u003e\n\u003ctd\u003eYes, with a temperature range of 0°C to 100°C (32°F to 212°F) and accuracy of ±2.2°C (±4°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVAC measurement guide\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/561_brochure.PDF?v=1660236638\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/561_user_s_manual.pdf?v=1660236637\"\u003eUser's Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213123530857,"sku":"FLUFLUKE561","price":454.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/f-561_01b_1500x1000_bd5067d2-b0d6-487f-9041-56deec412e4f.png?v=1660236681"},{"product_id":"fluke-voltage-detector-pen-non-contact-voltage-tester-model-2ac","title":"Fluke Voltage Detector Pen, Non-Contact Voltage Tester, Model 2AC","description":"\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 2AC is the latest addition to the VoltAlert™ AC non-contact voltage tester family. It is designed to be pocket-sized and easy to use. The tip of the pocket-sized tester will glow red when within close proximity of an outlet, terminal strip, or power cord where voltage is present. The 2 AC is always on, with a battery check function to make sure the tester is working properly. *\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e* Use of Battery Check function is optional and for convenience only, it is not intended as a substitute for checking the unit on a known live source before and after use.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact voltage detection from 90 to 1000 V AC\u003c\/li\u003e\n\u003cli\u003eInnovative 'Battery Check' ensures battery is in good condition*\u003c\/li\u003e\n\u003cli\u003eIntegrated clip design, optimized for pocket storage\u003c\/li\u003e\n\u003cli\u003eCAT IV 1000 V overvoltage rated product for best in class user protection\u003c\/li\u003e\n\u003cli\u003eSuitable for a wide range of residential, commercial and industrial needs\u003c\/li\u003e\n\u003cli\u003eFluke ruggedness and reliability with a two-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eTechnical Information\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Principles\u003c\/td\u003e\n\u003ctd\u003eSenses the steady state electrostatic ﬁeld produced by AC voltage through insulation without requiring contact to the bare conductor. A red glow at the tip indicates the presence of voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets IEC 61010-1:2001, UL 61010-1 (2nd ed.), CAN\/CSA-C22.2 No. 61010-1-04, and ISA-82.02.01 Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eMeets IEC 61326-1:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating\u003c\/td\u003e\n\u003ctd\u003e90 V AC to 1000 V AC, CAT IV 1000 V rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature (Operating and Storage)\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C (-14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eOperating Humidity Ranges\u003c\/td\u003e\n\u003ctd\u003e0% to 95% (0°C to 30°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0% to 75% (30°C to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0% to 45% (40°C to 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e2000 m (CAT IV 1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleaning\u003c\/td\u003e\n\u003ctd\u003eClean with damp cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eTypical battery life of greater than one year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty Period\u003c\/td\u003e\n\u003ctd\u003eTwo years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/2ac_datasheet.pdf?v=1660327015\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/2ac_instruction_sheet.pdf?v=1660327015\"\u003eInstruction Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":40213123629161,"sku":"FLUFLK2AC901000V","price":71.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/products\/F-2ac_05a_w.png?v=1660327055"},{"product_id":"fluke-15b-digital-multimeter-model-fluke-15b-esp","title":"Fluke 15B+ Digital Multimeter, Model FLUKE-15B+ ESP*","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 302+ is a compact, easy-to-use digital clamp meter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where True-RMS accuracy isn’t needed, the Fluke 302+ delivers reliable measurements time after time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 302+ Additional Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Fluke 302+ CAT III Digital Clamp Meter is more compact, making the use of clamp-type ammeter more flexible and simpler\u003c\/li\u003e\n\u003cli\u003eMeasure AC current up to 400A\u003c\/li\u003e\n\u003cli\u003e30 mm large jaw\u003c\/li\u003e\n\u003cli\u003eHigh accuracy of 1.8%\u003c\/li\u003e\n\u003cli\u003eBacklit display\u003c\/li\u003e\n\u003cli\u003eTwo-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 302+ Comes with Fluke TL75 Hard Point™ Test Lead Set\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne pair (red, black) of comfort grip probes\u003c\/li\u003e\n\u003cli\u003e48 inches (1.22 meter) PVC insulated test leads with right-angle shrouded banana plugs\u003c\/li\u003e\n\u003cli\u003eRecommended for general purpose measurements\u003c\/li\u003e\n\u003cli\u003eCAT II 1000 V, 10 A rating\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V only with protective cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 302+ Safety Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeets CAT IV 300V\/CAT ||| 600V safety rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC current measurements up to 400 A, handling your everyday electrical maintenance needs\u003c\/li\u003e\n\u003cli\u003eComes with the TL75 Hard Point™ Test Lead Set offering the convenience of a test lead and probe in one unit with a variety of connections\u003c\/li\u003e\n\u003cli\u003eRugged, easy-to-use digital clamp meter with CAT IV 300 V\/CAT III 600 V safety rating\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTechnical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" width=\"25%\"\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.8% ±5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400\/600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ±5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400\/600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ±5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDC mV range\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% ±5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤ 70 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBacklight display\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eH x W x D (mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e208 x 58.5 x 28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw size\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0 ~ 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eScreen refresh rate\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 2 times \/ sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTest leads\u003c\/td\u003e\n\u003ctd\u003eTL75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e2 AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eDocument\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/flk-240133-en-global-15B-plus-17B-plus-ds-w.pdf?v=1721326626\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/usermanual.pdf?v=1721326901\"\u003eUser Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/calibrationmanual.pdf?v=1721326902\"\u003eCalibration Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/safety_information.pdf?v=1721326900\"\u003eSafety Information\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/quick_ref.pdf?v=1721326902\"\u003eQuick Ref\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41733572067433,"sku":"FLUFLUKE15B+ESP","price":184.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/F_15b_2B_01a_h_1500x1000_1.png?v=1721327002"},{"product_id":"fluke-301d-ac-dc-clamp-meter","title":"Fluke 301D AC\/DC Clamp Meter","description":"\u003ch3\u003eGeneral Description\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 301D Series AC\/DC Clamp Meter is designed with a lightweight and compact body, which allows you to carry it around in your pocket. The slim and thin jaw can easily fit into tightly packed wires. The Fluke 301D test current, voltage, resistance, continuity, frequency (voltage and current), capacitance, and diode, etc.. You can handle multiple test needs with just one tool. With the AC\/DC function, it can be applied to more application scenarios requiring DC testing, such as new energy of PV and wind power, new energy vehicles, communications, data centers, etc..\u003cbr\u003e\u003cbr\u003eBenefits\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe body weighs only 154g and is 16mm thick, which is light and portable and can be put into a pocket\u003c\/li\u003e\n\u003cli\u003eThe slim and thin jaw of only 10mm can easily fit into tightly packed wires\u003c\/li\u003e\n\u003cli\u003e600A AC\/DC range (D model), 0.01A high resolution\u003c\/li\u003e\n\u003cli\u003eTests voltage, resistance and continuity\u003c\/li\u003e\n\u003cli\u003eTests current frequency and voltage frequency\u003c\/li\u003e\n\u003cli\u003eTests capacitance and diodes\u003c\/li\u003e\n\u003cli\u003eBacklight\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":53859096199540,"sku":"FLUFLUKE301D","price":223.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0083\/4328\/9961\/files\/Fluke301DACDCClampMeter3.webp?v=1769399674"}],"url":"https:\/\/orka.ca\/collections\/black-friday-2026-fluke.oembed","provider":"Orka","version":"1.0","type":"link"}